Literature DB >> 12773687

Three-dimensional CT angiography of the hepatic artery: use of multi-detector row helical CT and a contrast agent.

Masato Tanikake1, Tadafumi Shimizu, Isamu Narabayashi, Mitsuru Matsuki, Kiyohiro Masuda, Kazuhiro Yamamoto, Yasuo Uesugi, Shushi Yoshikawa.   

Abstract

The administration of a contrast agent to obtain optimal images at three-dimensional computed tomographic (CT) angiography of the hepatic artery by using multi-detector row helical CT was investigated. Three-dimensional CT angiographic images were evaluated visually, and quantitative evaluation was performed by measuring the postcontrast CT number of the aorta. The injection rate of 5 mL/sec was significantly superior to that of 4 mL/sec in both evaluations. At administration of a contrast agent with 300 or 350 milligrams of iodine per milliliter, there were no significant differences in either evaluations. The preferable injection rate to obtain sufficient three-dimensional CT angiographic data was 5 mL/sec.

Entities:  

Mesh:

Substances:

Year:  2003        PMID: 12773687     DOI: 10.1148/radiol.2273011964

Source DB:  PubMed          Journal:  Radiology        ISSN: 0033-8419            Impact factor:   11.105


  12 in total

1.  Three-dimensional reconstruction of a fibro-osseous lesion using binary images transformed from histopathological images.

Authors:  M Araki; S Kawashima; N Matsumoto; S Nishimura; T Ishii; K Komiyama; K Honda
Journal:  Dentomaxillofac Radiol       Date:  2010-05       Impact factor: 2.419

2.  Evaluation of a method for improving the detection of hepatocellular carcinoma.

Authors:  Edgar Bendik; Peter B Noël; Daniela Münzel; Alexander A Fingerle; Martin Henninger; Christian Markus; Alain Vlassenbroek; Ernst J Rummeny; Martin Dobritz
Journal:  Eur Radiol       Date:  2013-09-03       Impact factor: 5.315

3.  Aorto-iliac multidetector-row CT angiography with low kV settings: improved vessel enhancement and simultaneous reduction of radiation dose.

Authors:  B Wintersperger; T Jakobs; P Herzog; S Schaller; K Nikolaou; C Suess; C Weber; M Reiser; C Becker
Journal:  Eur Radiol       Date:  2004-12-21       Impact factor: 5.315

4.  Initial experience with single-source dual-energy CT abdominal angiography and comparison with single-energy CT angiography: image quality, enhancement, diagnosis and radiation dose.

Authors:  Daniella F Pinho; Naveen M Kulkarni; Arun Krishnaraj; Sanjeeva P Kalva; Dushyant V Sahani
Journal:  Eur Radiol       Date:  2012-08-25       Impact factor: 5.315

5.  Impact of Multidetector CT on 3D CT Angiography.

Authors:  I K Indrajit; J D Souza; V S Bedi; R Pant
Journal:  Med J Armed Forces India       Date:  2011-07-21

6.  Anatomic variations of arterial liver vascularization: an analysis by using MDCTA.

Authors:  Luca Saba; Giorgio Mallarini
Journal:  Surg Radiol Anat       Date:  2011-01-20       Impact factor: 1.246

7.  Development of a noise reduction filter algorithm for pediatric body images in multidetector CT.

Authors:  Eiji Nishimaru; Katsuhiro Ichikawa; Izumi Okita; Yukihiro Tomoshige; Takehiro Kurokawa; Yuko Nakamura; Masayuki Suzuki
Journal:  J Digit Imaging       Date:  2009-06-18       Impact factor: 4.056

8.  Establishing models of portal vein occlusion and evaluating value of multi-slice CT in hepatic VX2 tumor in rabbits.

Authors:  Yue-Yong Qi; Li-Guang Zou; Ping Liang; Dong Zhang
Journal:  World J Gastroenterol       Date:  2007-06-28       Impact factor: 5.742

Review 9.  Detection and characterization of benign focal liver lesions with multislice CT.

Authors:  J T Winterer; E Kotter; N Ghanem; M Langer
Journal:  Eur Radiol       Date:  2006-05-25       Impact factor: 7.034

10.  Double-low protocol for hepatic dynamic CT scan: Effect of low tube voltage and low-dose iodine contrast agent on image quality.

Authors:  Xiuli Zhang; Shaodong Li; Wenlou Liu; Ning Huang; Jingjing Li; Li Cheng; Kai Xu
Journal:  Medicine (Baltimore)       Date:  2016-06       Impact factor: 1.889