Literature DB >> 19532002

Reliability of low-radiation dose CT in the assessment of screw placement after posterior scoliosis surgery, evaluated with a new grading system.

Kasim Abul-Kasim1, Anita Strömbeck, Acke Ohlin, Pavel Maly, Pia C Sundgren.   

Abstract

STUDY
DESIGN: A retrospective study.
OBJECTIVE: To evaluate the reliability of computed tomography (CT) with low radiation dose in the assessment of implant status in patients with adolescent idiopathic scoliosis (AIS). SUMMARY OF BACKGROUND DATA: The use of all-pedicle screw construct in scoliosis corrective surgery continues to gain increasing popularity since their introduction 1994 although their use in the thoracic spine carries a potential risk for neurovascular complications. CT is the method widely used to evaluate screw placement.
METHODS: Retrospective analysis of 46 consecutive low-dose spine CT in patients with AIS after posterior corrective surgery. Status of 809 titanium screws (642 thoracic) was evaluated. The degree of interobserver and intraobserver agreements about implant status was used as an indicator of the reliability of the low-dose spine CT in the assessment of accuracy of pedicle screw insertion. A new grading system has been developed for this purpose. Five types of misplacement have been evaluated: lateral, medial, and anterior cortical perforations; endplate perforation; and foraminal perforation.
RESULTS: The analysis has shown a substantial interobserver and intraobserver agreements (kappa: 0.69 and 0.76, respectively) in differentiating pedicle screws with acceptable placement from screws with partial or total cortical perforation. None of the examinations was subjectively classified as unreliable.
CONCLUSION: The study has shown that low-dose spine CT is a reliable method in evaluating screw placement in patients with AIS after posterior scoliosis surgery with titanium implants, using the here proposed grading system. The new grading system of screw misplacement was feasible and in line with the general agreement about the harmlessness of misplacement with minor pedicle breach. The reliability of low-dose spine CT in evaluation of lateral and medial cortical perforations was substantial. To reduce the radiation load, the postoperative assessment of titanium implants should be performed with low-dose CT.

Entities:  

Mesh:

Year:  2009        PMID: 19532002     DOI: 10.1097/BRS.0b013e31819b22a4

Source DB:  PubMed          Journal:  Spine (Phila Pa 1976)        ISSN: 0362-2436            Impact factor:   3.468


  15 in total

1.  Minimally invasive scoliosis surgery: an innovative technique in patients with adolescent idiopathic scoliosis.

Authors:  Vishal Sarwahi; Adam L Wollowick; Etan P Sugarman; Jonathan J Horn; Melanie Gambassi; Terry D Amaral
Journal:  Scoliosis       Date:  2011-08-11

2.  Use of computed tomographic reconstruction to establish the ideal entry point for pedicle screws in idiopathic scoliosis.

Authors:  Peiqiang Su; Wentong Zhang; Yan Peng; Anjing Liang; Kaili Du; Dongsheng Huang
Journal:  Eur Spine J       Date:  2011-08-13       Impact factor: 3.134

3.  Radiological and clinical outcome of screw placement in adolescent idiopathic scoliosis: evaluation with low-dose computed tomography.

Authors:  Kasim Abul-Kasim; Acke Ohlin; Anita Strömbeck; Pavel Maly; Pia C Sundgren
Journal:  Eur Spine J       Date:  2009-11-04       Impact factor: 3.134

4.  CT-navigation versus fluoroscopy-guided placement of pedicle screws at the thoracolumbar spine: single center experience of 4,500 screws.

Authors:  Albrecht Waschke; Jan Walter; Pedro Duenisch; Rupert Reichart; Rolf Kalff; Christian Ewald
Journal:  Eur Spine J       Date:  2012-09-23       Impact factor: 3.134

Review 5.  [Imaging of non-traumatic spinal diseases in children].

Authors:  G Pärtan; R Eyb; G Artacker
Journal:  Radiologe       Date:  2010-12       Impact factor: 0.635

Review 6.  Pedicle screw loosening: a clinically relevant complication?

Authors:  Fabio Galbusera; David Volkheimer; Sandra Reitmaier; Nikolaus Berger-Roscher; Annette Kienle; Hans-Joachim Wilke
Journal:  Eur Spine J       Date:  2015-01-24       Impact factor: 3.134

7.  The "slide technique": an improvement on the "funnel technique" for safe pedicle screw placement in the thoracic spine.

Authors:  Raphaël Vialle; Reinhard Zeller; Robert W Gaines
Journal:  Eur Spine J       Date:  2014-05-14       Impact factor: 3.134

8.  Dose optimisation for intraoperative cone-beam flat-detector CT in paediatric spinal surgery.

Authors:  Asger Greval Petersen; Søren Eiskjær; Jon Kaspersen
Journal:  Pediatr Radiol       Date:  2012-06-06

9.  Technical aspects of CT imaging of the spine.

Authors:  Bernhard Tins
Journal:  Insights Imaging       Date:  2010-10-21

10.  The rate of screw misplacement in segmental pedicle screw fixation in adolescent idiopathic scoliosis.

Authors:  Kasim Abul-Kasim; Acke Ohlin
Journal:  Acta Orthop       Date:  2010-12-29       Impact factor: 3.717

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.