Literature DB >> 19526517

Accuracy and precision of MR blood oximetry based on the long paramagnetic cylinder approximation of large vessels.

Michael C Langham1, Jeremy F Magland, Charles L Epstein, Thomas F Floyd, Felix W Wehrli.   

Abstract

An accurate noninvasive method to measure the hemoglobin oxygen saturation (%HbO(2)) of deep-lying vessels without catheterization would have many clinical applications. Quantitative MRI may be the only imaging modality that can address this difficult and important problem. MR susceptometry-based oximetry for measuring blood oxygen saturation in large vessels models the vessel as a long paramagnetic cylinder immersed in an external field. The intravascular magnetic susceptibility relative to surrounding muscle tissue is a function of oxygenated hemoglobin (HbO(2)) and can be quantified with a field-mapping pulse sequence. In this work, the method's accuracy and precision was investigated theoretically on the basis of an analytical expression for the arbitrarily oriented cylinder, as well as experimentally in phantoms and in vivo in the femoral artery and vein at 3T field strength. Errors resulting from vessel tilt, noncircularity of vessel cross-section, and induced magnetic field gradients were evaluated and methods for correction were designed and implemented. Hemoglobin saturation was measured at successive vessel segments, differing in geometry, such as eccentricity and vessel tilt, but constant blood oxygen saturation levels, as a means to evaluate measurement consistency. The average standard error and coefficient of variation of measurements in phantoms were <2% with tilt correction alone, in agreement with theory, suggesting that high accuracy and reproducibility can be achieved while ignoring noncircularity for tilt angles up to about 30 degrees . In vivo, repeated measurements of %HbO(2) in the femoral vessels yielded a coefficient of variation of less than 5%. In conclusion, the data suggest that %HbO(2) can be measured reproducibly in vivo in large vessels of the peripheral circulation on the basis of the paramagnetic cylinder approximation of the incremental field. (c) 2009 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19526517      PMCID: PMC2753239          DOI: 10.1002/mrm.21981

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  21 in total

1.  Water proton MR properties of human blood at 1.5 Tesla: magnetic susceptibility, T(1), T(2), T*(2), and non-Lorentzian signal behavior.

Authors:  W M Spees; D A Yablonskiy; M C Oswood; J J Ackerman
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

2.  Changes in muscle water and composition induced by protein depletion in rat at two environmental temperatures.

Authors:  D M Hegsted; J P Milner; D Wilson; P Ginna
Journal:  Am J Physiol       Date:  1953-01

3.  In vivo measurement of blood oxygen saturation using magnetic resonance imaging: a direct validation of the blood oxygen level-dependent concept in functional brain imaging.

Authors:  E M Haacke; S Lai; J R Reichenbach; K Kuppusamy; F G Hoogenraad; H Takeichi; W Lin
Journal:  Hum Brain Mapp       Date:  1997       Impact factor: 5.038

4.  MR susceptometry for measuring global brain oxygen extraction.

Authors:  María A Fernández-Seara; Aranee Techawiboonwong; John A Detre; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2006-05       Impact factor: 4.668

5.  Quantitative ultrasonographic studies of lower extremity flow velocities in health and disease.

Authors:  A Fronek; M Coel; E F Berstein
Journal:  Circulation       Date:  1976-06       Impact factor: 29.690

6.  1991 I.I. Rabi Award. Estimating oxygen saturation of blood in vivo with MR imaging at 1.5 T.

Authors:  G A Wright; B S Hu; A Macovski
Journal:  J Magn Reson Imaging       Date:  1991 May-Jun       Impact factor: 4.813

7.  Blood oxygen saturation assessment in vivo using T2* estimation.

Authors:  D Li; Y Wang; D J Waight
Journal:  Magn Reson Med       Date:  1998-05       Impact factor: 4.668

8.  Oxygenation dependence of the transverse relaxation time of water protons in whole blood at high field.

Authors:  K R Thulborn; J C Waterton; P M Matthews; G K Radda
Journal:  Biochim Biophys Acta       Date:  1982-02-02

9.  Red blood cell magnetophoresis.

Authors:  Maciej Zborowski; Graciela R Ostera; Lee R Moore; Sarah Milliron; Jeffrey J Chalmers; Alan N Schechter
Journal:  Biophys J       Date:  2003-04       Impact factor: 4.033

10.  Monitoring blood oxygen state in muscle microcirculation with transverse relaxation.

Authors:  J A Stainsby; G A Wright
Journal:  Magn Reson Med       Date:  2001-04       Impact factor: 4.668

View more
  35 in total

1.  Investigating the magnetic susceptibility properties of fresh human blood for noninvasive oxygen saturation quantification.

Authors:  Varsha Jain; Osheiza Abdulmalik; Kathleen Joy Propert; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-12-08       Impact factor: 4.668

2.  Transcranial imaging of functional cerebral hemodynamic changes in single blood vessels using in vivo photoacoustic microscopy.

Authors:  Lun-De Liao; Chin-Teng Lin; Yen-Yu I Shih; Timothy Q Duong; Hsin-Yi Lai; Po-Hsun Wang; Robby Wu; Siny Tsang; Jyh-Yeong Chang; Meng-Lin Li; You-Yin Chen
Journal:  J Cereb Blood Flow Metab       Date:  2012-04-04       Impact factor: 6.200

3.  MRI estimation of global brain oxygen consumption rate.

Authors:  Varsha Jain; Michael C Langham; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2010-04-21       Impact factor: 6.200

4.  Blood oxygen level dependent angiography (BOLDangio) and its potential applications in cancer research.

Authors:  Kejia Cai; Adam Shore; Anup Singh; Mohammad Haris; Teruyuki Hiraki; Prianka Waghray; Damodar Reddy; Joel H Greenberg; Ravinder Reddy
Journal:  NMR Biomed       Date:  2012-02-02       Impact factor: 4.044

5.  Quantitative oxygenation venography from MRI phase.

Authors:  Audrey P Fan; Berkin Bilgic; Louis Gagnon; Thomas Witzel; Himanshu Bhat; Bruce R Rosen; Elfar Adalsteinsson
Journal:  Magn Reson Med       Date:  2013-09-04       Impact factor: 4.668

Review 6.  Susceptibility-based time-resolved whole-organ and regional tissue oximetry.

Authors:  Felix W Wehrli; Audrey P Fan; Zachary B Rodgers; Erin K Englund; Michael C Langham
Journal:  NMR Biomed       Date:  2016-02-26       Impact factor: 4.044

7.  Rapid magnetic resonance measurement of global cerebral metabolic rate of oxygen consumption in humans during rest and hypercapnia.

Authors:  Varsha Jain; Michael C Langham; Thomas F Floyd; Gaurav Jain; Jeremy F Magland; Felix W Wehrli
Journal:  J Cereb Blood Flow Metab       Date:  2011-04-20       Impact factor: 6.200

8.  An improved method for susceptibility and radius quantification of cylindrical objects from MRI.

Authors:  Ching-Yi Hsieh; Yu-Chung N Cheng; Jaladhar Neelavalli; E Mark Haacke; R Jason Stafford
Journal:  Magn Reson Imaging       Date:  2015-01-26       Impact factor: 2.546

9.  In vivo whole-blood T2 versus HbO2 calibration by modulating blood oxygenation level in the femoral vein through intermittent cuff occlusion.

Authors:  Michael C Langham; Ana E Rodríguez-Soto; Nadav Schwartz; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2017-09-03       Impact factor: 4.668

Review 10.  Time-resolved MRI oximetry for quantifying CMRO(2) and vascular reactivity.

Authors:  Felix W Wehrli; Zachary B Rodgers; Varsha Jain; Michael C Langham; Cheng Li; Daniel J Licht; Jeremy Magland
Journal:  Acad Radiol       Date:  2014-02       Impact factor: 3.173

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.