Literature DB >> 11283995

Monitoring blood oxygen state in muscle microcirculation with transverse relaxation.

J A Stainsby1, G A Wright.   

Abstract

Oxygen uptake from the microcirculation is a direct measure of tissue function. Magnetic resonance is capable of detecting differences between oxygenated and deoxygenated blood due to the paramagnetic properties of deoxyhemoglobin. At the level of the microcirculation, however, imaging methods cannot directly visualize the vessels. Instead, bulk MR parameters are investigated for their ability to monitor blood oxygen saturation (%O(2)) changes in the microcirculation of tissue, specifically skeletal muscle. Experiments in an in vitro model verified the feasibility of detecting changes in exponential decay signals, and also verified the prediction of only two distinct decay components. Experiments in a rabbit model demonstrate that T(2)' and monoexponential T(2) decay are not sensitive to blood oxygen changes, but that the long-T(2) component in a biexponential fit is correlated to the blood oxygen state. Assuming a two-pool model for water protons in muscle, and with knowledge of the T(2)-%O(2) relation, estimates of the microcirculation blood oxygen state can be made with some reasonable assumptions. Magn Reson Med 45:662-672, 2001. Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Substances:

Year:  2001        PMID: 11283995     DOI: 10.1002/mrm.1089

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  4 in total

1.  Accuracy of the cylinder approximation for susceptometric measurement of intravascular oxygen saturation.

Authors:  Cheng Li; Michael C Langham; Charles L Epstein; Jeremy F Magland; Jue Wu; James Gee; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2011-08-19       Impact factor: 4.668

2.  Myocardial blood flow is the dominant factor influencing cardiac magnetic resonance adenosine stress T2.

Authors:  Jill J Weyers; Venkat Ramanan; Ahsan Javed; Jennifer Barry; Melissa Larsen; Krishna Nayak; Graham A Wright; Nilesh R Ghugre
Journal:  NMR Biomed       Date:  2021-11-17       Impact factor: 4.044

3.  Calculating T2 in images from a phased array receiver.

Authors:  Peter A Hardy; Anders H Andersen
Journal:  Magn Reson Med       Date:  2009-04       Impact factor: 4.668

4.  Accuracy and precision of MR blood oximetry based on the long paramagnetic cylinder approximation of large vessels.

Authors:  Michael C Langham; Jeremy F Magland; Charles L Epstein; Thomas F Floyd; Felix W Wehrli
Journal:  Magn Reson Med       Date:  2009-08       Impact factor: 4.668

  4 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.