Abstract

In vivo diffusion tensor imaging (DTI) of rat cervical and thoracic spinal cord was performed using a three-element phased array coil at 7 T. The magnetic field was shimmed over the spinal cord in real time using an in-house developed automatic algorithm. Echo planar imaging (EPI)-based diffusion-weighted images (DWIs) were acquired with 21 gradient encoding directions. The DWIs were tensor encoded, and diffusion tensor metrics, fractional anisotropy (FA), mean diffusivity (MD), longitudinal diffusivity (lambda(0)) and transverse diffusivity (lambda( perpendicular)) were determined for both white matter (WM) and gray matter (GM). The results on six normal rats indicated no significant differences in the diffusion tensor metrics between thoracic and cervical regions. However, the DTI-derived metrics in cervical spinal cord from our study are somewhat different from the published results in rats. The possible reasons for these differences are suggested.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19520537      PMCID: PMC2763029          DOI: 10.1016/j.mri.2009.05.002

Source DB:  PubMed          Journal:  Magn Reson Imaging        ISSN: 0730-725X            Impact factor:   2.546


  28 in total

1.  Comparison of gradient encoding schemes for diffusion-tensor MRI.

Authors:  K M Hasan; D L Parker; A L Alexander
Journal:  J Magn Reson Imaging       Date:  2001-05       Impact factor: 4.813

2.  SENSE: sensitivity encoding for fast MRI.

Authors:  K P Pruessmann; M Weiger; M B Scheidegger; P Boesiger
Journal:  Magn Reson Med       Date:  1999-11       Impact factor: 4.668

3.  Simultaneous correction of ghost and geometric distortion artifacts in EPI using a multiecho reference scan.

Authors:  V J Schmithorst; B J Dardzinski; S K Holland
Journal:  IEEE Trans Med Imaging       Date:  2001-06       Impact factor: 10.048

4.  In vivo magnetic resonance microscopy of rat spinal cord at 7 T using implantable RF coils.

Authors:  M Bilgen; I Elshafiey; P A Narayana
Journal:  Magn Reson Med       Date:  2001-12       Impact factor: 4.668

5.  Generalized autocalibrating partially parallel acquisitions (GRAPPA).

Authors:  Mark A Griswold; Peter M Jakob; Robin M Heidemann; Mathias Nittka; Vladimir Jellus; Jianmin Wang; Berthold Kiefer; Axel Haase
Journal:  Magn Reson Med       Date:  2002-06       Impact factor: 4.668

6.  Fast, automated, N-dimensional phase-unwrapping algorithm.

Authors:  Mark Jenkinson
Journal:  Magn Reson Med       Date:  2003-01       Impact factor: 4.668

7.  Regularized higher-order in vivo shimming.

Authors:  Dong-Hyun Kim; Elfar Adalsteinsson; Gary H Glover; Daniel M Spielman
Journal:  Magn Reson Med       Date:  2002-10       Impact factor: 4.668

8.  Computation of the fractional anisotropy and mean diffusivity maps without tensor decoding and diagonalization: Theoretical analysis and validation.

Authors:  Khader M Hasan; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2003-09       Impact factor: 4.668

9.  The NMR phased array.

Authors:  P B Roemer; W A Edelstein; C E Hayes; S P Souza; O M Mueller
Journal:  Magn Reson Med       Date:  1990-11       Impact factor: 4.668

10.  Three-element phased-array coil for imaging of rat spinal cord at 7T.

Authors:  Kishore V Mogatadakala; James A Bankson; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

View more
  5 in total

1.  Comprehensive locomotor outcomes correlate to hyperacute diffusion tensor measures after spinal cord injury in the adult rat.

Authors:  Joong H Kim; Sheng-Kwei Song; Darlene A Burke; David S K Magnuson
Journal:  Exp Neurol       Date:  2011-11-19       Impact factor: 5.330

2.  Diffusion tensor imaging of the mouse brainstem and cervical spinal cord.

Authors:  Joong Hee Kim; Sheng-Kwei Song
Journal:  Nat Protoc       Date:  2013-02       Impact factor: 13.491

3.  Serial Diffusion Tensor Imaging In Vivo Predicts Long-Term Functional Recovery and Histopathology in Rats following Different Severities of Spinal Cord Injury.

Authors:  Samir P Patel; Taylor D Smith; Jenna L VanRooyen; David Powell; David H Cox; Patrick G Sullivan; Alexander G Rabchevsky
Journal:  J Neurotrauma       Date:  2016-02-11       Impact factor: 5.269

4.  Ex vivo diffusion tensor imaging of spinal cord injury in rats of varying degrees of severity.

Authors:  Michael B Jirjis; Shekar N Kurpad; Brian D Schmit
Journal:  J Neurotrauma       Date:  2013-08-09       Impact factor: 5.269

5.  Comparison of Diffusion MRI Acquisition Protocols for the In Vivo Characterization of the Mouse Spinal Cord: Variability Analysis and Application to an Amyotrophic Lateral Sclerosis Model.

Authors:  Matteo Figini; Alessandro Scotti; Stefania Marcuzzo; Silvia Bonanno; Francesco Padelli; Victoria Moreno-Manzano; José Manuel García-Verdugo; Pia Bernasconi; Renato Mantegazza; Maria Grazia Bruzzone; Ileana Zucca
Journal:  PLoS One       Date:  2016-08-25       Impact factor: 3.240

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.