Literature DB >> 11746595

In vivo magnetic resonance microscopy of rat spinal cord at 7 T using implantable RF coils.

M Bilgen1, I Elshafiey, P A Narayana.   

Abstract

An inductively coupled implanted coil was designed for high-resolution magnetic resonance (MR) studies of rat spinal cord (SC) in vivo at 7 T. The practical issues involved in implementation of the coil at high fields are discussed, and the adjustment of various parameters for optimizing coil performance are described. The utility of the coil was demonstrated with anatomical, magnetization transfer, diffusion tensor imaging, and proton MR spectroscopy (MRS). Copyright 2001 Wiley-Liss, Inc.

Entities:  

Mesh:

Year:  2001        PMID: 11746595     DOI: 10.1002/mrm.1325

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  10 in total

1.  High-resolution vascular imaging of the rat spine using liposomal blood pool MR agent.

Authors:  K B Ghaghada; K H J Bockhorst; S Mukundan; A V Annapragada; P A Narayana
Journal:  AJNR Am J Neuroradiol       Date:  2007-01       Impact factor: 3.825

2.  High-resolution MR imaging of the rat spinal cord in vivo in a wide-bore magnet at 17.6 Tesla.

Authors:  V C Behr; T Weber; T Neuberger; M Vroemen; N Weidner; U Bogdahn; A Haase; P M Jakob; C Faber
Journal:  MAGMA       Date:  2004-10-23       Impact factor: 2.310

3.  In vivo intermolecular zero-quantum coherence MR spectroscopy in the rat spinal cord at 17.6 T: a feasibility study.

Authors:  David Z Balla; Cornelius Faber
Journal:  MAGMA       Date:  2007-09-18       Impact factor: 2.310

4.  Neuronal and axonal degeneration in experimental spinal cord injury: in vivo proton magnetic resonance spectroscopy and histology.

Authors:  Junchao Qian; Juan J Herrera; Ponnada A Narayana
Journal:  J Neurotrauma       Date:  2010-03       Impact factor: 5.269

5.  Measurement of arterial input function of 17O water tracer in rat carotid artery by using a region-defined (REDE) implanted vascular RF coil.

Authors:  Xiaoliang Zhang; Xiao-Hong Zhu; Runxia Tian; Yi Zhang; Hellmut Merkle; Wei Chen
Journal:  MAGMA       Date:  2003-07-04       Impact factor: 2.310

Review 6.  Engineering novel detectors and sensors for MRI.

Authors:  Chunqi Qian; Gary Zabow; Alan Koretsky
Journal:  J Magn Reson       Date:  2012-11-29       Impact factor: 2.229

7.  Three-element phased-array coil for imaging of rat spinal cord at 7T.

Authors:  Kishore V Mogatadakala; James A Bankson; Ponnada A Narayana
Journal:  Magn Reson Med       Date:  2008-12       Impact factor: 4.668

8.  In vivo diffusion tensor imaging of thoracic and cervical rat spinal cord at 7 T.

Authors:  Kishore V Mogatadakala; Ponnada A Narayana
Journal:  Magn Reson Imaging       Date:  2009-06-10       Impact factor: 2.546

9.  Comprehensive small animal imaging strategies on a clinical 3 T dedicated head MR-scanner; adapted methods and sequence protocols in CNS pathologies.

Authors:  Deepu R Pillai; Robin M Heidemann; Praveen Kumar; Nagesh Shanbhag; Titus Lanz; Michael S Dittmar; Beatrice Sandner; Christoph P Beier; Norbert Weidner; Mark W Greenlee; Gerhard Schuierer; Ulrich Bogdahn; Felix Schlachetzki
Journal:  PLoS One       Date:  2011-02-07       Impact factor: 3.240

10.  A comparison of Lenz lenses and LC resonators for NMR signal enhancement.

Authors:  Mazin Jouda; Robert Kamberger; Jochen Leupold; Nils Spengler; Jürgen Hennig; Oliver Gruschke; Jan G Korvink
Journal:  Concepts Magn Reson Part B Magn Reson Eng       Date:  2017-11-21       Impact factor: 1.176

  10 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.