Literature DB >> 19520342

Characterization of hyperintense plaque with noncontrast T(1)-weighted cardiac magnetic resonance coronary plaque imaging: comparison with multislice computed tomography and intravascular ultrasound.

Tomohiro Kawasaki1, Shoichi Koga, Nobuhiko Koga, Teruo Noguchi, Hidenori Tanaka, Hisashi Koga, Takeshi Serikawa, Yoshiya Orita, Shinsuke Ikeda, Takahiro Mito, Yoshitaka Goto, Yoshiaki Shintani, Atsushi Tanaka, Takaya Fukuyama.   

Abstract

OBJECTIVES: This study sought to characterize coronary hyperintense plaques (HIP) using noncontrast T(1)-weighted imaging (T1WI) in cardiac magnetic resonance, which was then compared with multislice computed tomography and intravascular ultrasound.
BACKGROUND: Carotid plaque components such as intraplaque hemorrhages and/or lipid-rich necrotic cores can be detected as HIP by noncontrast T1WI. Although coronary HIPs have been successfully detected using this technique, the properties of hyperintense signals in coronary plaques have not yet been systematically evaluated.
METHODS: Thirty-eight lesions from 37 patients with angina pectoris who demonstrated >70% coronary stenosis on multislice computed tomography were evaluated by noncontrast T1WI using a 1.5-T magnetic resonance imager, and 25 lesions were evaluated by intravascular ultrasound. Signal intensity of coronary plaque to cardiac muscle ratio >1.0 was defined as HIP. We divided 25 lesions into the 2 groups, according to the presence or absence of HIP: HIP (n = 18) and non-HIP (n = 7) groups.
RESULTS: In comparison with the non-HIP group, the HIP group demonstrated significantly higher coronary plaque to cardiac muscle ratio (1.7 +/- 0.7 vs. 0.9 +/- 0.1, p < 0.01), higher frequency of positive remodeling as observed by both multislice computed tomography (89% vs. 0%, p<0.0001) and intravascular ultrasound (94% vs. 14%, p < 0.001) and ultrasound attenuation (100% vs. 14.3%, p < 0.0001). The frequency of spotty calcification tended to be higher in HIP (89% vs. 50%, p = 0.079). The HIP group also exhibited a significantly lower computed tomography density (-23.2 +/- 20.7 Hounsfield units [HU] vs. 9.6 +/- 20.5 HU, p < 0.01). In addition, the incidence of transient slow-flow phenomena was significantly higher in the HIP group than in the non-HIP group (83% vs. 14%, p < 0.01).
CONCLUSIONS: The typical HIP case was associated with ultrasound attenuation, positive remodeling, remarkably low computed tomography density, and a high incidence of slow-flow phenomena. Noncontrast T1WI in cardiac magnetic resonance imaging may be useful for the assessment of coronary plaque characterization in patients with coronary artery disease.

Entities:  

Mesh:

Year:  2009        PMID: 19520342     DOI: 10.1016/j.jcmg.2009.01.016

Source DB:  PubMed          Journal:  JACC Cardiovasc Imaging        ISSN: 1876-7591


  28 in total

Review 1.  Coronary Artery Plaque Imaging.

Authors:  Yibin Xie; Hang Jin; Mengsu Zeng; Debiao Li
Journal:  Curr Atheroscler Rep       Date:  2017-09       Impact factor: 5.113

2.  Two-dimensional visualization of cholesterol and cholesteryl esters within human coronary plaques by near-infrared fluorescence angioscopy.

Authors:  Yasumi Uchida; Yasuto Uchida; Yukou Sugiyama; Takanobu Tomaru; Seiji Kawai; Ryohei Kanamaru; Ei Shimoyama
Journal:  Clin Cardiol       Date:  2010-12       Impact factor: 2.882

3.  T1-weighted MRI for the detection of coronary artery plaque haemorrhage.

Authors:  May Lin Oei; Murat Ozgun; Harald Seifarth; Alexander Bunck; Roman Fischbach; Stefan Orwat; Walter Heindel; Rene Botnar; David Maintz
Journal:  Eur Radiol       Date:  2010-07-31       Impact factor: 5.315

4.  Accuracy of MRI to identify the coronary artery plaque: a comparative study with intravascular ultrasound.

Authors:  Yi He; Zhaoqi Zhang; Qinyi Dai; Yujie Zhou; Ya Yang; Wei Yu; Jing An; Lixin Jin; Renate Jerecic; Chun Yuan; Debiao Li
Journal:  J Magn Reson Imaging       Date:  2011-10-11       Impact factor: 4.813

Review 5.  Noninvasive imaging in coronary artery disease.

Authors:  Ran Heo; Ryo Nakazato; Dan Kalra; James K Min
Journal:  Semin Nucl Med       Date:  2014-09       Impact factor: 4.446

6.  Cardiovascular magnetic resonance imaging of myocardial infarction, viability, and cardiomyopathies.

Authors:  Amy M West; Christopher M Kramer
Journal:  Curr Probl Cardiol       Date:  2010-04       Impact factor: 5.200

7.  Differences of plaque characterization of high-intensity and non high-intensity plaques on non-contrast T1-weighted magnetic resonance imaging using angioscopy and optical coherence tomography.

Authors:  Akira Oshita; Hideo Kawakami; Shinsuke Kido; Toru Miyoshi; Hiroshi Matsuoka
Journal:  J Cardiol Cases       Date:  2017-05-05

8.  Atherosclerotic plaque imaging: the last frontier for cardiac magnetic resonance.

Authors:  Christopher M Kramer; Jagat Narula
Journal:  JACC Cardiovasc Imaging       Date:  2009-07

Review 9.  Prediction of cardiovascular outcomes by imaging coronary atherosclerosis.

Authors:  Faraz Pathan; Kazuaki Negishi
Journal:  Cardiovasc Diagn Ther       Date:  2016-08

Review 10.  Noninvasive imaging modalities to visualize atherosclerotic plaques.

Authors:  Daisuke Shishikura
Journal:  Cardiovasc Diagn Ther       Date:  2016-08
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.