Pitfalls in the determination of absolute dimensions using angiographic catheters as calibration devices in quantitative angiography.

D F Fortin1, L A Spero, J T Cusma, L Santoro, R Burgess, T M Bashore.   

Abstract

Using catheter outer diameter as a scaling device, quantitative coronary arteriography allows the precise and objective measurement of change in absolute dimensions of coronary arteries after mechanical or pharmacologic intervention. Because of variable density in the wall of the catheter, automated systems might vary in the determination of the outer catheter diameter. To examine this premise, catheters in a variety of French sizes from 6 manufacturers were injected with radiographic contrast and used as scaling devices for arterial phantoms of known geometric dimension. Radiographic diameters of the catheters were determined by applying the quantitative coronary arteriographic algorithm to the catheters using a calibration grid in the same field of view. The varying composition of the catheters resulted in differing x-ray attenuation and, subsequently, automated edge-detection algorithms varied widely in determining the actual catheter diameter to be used as a scaling factor. For instance, a Lucite "artery" with a minimal luminal diameter of 1.50 mm (image calibrated using the micrometer-determined outside diameter of a Baxter 8Fr guiding catheter) resulted in a quantitative angiographic diameter of 2.03 mm (overestimation by 35%). If the diameter of a similar size Shiley catheter was used to calibrate the image, a luminal diameter of 1.60 mm was determined: a difference of 0.43 mm based solely on differences in scaling catheter attenuation. These data suggest that a specific "fingerprint" for each catheter material and catheter French size exists, rendering generalizations about catheter size questionable. These observations are important for quantitative angiography where many brands and sizes of angiographic catheters are being used clinically.(ABSTRACT TRUNCATED AT 250 WORDS)

Mesh:

Year:  1991        PMID: 1951077     DOI: 10.1016/0002-9149(91)90190-v

Source DB:  PubMed          Journal:  Am J Cardiol        ISSN: 0002-9149            Impact factor:   2.778


  8 in total

1.  Comparison of self-expanding polyethylene terephthalate and metallic stents implanted in porcine iliac arteries.

Authors:  K Wilczek; I D Scheerder; K Wang; E Verbeken; J Piessens
Journal:  Cardiovasc Intervent Radiol       Date:  1996 May-Jun       Impact factor: 2.740

2.  Reproducibility of quantitative coronary analysis, Assessment of variability due to frame selection, different observers, and different cinefilmless laboratories.

Authors:  P A Sirnes; Y Myreng; P Mølstad; S Golf
Journal:  Int J Card Imaging       Date:  1996-09

3.  The impact of vessel orientation in space on densitometric measurements of cross sectional areas of coronary arteries.

Authors:  P A Doriot; P A Dorsaz; L Dorsaz; P Chatelain; W Rutishauser
Journal:  Int J Card Imaging       Date:  1996-12

4.  The impact of vessel and catheter position on the measurement accuracy in catheter-based quantitative coronary angiography.

Authors:  W Wunderlich; B Roehrig; F Fischer; H R Arntz; R Agrawal; A Morguet; H P Schultheiss; D Horstkotte
Journal:  Int J Card Imaging       Date:  1998-08

5.  Evaluation of fluorinated polymers as coronary stent coating.

Authors:  I Verweire; E Schacht; B P Qiang; K Wang; I De Scheerder
Journal:  J Mater Sci Mater Med       Date:  2000-04       Impact factor: 3.896

6.  Intra- and interobserver variability of a fast on-line quantitative coronary angiographic system.

Authors:  W Desmet; J L Willems; M Vrolix; J van Lierde; G Byttebier; J Piessens
Journal:  Int J Card Imaging       Date:  1993-12

7.  Coronary artery size as a predictor of Y-graft patency following coronary artery bypass surgery.

Authors:  Danang Himawan Limanto; Hyoung Woo Chang; Dong Jung Kim; Jun Sung Kim; Kay-Hyun Park; Cheong Lim
Journal:  Medicine (Baltimore)       Date:  2021-01-15       Impact factor: 1.817

8.  Improved method of magnification factor calculation for the angiographic measurement of neurovascular lesion dimensions.

Authors:  Zhou Wang; Stephen Rudin; Daniel R Bednarek; Laszlo Miskolczi
Journal:  J Appl Clin Med Phys       Date:  2002       Impact factor: 2.102

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.