Literature DB >> 19500321

Frequency of bacterial contamination of platelet concentrates before and after introduction of diversion method in Japan.

Masahiro Satake1, Takako Mitani, Shinji Oikawa, Hideto Nagumo, Sayoko Sugiura, Hidemi Tateyama, Syuji Awakihara, Yoshiro Mitsutomi, Masato Muraoka, Kenji Tadokoro.   

Abstract

BACKGROUND: Bacterial contamination of platelet concentrates (PCs) is the major infectious risk in transfusion medicine. To evaluate the necessity of implementing novel strategies for the reduction of bacterial contamination, it is necessary to establish a precise contamination frequency in PCs. STUDY DESIGN AND METHODS: The frequency of bacterial contamination in PCs issued by the Japanese Red Cross was determined using expired PCs before and after the implementation of the diversion method. The culture method was designed such that it yields the least possibility of false-negative results: platelet specimens were sampled after at least 4 days of storage and the inoculum volume was 10 mL for both aerobic and anaerobic bottle cultures.
RESULTS: Of the 21,786 PCs cultured, 36 (0.17%) were confirmed to be bacterially contaminated before the implementation of the diversion method. After its implementation, the number of contaminated PCs decreased to 11 of 21,783 (0.05%) with a reduction rate of 71% and the number of contaminations of clinical importance was 4 (0.018%) excluding PCs positive for Propionibacterium acnes. The frequency of contamination by bacteria presumed to originate from donors' blood did not decrease.
CONCLUSION: The effect of the diversion method on the frequency of bacterial contamination is robust. The low incidence of septic reactions after PC transfusion in Japan in spite of the contamination frequency being comparable to those in Western countries and the noninstitution of culture screening suggests the importance of a short shelf life (72 hr) for PCs introduced in Japan.

Entities:  

Mesh:

Year:  2009        PMID: 19500321     DOI: 10.1111/j.1537-2995.2009.02243.x

Source DB:  PubMed          Journal:  Transfusion        ISSN: 0041-1132            Impact factor:   3.157


  9 in total

1.  Transfusion-Transmitted Bacterial Infections - Haemovigilance Data of German Blood Establishments (1997-2010).

Authors:  Markus B Funk; Annette Lohmann; Serife Guenay; Olaf Henseler; Margarethe Heiden; Kay-Martin O Hanschmann; Brigitte Keller-Stanislawski
Journal:  Transfus Med Hemother       Date:  2011-07-08       Impact factor: 3.747

2.  Laboratory Evaluation of the Effectiveness of Pathogen Reduction Procedures for Bacteria.

Authors:  Thomas H Müller; Thomas Montag; Axel W Seltsam
Journal:  Transfus Med Hemother       Date:  2011-07-08       Impact factor: 3.747

3.  Evaluation of the Sensitivity and Specificity of Use of Glucose and pH for Bacterial Screening of Platelet Concentrates Compared to the Bact/Alert.

Authors:  Farhad Razjou; Hossein Timori Naghadeh; Shirin Ferdowsi; Abolfazl Dabirmoghadam
Journal:  Indian J Hematol Blood Transfus       Date:  2016-02-29       Impact factor: 0.900

4.  Long-term survival and quality of life after transfusion-associated pulmonary edema in critically ill medical patients.

Authors:  Guangxi Li; Marija Kojicic; Martin K Reriani; Evans R Fernández Pérez; Lokendra Thakur; Rahul Kashyap; Camille M Van Buskirk; Ognjen Gajic
Journal:  Chest       Date:  2009-10-16       Impact factor: 9.410

Review 5.  Microbiological Screening of Platelet Concentrates in Europe.

Authors:  Marcel Prax; Isabelle Bekeredjian-Ding; Oleg Krut
Journal:  Transfus Med Hemother       Date:  2019-03-20       Impact factor: 3.747

6.  Prevalence of Bacterial Contamination when using a Diversion Pouch during Blood Collection: A Single Center Study in Malaysia.

Authors:  Norlaili Jumaah; Sanmukh Ratilal Joshi; Doblin Sandai
Journal:  Malays J Med Sci       Date:  2014-05

7.  Bacterial Contamination and Susceptibility Pattern Among Blood and Blood Components Using Divergent and Non-Divergent Collection Methods at Armed Forces Comprehensive Specialized Hospital, Addis Ababa, Ethiopia.

Authors:  Wondwossen Tsegaye; Adane Bitew; Addisu Gize
Journal:  Infect Drug Resist       Date:  2022-04-08       Impact factor: 4.003

8.  Characteristics of False-Positive Alarms in the BacT/Alert 3D System.

Authors:  Misato Amano; Mami Matsumoto; Shigeru Sano; Mayumi Oyama; Hideto Nagumo; Naoko Watanabe-Okochi; Nelson H Tsuno; Kazunori Nakajima; Kazuo Muroi
Journal:  Microbiol Spectr       Date:  2022-04-25

9.  Evaluation of an ethidium monoazide-enhanced 16S rDNA real-time polymerase chain reaction assay for bacterial screening of platelet concentrates and comparison with automated culture.

Authors:  Jeremy A Garson; Poorvi Patel; Carl McDonald; Joanne Ball; Gillian Rosenberg; Kate I Tettmar; Susan R Brailsford; Tyrone Pitt; Richard S Tedder
Journal:  Transfusion       Date:  2013-05-23       Impact factor: 3.157

  9 in total