Literature DB >> 24236223

A Pico Projector Source for Confocal Fluorescence and Ophthalmic Imaging.

Matthew S Muller1.   

Abstract

A Pico digital light projector has been implemented as an integrated illumination source and spatial light modulator for confocal imaging. The target is illuminated with a series of rapidly projected lines or points to simulate scanning. Light returning from the target is imaged onto a 2D rolling shutter CMOS sensor. By controlling the spatio-temporal relationship between the rolling shutter and illumination pattern, light returning from the target is spatially filtered. Confocal retinal, fluorescence, and Fourier-domain optical coherence tomography implementations of this novel imaging technique are presented.

Entities:  

Keywords:  CMOS; DLP; Pico projector; biomedical imaging; confocal imaging; digital imaging; rolling shutter; spatial light modulator

Year:  2012        PMID: 24236223      PMCID: PMC3824265          DOI: 10.1117/12.909574

Source DB:  PubMed          Journal:  Proc SPIE Int Soc Opt Eng        ISSN: 0277-786X


  3 in total

1.  High sensitivity phase mapping with parallel Fourier domain optical coherence tomography at 512 000 A-scan/s.

Authors:  Branislav Grajciar; Yves Lehareinger; Adolf F Fercher; Rainer A Leitgeb
Journal:  Opt Express       Date:  2010-10-11       Impact factor: 3.894

2.  Performance of fourier domain vs. time domain optical coherence tomography.

Authors:  R Leitgeb; C Hitzenberger; Adolf Fercher
Journal:  Opt Express       Date:  2003-04-21       Impact factor: 3.894

3.  Parallel Fourier domain optical coherence tomography for in vivo measurement of the human eye.

Authors:  Branislav Grajciar; Michael Pircher; Adolf Fercher; Rainer Leitgeb
Journal:  Opt Express       Date:  2005-02-21       Impact factor: 3.894

  3 in total
  4 in total

1.  Non-mydriatic confocal retinal imaging using a digital light projector.

Authors:  Matthew S Muller; Jason J Green; Karthikeyan Baskaran; Allen W Ingling; Jeffrey L Clendenon; Thomas J Gast; Ann E Elsner
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2015-03-10

2.  Non-Mydriatic Confocal Retinal Imaging Using a Digital Light Projector.

Authors:  Matthew S Muller; Ann E Elsner; Glen Y Ozawa
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2013-03-26

3.  Confocal Retinal Imaging Using a Digital Light Projector with a Near Infrared VCSEL Source.

Authors:  Matthew S Muller; Ann E Elsner
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2018-02

4.  Line-scanning confocal microendoscope for nuclear morphometry imaging.

Authors:  Yubo Tang; Jennifer Carns; Rebecca R Richards-Kortum
Journal:  J Biomed Opt       Date:  2017-11       Impact factor: 3.170

  4 in total