Comparison of ring artifact correction methods for flat-detector CT.

Daniel Prell1, Yiannis Kyriakou, Willi A Kalender.   

Abstract

In flat-detector CT, imperfect or defect detector elements may cause concentric ring artifacts due to their continuous over- or underestimation of attenuation values, which often disturb image quality. Especially due to the demand for high-spatial resolution images and the necessary pixel read-out without arbitrary pixel-binning, ring artifacts become more pronounced and the reduction of these artifacts becomes a necessity. We here present a comparison of two dedicated ring artifact correction methods for flat-detector CT, on the basis of different median and mean filterings of the reconstructed image but each working in different geometric planes. While the first method works in Cartesian coordinates, the second method performs a transformation to polar coordinates. Both post-processing methods efficiently reduce ring artifacts in the reconstructed images and improve image quality. The transformation to polar coordinates turned out to be a necessary step for efficient ring artifact correction, since correction in Cartesian coordinates suffers from newly introduced artifacts as well as insufficient correction of artifacts close to the center of rotation.

Mesh:

Year:  2009        PMID: 19491452     DOI: 10.1088/0031-9155/54/12/018

Source DB:  PubMed          Journal:  Phys Med Biol        ISSN: 0031-9155            Impact factor:   3.609


  16 in total

1.  Angiographic CT after intravenous contrast agent application: A noninvasive follow-up tool after intracranial angioplasty and stenting.

Authors:  M-N Psychogios; P Schramm; J-H Buhk; A Xyda; K Gröschel; K Jung; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2010-07-15       Impact factor: 3.825

2.  Metal artifact reduction for clipping and coiling in interventional C-arm CT.

Authors:  D Prell; Y Kyriakou; T Struffert; A Dörfler; W A Kalender
Journal:  AJNR Am J Neuroradiol       Date:  2009-11-26       Impact factor: 3.825

Review 3.  Artefacts in CBCT: a review.

Authors:  R Schulze; U Heil; D Gross; D D Bruellmann; E Dranischnikow; U Schwanecke; E Schoemer
Journal:  Dentomaxillofac Radiol       Date:  2011-07       Impact factor: 2.419

4.  C-arm flat-panel CT arthrography of the shoulder: Radiation dose considerations and preliminary data on diagnostic performance.

Authors:  Roman Guggenberger; Erika J Ulbrich; Tobias J Dietrich; Rosemarie Scholz; Pascal Kaelin; Christoph Köhler; Thilo Elsässer; Thomas Le Corroller; Thomas Pfammatter; Hatem Alkadhi; Gustav Andreisek
Journal:  Eur Radiol       Date:  2016-05-24       Impact factor: 5.315

5.  Feasibility of flat panel angiographic CT after intravenous contrast agent application in the postoperative evaluation of patients with clipped aneurysms.

Authors:  M-N Psychogios; D Wachter; A Mohr; P Schramm; A-M Frölich; K Jung; V Rohde; M Knauth
Journal:  AJNR Am J Neuroradiol       Date:  2011-08-18       Impact factor: 3.825

6.  Longitudinal assessment of lung cancer progression in the mouse using in vivo micro-CT imaging.

Authors:  Eman Namati; Jacqueline Thiesse; Jessica C Sieren; Alan Ross; Eric A Hoffman; Geoffrey McLennan
Journal:  Med Phys       Date:  2010-09       Impact factor: 4.071

7.  Impacts of photon counting CT to maximum intensity projection (MIP) images of cerebral CT angiography: theoretical and experimental studies.

Authors:  Evan Cary Harvey; Mang Feng; Xu Ji; Ran Zhang; Yinsheng Li; Guang-Hong Chen; Ke Li
Journal:  Phys Med Biol       Date:  2019-09-19       Impact factor: 3.609

8.  A Convex Reconstruction Model for X-ray Tomographic Imaging with Uncertain Flat-fields.

Authors:  Hari Om Aggrawal; Martin S Andersen; Sean Rose; Emil Y Sidky
Journal:  IEEE Trans Comput Imaging       Date:  2017-07-04

9.  Material identification in x-ray microscopy and micro CT using multi-layer, multi-color scintillation detectors.

Authors:  Dimple Modgil; David S Rigie; Yuxin Wang; Xianghui Xiao; Phillip A Vargas; Patrick J La Rivière
Journal:  Phys Med Biol       Date:  2015-09-30       Impact factor: 3.609

10.  Comparison of ring artifact removal methods using flat panel detector based CT images.

Authors:  Emran M Abu Anas; Jae G Kim; Soo Y Lee; K Hasan
Journal:  Biomed Eng Online       Date:  2011-08-17       Impact factor: 2.819

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.