Literature DB >> 19465297

Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye.

Timo Eppig1, Katja Scholz, André Löffler, Arthur Messner, Achim Langenbucher.   

Abstract

PURPOSE: To determine the impact of decentration and tilt on the imaging quality of aspheric intraocular lens (IOL) designs in a schematic model eye.
SETTING: Institute of Medical Physics, University of Erlangen-Nuremberg, Erlangen, Germany.
METHOD: A model eye was used to calculate the impact of misalignment on the imaging quality of 6 IOL designs. The crystalline lens in the model eye was replaced with IOL designs with 22.0 diopters nominal refractive power, and the anterior chamber depth (ACD) was set to the estimated ACD value provided by the manufacturer. The retinal position was optimized for the best image quality. The IOLs were decentered up to +/-1.0 mm and tilted up to +/-5 degrees relative to the line of sight. At each position, the modulation transfer function was recorded with 3.0 mm and 4.5 mm pupil diameters. The results between the IOL designs and those of the phakic model eye were then compared.
RESULTS: Aberration-correcting IOLs were very sensitive to decentration and tilt. However, the impact of misalignment depended on IOL design. Aberration-free IOLs showed less sensitivity within a wide range of displacement but provided better results than the spherical IOL.
CONCLUSIONS: Overall, modern aspheric IOLs provided better imaging quality than conventional spherical IOL designs. Aberration-free IOLs were less sensitive to decentration and tilt than aberration-correcting IOLs but provided better image quality than spherical IOLs. Aberration-correcting IOLs have the potential to provide diffraction-limited imaging quality when perfectly aligned.

Mesh:

Year:  2009        PMID: 19465297     DOI: 10.1016/j.jcrs.2009.01.034

Source DB:  PubMed          Journal:  J Cataract Refract Surg        ISSN: 0886-3350            Impact factor:   3.351


  28 in total

1.  [Investigation of the theoretical image quality of aspheric intraocular lenses by decentration. Hoya AF-1 iMics1 und Zeiss ASPHINA(TM) (Invent ZO)].

Authors:  M Gillner; A Langenbucher; T Eppig
Journal:  Ophthalmologe       Date:  2012-03       Impact factor: 1.059

2.  Optical performance of toric intraocular lenses in the presence of decentration.

Authors:  Bin Zhang; Jin-Xue Ma; Dan-Yan Liu; Ying-Hua Du; Cong-Rong Guo; Yue-Xian Cui
Journal:  Int J Ophthalmol       Date:  2015-08-18       Impact factor: 1.779

3.  In vitro optical quality comparison between the Mini WELL Ready progressive multifocal and the TECNIS Symfony.

Authors:  Alberto Domínguez-Vicent; Jose Juan Esteve-Taboada; Antonio J Del Águila-Carrasco; Teresa Ferrer-Blasco; Robert Montés-Micó
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2015-12-16       Impact factor: 3.117

4.  Angle alpha as predictor for improving patient satisfaction with multifocal intraocular lenses?

Authors:  Andrzej Grzybowski; Timo Eppig
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2021-01-04       Impact factor: 3.117

5.  Temporal multiplexing with adaptive optics for simultaneous vision.

Authors:  Eleni Papadatou; Antonio J Del Águila-Carrasco; Iván Marín-Franch; Norberto López-Gil
Journal:  Biomed Opt Express       Date:  2016-09-15       Impact factor: 3.732

6.  Predicting crystalline lens fall caused by accommodation from changes in wavefront error.

Authors:  Lin He; Raymond A Applegate
Journal:  J Cataract Refract Surg       Date:  2011-07       Impact factor: 3.351

7.  Comparison of long-term decentration and tilt in two types of multifocal intraocular lenses with OPD-Scan III aberrometer.

Authors:  Wenwen He; Xiaodi Qiu; Shaohua Zhang; Yu Du; Yinglei Zhang; Yi Lu; Xiangjia Zhu
Journal:  Eye (Lond)       Date:  2018-03-09       Impact factor: 3.775

8.  Optical coherence tomography-based deep learning algorithm for quantification of the location of the intraocular lens.

Authors:  Chen Xin; Gui-Bin Bian; Haojie Zhang; Weipeng Liu; Zhe Dong
Journal:  Ann Transl Med       Date:  2020-07

Review 9.  Opto-Mechanical Eye Models, a Review on Human Vision Applications and Perspectives for Use in Industry.

Authors:  André Rino Amorim; Boris Bret; José M González-Méijome
Journal:  Sensors (Basel)       Date:  2022-10-10       Impact factor: 3.847

10.  Tilt and decentration of an intraocular lens implanted in the ciliary sulcus after capsular bag defect during cataract surgery.

Authors:  Thomas Sauer; Ulrich Mester
Journal:  Graefes Arch Clin Exp Ophthalmol       Date:  2012-09-02       Impact factor: 3.117

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.