Lin He1, Raymond A Applegate. 1. Visual Optics Institute, College of Optometry, University of Houston, Houston, Texas, USA. lhe.2011@alumni.opt.uh.edu
Abstract
PURPOSE: To illustrate and develop a method for estimating crystalline lens decentration as a function of accommodative response using changes in wavefront error and show the method and limitations using previously published data (2004) from 2 iridectomized monkey eyes so that clinicians understand how spherical aberration can induce coma, in particular in intraocular lens surgery. SETTINGS: College of Optometry, University of Houston, Houston, USA. DESIGN: Evaluation of diagnostic test or technology. METHODS: Lens decentration was estimated by displacing downward the wavefront error of the lens with respect to the limiting aperture (7.0 mm) and ocular first surface wavefront error for each accommodative response (0.00 to 11.00 diopters) until measured values of vertical coma matched previously published experimental data (2007). Lens decentration was also calculated using an approximation formula that only included spherical aberration and vertical coma. RESULTS: The change in calculated vertical coma was consistent with downward lens decentration. Calculated downward lens decentration peaked at approximately 0.48 mm of vertical decentration in the right eye and approximately 0.31 mm of decentration in the left eye using all Zernike modes through the 7th radial order. Calculated lens decentration using only coma and spherical aberration formulas was peaked at approximately 0.45 mm in the right eye and approximately 0.23 mm in the left eye. CONCLUSIONS: Lens fall as a function of accommodation was quantified noninvasively using changes in vertical coma driven principally by the accommodation-induced changes in spherical aberration. The newly developed method was valid for a large pupil only. FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.
PURPOSE: To illustrate and develop a method for estimating crystalline lens decentration as a function of accommodative response using changes in wavefront error and show the method and limitations using previously published data (2004) from 2 iridectomized monkey eyes so that clinicians understand how spherical aberration can induce coma, in particular in intraocular lens surgery. SETTINGS: College of Optometry, University of Houston, Houston, USA. DESIGN: Evaluation of diagnostic test or technology. METHODS: Lens decentration was estimated by displacing downward the wavefront error of the lens with respect to the limiting aperture (7.0 mm) and ocular first surface wavefront error for each accommodative response (0.00 to 11.00 diopters) until measured values of vertical coma matched previously published experimental data (2007). Lens decentration was also calculated using an approximation formula that only included spherical aberration and vertical coma. RESULTS: The change in calculated vertical coma was consistent with downward lens decentration. Calculated downward lens decentration peaked at approximately 0.48 mm of vertical decentration in the right eye and approximately 0.31 mm of decentration in the left eye using all Zernike modes through the 7th radial order. Calculated lens decentration using only coma and spherical aberration formulas was peaked at approximately 0.45 mm in the right eye and approximately 0.23 mm in the left eye. CONCLUSIONS:Lens fall as a function of accommodation was quantified noninvasively using changes in vertical coma driven principally by the accommodation-induced changes in spherical aberration. The newly developed method was valid for a large pupil only. FINANCIAL DISCLOSURE: Neither author has a financial or proprietary interest in any material or method mentioned.
Authors: S A Strenk; J L Semmlow; L M Strenk; P Munoz; J Gronlund-Jacob; J K DeMarco Journal: Invest Ophthalmol Vis Sci Date: 1999-05 Impact factor: 4.799
Authors: Raymond A Applegate; William J Donnelly; Jason D Marsack; Darren E Koenig; Konrad Pesudovs Journal: J Opt Soc Am A Opt Image Sci Vis Date: 2007-03 Impact factor: 2.129
Authors: Norberto López-Gil; Vicente Fernández-Sánchez; Richard Legras; Robert Montés-Micó; Francisco Lara; Jean Luc Nguyen-Khoa Journal: Invest Ophthalmol Vis Sci Date: 2008-04 Impact factor: 4.799