Literature DB >> 19438947

Early bone healing around different implant bulk designs and surgical techniques: A study in dogs.

Paulo G Coelho1, Marcelo Suzuki, Marcia V M Guimaraes, Charles Marin, Rodrigo Granato, Jose N Gil, Robert J Miller.   

Abstract

PURPOSE: To evaluate the bone healing response to different implant root shape designs in a dog model.
MATERIALS AND METHODS: Three by eight millimeter screw-type short-pitch (SP) and large-pitch (LP) implants (Intra-Lock International, Boca Raton, FL, USA), and 4.5 x 6 mm plateau (P) implants (Bicon LLC, Boston, MA, USA) were placed along the proximal tibia of six dogs for 2 and 4 weeks. The combination of implant design and final osteotomy drilling resulted in healing chambers for the LP and P implants. The implants were nondecalcified processed to plates of approximately 30-microm thickness and were evaluated by optical microscopy for healing patterns and bone-to-implant contact (BIC). One-way analysis of variance at 95% level of significance and Tukey's test were utilized for multiple comparisons among the groups' BIC.
RESULTS: Microscopy showed a approximately 150-microm region of newly deposited bone along the whole perimeter of SP implants, near the edge of the LP implant threads, and plateau tips for P implants. Rapid woven bone formation and filling was observed in regions where surgery and implant design resulted in healing chambers. No significant differences in BIC were observed (p > .75).
CONCLUSIONS: Different implant design/surgical protocol resulted in varied bone healing patterns. However, the BIC and bone morphology evolution between implant designs were comparable. Regardless of the combination between implant design and final osteotomy drilling, bone morphology evolution from 2 to 4 weeks was comparable.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19438947     DOI: 10.1111/j.1708-8208.2009.00153.x

Source DB:  PubMed          Journal:  Clin Implant Dent Relat Res        ISSN: 1523-0899            Impact factor:   3.932


  16 in total

1.  Slow drilling speeds for single-drill implant bed preparation. Experimental in vitro study.

Authors:  R A Delgado-Ruiz; E Velasco Ortega; G E Romanos; S Gerhke; I Newen; J L Calvo-Guirado
Journal:  Clin Oral Investig       Date:  2017-04-22       Impact factor: 3.573

2.  Effect of implant macrogeometry on peri-implant healing outcomes: a randomized clinical trial.

Authors:  Luiz Carlos do Carmo Filho; Fernanda Faot; Marina de Matos Madruga; Raissa Micaella Marcello-Machado; Dimorvan Bordin; Altair Antoninha Del Bel Cury
Journal:  Clin Oral Investig       Date:  2018-05-03       Impact factor: 3.573

3.  [Study on bone volume harvested from the implant sites with different methods].

Authors:  W T Li; P Li; M Z Piao; F Zhang; J DI
Journal:  Beijing Da Xue Xue Bao Yi Xue Ban       Date:  2020-02-18

4.  Effect of decreased implant healing time on bone (re)modeling adjacent to plateaued implants under functional loading in a dog model.

Authors:  Jing Dai; Ning Cheng; Richard J Miron; Bin Shi; Xiangrong Cheng; Yufeng Zhang
Journal:  Clin Oral Investig       Date:  2013-02-03       Impact factor: 3.573

5.  Survival rate of short, locking taper implants with a plateau design: a 5-year retrospective study.

Authors:  Kemal Özgür Demiralp; Nihat Akbulut; Sebnem Kursun; Didem Argun; Nilsun Bagis; Kaan Orhan
Journal:  Biomed Res Int       Date:  2015-04-16       Impact factor: 3.411

6.  Drilling dimension effects in early stages of osseointegration and implant stability in a canine model.

Authors:  Felipe-Eduardo Baires-Campos; Ryo Jimbo; Estevam-Augusto Bonfante; Maiolino-Thomaz Fonseca-Oliveira; Camila Moura; Darceny Zanetta-Barbosa; Paulo-Guilherme Coelho
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2015-07-01

7.  Physicochemical Characterization and In Vivo Evaluation of Amorphous and Partially Crystalline Calcium Phosphate Coatings Fabricated on Ti-6Al-4V Implants by the Plasma Spray Method.

Authors:  Estevam A Bonfante; Lukasz Witek; Nick Tovar; Marcelo Suzuki; Charles Marin; Rodrigo Granato; Paulo G Coelho
Journal:  Int J Biomater       Date:  2012-08-27

8.  Plasma treatment maintains surface energy of the implant surface and enhances osseointegration.

Authors:  Fernando P S Guastaldi; Daniel Yoo; Charles Marin; Ryo Jimbo; Nick Tovar; Darceny Zanetta-Barbosa; Paulo G Coelho
Journal:  Int J Biomater       Date:  2013-01-10

9.  Surface characterization and in vivo evaluation of laser sintered and machined implants followed by resorbable-blasting media process: A study in sheep.

Authors:  Michelle Bowers; Daniel Yoo; Charles Marin; Luiz Gil; Nour Shabaka; Matt Goldstein; Malvin Janal; Nick Tovar; Ronaldo Hirata; Estevam Bonfante; Paulo Coelho
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2016-03-01

10.  Five Years Follow-up of Short Implants Placed in Atrophic Maxilla with Simultaneous Sinus Floor Transcrestal Elevation.

Authors:  Stefano Carelli; Alfredo Passaretti; Giulia Petroni; Alessio Zanza; Luca Testarelli; Andrea Cicconetti
Journal:  Acta Stomatol Croat       Date:  2021-06
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.