Literature DB >> 32071471

[Study on bone volume harvested from the implant sites with different methods].

W T Li1, P Li1, M Z Piao1, F Zhang1, J DI1.   

Abstract

OBJECTIVE: To compare the volume of autogenous bone particles harvested utilizing different techniques and various implant systems during implant surgery, and to determine the advantageous method to collect autogenous bone particles.
METHODS: Homogeneous epoxy resin simulated jaw bone model was enrolled. Bicon, Bego implant systems and Straumann tissue level implant systems were utilized. The two techniques were investigated. One method was low-speed drilling (50 r/min) without water irrigating, and the other one was drilling with cold water irrigating to the ideal depth, then closing the water and drilling out with low speed (50 r/min). The bone particles in the drill groove and implant beds were collected. The volumes of the bone harvested were compared between the different techniques and also among the three implant systems, then they were compared with the volume of the bone harvested by the special bone drill. The sample size of each sub-group was 10. The bone particles were weighed by electronic balance after drying.
RESULTS: The harvested bone volume between the latch reamers and hand reamers of Bicon system with the first method was not significantly different. When the same size implant bed was prepared, the volume of the bone particles produced during the implant surgery with low-speed drill without water was significantly higher than that with the other method no matter Bicon [3.5 mm×10 mm hole for example (28.42±6.04) mg vs. (6.30±2.51) mg, P<0.001] or Bego system [2.8 mm×10 mm hole for example (28.95±5.39) mg vs. (4.61±3.39) mg, P<0.001] was used, and the ratio of bone volume between the first method and the second one was approximately 3.3 to 7.0 times. When using the second method to prepare the similar size implant bed, the bone volume was not significant different among Bicon, Bego and Straumann implant systems [Bicon (9.90±3.42) mg, Bego (8.70±4.09) mg, and Straumann (10.56±5.66) mg, P=0.69]. When preparing a 5 mm-diameter-10 mm-length hole with Bicon implant system and a 4.7 mm-diameter-10 mm-length with Bego implant system, the bone quantity harvested from each group was less than that harvested by special bone drill from Neo Biotech [Bicon (82.54±12.26) mg, Bego (85.07±12.64) mg vs. Neo Biotech (96.78±13.19) mg, P<0.05].
CONCLUSION: More autogenous bone can be harvested from implant beds by preparing with low-speed rolling without water than the method with water irrigation. When utilizing the same preparing method, the implant system has no impact on the volume of the bone harvested.

Entities:  

Mesh:

Year:  2020        PMID: 32071471      PMCID: PMC7439076     

Source DB:  PubMed          Journal:  Beijing Da Xue Xue Bao Yi Xue Ban        ISSN: 1671-167X


  11 in total

1.  A lateral approach for sinus elevation using PRGF technology.

Authors:  Eduardo Anitua; Roberto Prado; Gorka Orive
Journal:  Clin Implant Dent Relat Res       Date:  2009-05-12       Impact factor: 3.932

2.  Autogenous bone harvest for implant reconstruction.

Authors:  Avichai Stern; Golaleh Barzani
Journal:  Dent Clin North Am       Date:  2015-01-02

3.  Osteogenic potential of three different autogenous bone particles harvested during implant surgery.

Authors:  C Liang; X Lin; S-L Wang; L-H Guo; X-Y Wang; J Li
Journal:  Oral Dis       Date:  2017-07-21       Impact factor: 3.511

4.  Clinical and radiographic intra-subject comparison of implants placed with or without guided bone regeneration: 15-year results.

Authors:  Goran I Benic; Mira Bernasconi; Ronald E Jung; Christoph H F Hämmerle
Journal:  J Clin Periodontol       Date:  2017-02-01       Impact factor: 8.728

5.  Alveolar bone marrow as a cell source for regenerative medicine: differences between alveolar and iliac bone marrow stromal cells.

Authors:  Takehiro Matsubara; Ketut Suardita; Masakazu Ishii; Masaru Sugiyama; Akira Igarashi; Ryo Oda; Masahiro Nishimura; Masahiro Saito; Keigo Nakagawa; Katsuyuki Yamanaka; Kazuko Miyazaki; Masakazu Shimizu; Ujjal K Bhawal; Koichiro Tsuji; Kozo Nakamura; Yukio Kato
Journal:  J Bone Miner Res       Date:  2004-11-29       Impact factor: 6.741

6.  Early bone healing around different implant bulk designs and surgical techniques: A study in dogs.

Authors:  Paulo G Coelho; Marcelo Suzuki; Marcia V M Guimaraes; Charles Marin; Rodrigo Granato; Jose N Gil; Robert J Miller
Journal:  Clin Implant Dent Relat Res       Date:  2009-05-07       Impact factor: 3.932

7.  Horizontal Ridge Augmentation using GBR with a Native Collagen Membrane and 1:1 Ratio of Particulated Xenograft and Autologous Bone: A 1-Year Prospective Clinical Study.

Authors:  Silvio Mario Meloni; Sascha A Jovanovic; Istvan Urban; Luigi Canullo; Milena Pisano; Marco Tallarico
Journal:  Clin Implant Dent Relat Res       Date:  2016-06-09       Impact factor: 3.932

8.  Satisfaction and psychosocial aspects of patients with an extremely resorbed mandible treated with implant-retained overdentures. A prospective, comparative study.

Authors:  Kees Stellingsma; Jelte Bouma; Boudewijn Stegenga; Henny J A Meijer; Gerry M Raghoebar
Journal:  Clin Oral Implants Res       Date:  2003-04       Impact factor: 5.977

9.  Temperature change in pig rib bone during implant site preparation by low-speed drilling.

Authors:  Sun-Jong Kim; Jaeyoung Yoo; Young-Soo Kim; Sang-Wan Shin
Journal:  J Appl Oral Sci       Date:  2010 Sep-Oct       Impact factor: 2.698

10.  The effect of low-speed drilling without irrigation on heat generation: an experimental study.

Authors:  Ji-Hyeon Oh; Yiqin Fang; Seung-Mi Jeong; Byung-Ho Choi
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2016-02-15
View more
  1 in total

Review 1.  Low-speed drilling without irrigation versus conventional drilling for dental implant osteotomy preparation: a systematic review.

Authors:  Juan Carlos Bernabeu-Mira; David Soto-Peñaloza; Miguel Peñarrocha-Diago; Fabio Camacho-Alonso; Rebeca Rivas-Ballester; David Peñarrocha-Oltra
Journal:  Clin Oral Investig       Date:  2021-04-24       Impact factor: 3.573

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.