Literature DB >> 19417876

A comparative in vitro study on the retention and stability of implant-supported overdentures.

Walid Sadig1.   

Abstract

OBJECTIVES: Implant-supported overdentures have become the treatment of choice in restoring complete edentulism, but the number of implants required and type of connectors to assure retention and stability are still controversial. The aim of this study was to evaluate the effect of connector type and implant number and location on the retention and stability of implant-supported overdentures by measuring retentive forces during vertical and 2 types of rotational dislodgment. METHOD AND MATERIALS: Two model designs were selected based on the number and location of the inserted implants: In a first setup, 2 implants were placed in the canine regions; in a second setup, 2 implants were placed in the canine regions and 2 in the premolar regions. Three types of connector were used in each model: magnets, balls, and locators; 10 resin bases were fabricated and 3 hooks fixed at tripodal locations for chain testing. Vertical dislodging forces and 2 aspects (oblique and posterior rotational dislodging forces) of stability were tested.
RESULTS: Two-way analysis of variance showed significant differences in retention among the 3 connectors in the 2 models, with the lowest values obtained with the magnet group (mean [SD]: 2.15 N [0.09]) and highest values with the locator group (31.30 N [0.12]). Posterior rotational dislodging forces showed higher values than vertical or lateral forces in both models; 4-implant models required higher dislodging forces than did 2-implant models.
CONCLUSION: Locator connectors provide significantly higher retention and stability of implant-supported overdentures, followed by ball connectors and then magnets. The 2-implant design offers less retention and stability than the 4-implant model. Number of implants and type of connector significantly affected retention and stability of implant-supported overdentures.

Entities:  

Mesh:

Year:  2009        PMID: 19417876

Source DB:  PubMed          Journal:  Quintessence Int        ISSN: 0033-6572            Impact factor:   1.677


  17 in total

1.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

2.  Overdenture locator attachments for atrophic mandible.

Authors:  Neerja Mahajan; Rahul K Thakkur
Journal:  Contemp Clin Dent       Date:  2013-10

3.  Retentive characteristics of a vinylpolysiloxane overdenture attachment system.

Authors:  Ramona Schweyen; Florian Beuer; Christian Arnold; Jeremias Hey
Journal:  Clin Oral Investig       Date:  2014-08-22       Impact factor: 3.573

4.  Locator® versus ceramic/electroplated double-crown attachments: a prospective study on the intraindividual comparison of implant-supported mandibular prostheses.

Authors:  Silvia Brandt; Jan Brandt; Ali-Reza Ketabi; Hans-Christoph Lauer; Anna Kunzmann
Journal:  Clin Oral Investig       Date:  2018-05-19       Impact factor: 3.573

Review 5.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

Review 6.  Rehabilitation with implant-supported overdentures in total edentulous patients: A review.

Authors:  Juan F Martínez-Lage-Azorín; Gustavo Segura-Andrés; Joan Faus-López; Rubén Agustín-Panadero
Journal:  J Clin Exp Dent       Date:  2013-12-01

7.  In vitro retention force measurement for three different attachment systems for implant-retained overdenture.

Authors:  Kareem Mohammed Reda; Ibrahim Ramadan El-Torky; Mohamed Nabeel El-Gendy
Journal:  J Indian Prosthodont Soc       Date:  2016 Oct-Dec

8.  Influence of Number of Implants and Attachment Type on Stress Distribution in Mandibular Implant-Retained Overdentures: Finite Element Analysis.

Authors:  Mohamed I El-Anwar; Eman A El-Taftazany; Hamdy A Hamed; Mohamed A Abd ElHay
Journal:  Open Access Maced J Med Sci       Date:  2017-03-22

9.  Masticatory efficiency and oral health-related quality of life with implant-retained mandibular overdentures.

Authors:  Xu Sun; Jun-Jiang Zhai; Jian Liao; Min-Hua Teng; Ai Tian; Xing Liang
Journal:  Saudi Med J       Date:  2014-10       Impact factor: 1.484

10.  Strains around distally inclined implants retaining mandibular overdentures with Locator attachments: an in vitro study.

Authors:  Moustafa Abdou Elsyad; Fathi Abo Setta; Ahmed Samir Khirallah
Journal:  J Adv Prosthodont       Date:  2016-04-21       Impact factor: 1.904

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.