Literature DB >> 24403798

Overdenture locator attachments for atrophic mandible.

Neerja Mahajan1, Rahul K Thakkur2.   

Abstract

Implant-supported overdentures provide a good opportunity for dentists to improve oral health and quality-of-life of patients. Atrophic mandible poses a significant challenge to successful oral rehabilitation with dental implants. In this article, the fabrication of lower overdenture by two narrow platform implants is described with dual retentive, resilient, self-locating locator attachment system. The locator attachment system has the lowest profile in comparison with the ball and bar attachments and is versatile up to 40° of divergence between two implants. By using locators as attachments, we can meet functional, economic and social expectation of patients with ease and satisfaction.

Entities:  

Keywords:  Implants; locators attachments; overdentures

Year:  2013        PMID: 24403798      PMCID: PMC3883333          DOI: 10.4103/0976-237X.123060

Source DB:  PubMed          Journal:  Contemp Clin Dent        ISSN: 0976-2361


  10 in total

1.  Long-term neuromuscular status in overdenture and complete denture patients with severe mandibular atrophy.

Authors:  Caroline Spitzl; Peter Pröschel; Manfred Wichmann; Siegfried Heckmann
Journal:  Int J Oral Maxillofac Implants       Date:  2012 Jan-Feb       Impact factor: 2.804

2.  Effective denture stabilization in an atrophic mandible.

Authors:  Brian J Jackson
Journal:  Dent Today       Date:  2012-02

3.  Prosthodontic maintenance requirements of implant-retained overdentures using the locator attachment system.

Authors:  Joe Vere; Derek Hall; Raj Patel; Phillip Wragg
Journal:  Int J Prosthodont       Date:  2012 Jul-Aug       Impact factor: 1.681

4.  A comparative in vitro study on the retention and stability of implant-supported overdentures.

Authors:  Walid Sadig
Journal:  Quintessence Int       Date:  2009-04       Impact factor: 1.677

Review 5.  Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature.

Authors:  L Sennerby; J Roos
Journal:  Int J Prosthodont       Date:  1998 Sep-Oct       Impact factor: 1.681

6.  Complications associated with the ball, bar and Locator attachments for implant-supported overdentures.

Authors:  Sirmahan Cakarer; Taylan Can; Mehmet Yaltirik; Cengizhan Keskin
Journal:  Med Oral Patol Oral Cir Bucal       Date:  2011-11-01

7.  Two implant retained overdentures--a review of the literature supporting the McGill and York consensus statements.

Authors:  J M Thomason; S A M Kelly; A Bendkowski; J S Ellis
Journal:  J Dent       Date:  2011-09-03       Impact factor: 4.379

8.  Single unit attachments improve peri-implant soft tissue conditions in mandibular overdentures supported by four implants.

Authors:  Luca Cordaro; Vincenzo Mirisola di Torresanto; Nikola Petricevic; Primitivo Roig Jornet; Ferruccio Torsello
Journal:  Clin Oral Implants Res       Date:  2012-02-10       Impact factor: 5.977

9.  The extremely resorbed mandible: a comparative prospective study of 2-year results with 3 treatment strategies.

Authors:  Kees Stellingsma; Gerry M Raghoebar; Henny J A Meijer; Boudewijn Stegenga
Journal:  Int J Oral Maxillofac Implants       Date:  2004 Jul-Aug       Impact factor: 2.804

10.  Two versus three narrow-diameter implants with locator attachments supporting mandibular overdentures: a two-year prospective study.

Authors:  Ali M El-Sheikh; Omar F Shihabuddin; Sahar M F Ghoraba
Journal:  Int J Dent       Date:  2012-06-18
  10 in total
  2 in total

1.  Retention and patient satisfaction with bar-clip, ball and socket and kerator attachments in mandibular implant overdenture treatment: An in vivo study.

Authors:  Nitish Varshney; Sumit Aggarwal; Shalabh Kumar; S P Singh
Journal:  J Indian Prosthodont Soc       Date:  2019 Jan-Mar

Review 2.  A systematic review and meta-analysis of the attachments used in implant-supported overdentures.

Authors:  Sachin Haribhau Chaware; Smruti Tushar Thakkar
Journal:  J Indian Prosthodont Soc       Date:  2020-07-17
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.