Literature DB >> 1941145

An evaluation of forearm bone mineral measurement with dual-energy X-ray absorptiometry.

G Larcos1, H W Wahner.   

Abstract

Dual-energy x-ray absorptiometry (DEXA) has been reported to be a valuable means of bone mineral measurement of the lumbar spine and hip. In order to determine whether DEXA could be as useful for bone mineral analysis of the forearm, we compared its accuracy, precision and measurement performance to single-photon absorptiometry (SPA). There was high correlation between these techniques for integral bone mineral density in standard aluminum tubes (r = 0.99) and 30 adult volunteers or patients with osteoporosis (r = 0.95). The mean short-term precision of DEXA was 0.9% in vitro and about 1.5% in vivo. DEXA produced excellent bone images which enhance long-term in vivo precision. The measurement performance of both instruments was largely unaffected by localized fat deposits or increases in forearm thickness or proportion of fat subcutaneously. We conclude that DEXA is a clinically useful alternative to SPA for forearm bone mineral assessment.

Entities:  

Mesh:

Year:  1991        PMID: 1941145

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  7 in total

1.  A study of bone densitometry in patients with complex regional pain syndrome after stroke.

Authors:  V Kumar; J Kalita; R B Gujral; V P Sharma; U K Misra
Journal:  Postgrad Med J       Date:  2001-08       Impact factor: 2.401

2.  Geometric variables from DXA of the radius predict forearm fracture load in vitro.

Authors:  E R Myers; A T Hecker; D S Rooks; J A Hipp; W C Hayes
Journal:  Calcif Tissue Int       Date:  1993-03       Impact factor: 4.333

3.  Metacarpal bone mass in normal and osteoporotic Japanese women using computed X-ray densitometry.

Authors:  C Matsumoto; K Kushida; K Yamazaki; K Imose; T Inoue
Journal:  Calcif Tissue Int       Date:  1994-11       Impact factor: 4.333

4.  Increased bone mineral content of preterm infants fed with a nutrient enriched formula after discharge from hospital.

Authors:  N J Bishop; F J King; A Lucas
Journal:  Arch Dis Child       Date:  1993-05       Impact factor: 3.791

5.  Accuracy and precision study in vitro for peripheral quantitative computed tomography.

Authors:  M Takada; K Engelke; S Hagiwara; S Grampp; H K Genant
Journal:  Osteoporos Int       Date:  1996       Impact factor: 4.507

6.  Densitometry of the radius using single and dual energy absorptiometry.

Authors:  K G Faulkner; M R McClung; M S Schmeer; L A Roberts; K W Gaither
Journal:  Calcif Tissue Int       Date:  1994-03       Impact factor: 4.333

7.  Peripheral bone density in patients with rheumatoid arthritis.

Authors:  Helmut Franck; Jurgen Gottwalt
Journal:  Clin Rheumatol       Date:  2009-06-16       Impact factor: 2.980

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.