Literature DB >> 28866490

Hadamard-Encoded Multipulses for Contrast-Enhanced Ultrasound Imaging.

Ping Gong, Pengfei Song, Shigao Chen.   

Abstract

The development of contrast-enhanced ultrasound (CEUS) imaging offers great opportunities for new ultrasound clinical applications such as myocardial perfusion imaging and abdominal lesion characterization. In CEUS imaging, the contrast agents (i.e., microbubbles) are utilized to improve the contrast between blood and tissue based on their high nonlinearity under low ultrasound pressure. In this paper, we propose a new CEUS pulse sequence by combining Hadamard-encoded multipulses (HEM) with fundamental frequency bandpass filter (i.e., filter centered on transmit frequency). HEM consecutively emits multipulses encoded by a second-order Hadamard matrix in each of the two transmission events (i.e., pulse-echo events), as opposed to conventional CEUS methods which emit individual pulses in two separate transmission events (i.e., pulse inversion (PI), amplitude modulation (AM), and PIAM). In HEM imaging, the microbubble responses can be improved by the longer transmit pulse, and the tissue harmonics can be suppressed by the fundamental frequency filter, leading to significantly improved contrast-to-tissue ratio (CTR) and signal-to-noise ratio (SNR). In addition, the fast polarity change between consecutive coded pulse emissions excites strong nonlinear microbubble echoes, further enhancing the CEUS image quality. The spatial resolution of HEM image is compromised as compared to other microbubble imaging methods due to the longer transmit pulses and the lower imaging frequency (i.e., fundamental frequency). However, the resolution loss was shown to be negligible and could be offset by the significantly enhanced CTR, SNR, and penetration depth. These properties of HEM can potentially facilitate robust CEUS imaging for many clinical applications, especially for deep abdominal organs and heart.

Entities:  

Mesh:

Substances:

Year:  2017        PMID: 28866490      PMCID: PMC5664168          DOI: 10.1109/TUFFC.2017.2747219

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  18 in total

1.  Assessment of resting perfusion with myocardial contrast echocardiography: theoretical and practical considerations.

Authors:  J R Lindner; F S Villanueva; J M Dent; K Wei; J Sklenar; S Kaul
Journal:  Am Heart J       Date:  2000-02       Impact factor: 4.749

2.  Pulse inversion imaging of liver blood flow: improved method for characterizing focal masses with microbubble contrast.

Authors:  P N Burns; S R Wilson; D H Simpson
Journal:  Invest Radiol       Date:  2000-01       Impact factor: 6.016

3.  Techniques for perfusion imaging with microbubble contrast agents.

Authors:  D H Simpson; P N Burns; M A Averkiou
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2001-11       Impact factor: 2.725

4.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography.

Authors:  Gabriel Montaldo; Mickaël Tanter; Jérémy Bercoff; Nicolas Benech; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

5.  Ultrafast imaging of ultrasound contrast agents.

Authors:  Olivier Couture; Souad Bannouf; Gabriel Montaldo; Jean-François Aubry; Mathias Fink; Mickael Tanter
Journal:  Ultrasound Med Biol       Date:  2009-08-20       Impact factor: 2.998

6.  Second harmonic inversion for ultrasound contrast harmonic imaging.

Authors:  Mirza Pasovic; Mike Danilouchkine; Telli Faez; Paul L M J van Neer; Christian Cachard; Antonius F W van der Steen; Olivier Basset; Nico de Jong
Journal:  Phys Med Biol       Date:  2011-05-04       Impact factor: 3.609

7.  Ultrasound contrast plane wave imaging.

Authors:  Olivier Couture; Mathias Fink; Mickael Tanter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-12       Impact factor: 2.725

8.  Microbubble contrast agent detection using binary coded pulses.

Authors:  Robert J Eckersley; Meng-Xing Tang; Kevin Chetty; Joseph V Hajnal
Journal:  Ultrasound Med Biol       Date:  2007-07-16       Impact factor: 2.998

9.  Characterization and evaluation of tissue-mimicking gelatin phantoms for use with MRgFUS.

Authors:  Alexis I Farrer; Henrik Odéen; Joshua de Bever; Brittany Coats; Dennis L Parker; Allison Payne; Douglas A Christensen
Journal:  J Ther Ultrasound       Date:  2015-06-16

10.  Optimising phase and amplitude modulation schemes for imaging microbubble contrast agents at low acoustic power.

Authors:  Robert J Eckersley; Chien Ting Chin; Peter N Burns
Journal:  Ultrasound Med Biol       Date:  2005-02       Impact factor: 2.998

View more
  3 in total

1.  On Combination of Hadamard-Encoded Multipulses and Multiplane Wave Transmission in Contrast-Enhanced Ultrasound Imaging.

Authors:  Ping Gong; Pengfei Song; Chengwu Huang; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2018-07-11       Impact factor: 2.725

2.  Machine learning algorithm of ultrasound-mediated intestinal function recovery and nursing efficacy analysis of lower gastrointestinal malignant tumor after surgery.

Authors:  Lei Ma; Hao Zhang
Journal:  Pak J Med Sci       Date:  2021       Impact factor: 1.088

3.  Comparative study of core needle biopsy and fine needle aspiration in the treatment of metastatic lymph nodes guided by contrast-enhanced ultrasound.

Authors:  Wei-Na Mu; Jian-Heng Li; Ying Liu; Hui-Qing Liang; Xin Liu
Journal:  Pak J Med Sci       Date:  2022 Jul-Aug       Impact factor: 2.340

  3 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.