Literature DB >> 29727284

Probe Oscillation Shear Wave Elastography: Initial In Vivo Results in Liver.

Daniel C Mellema, Pengfei Song, Randall R Kinnick, Joshua D Trzasko, Matthew W Urban, James F Greenleaf, Armando Manduca, Shigao Chen.   

Abstract

Shear wave elastography methods are able to accurately measure tissue stiffness, allowing these techniques to monitor the progression of hepatic fibrosis. While many methods rely on acoustic radiation force to generate shear waves for 2-D imaging, probe oscillation shear wave elastography (PROSE) provides an alternative approach by generating shear waves through continuous vibration of the ultrasound probe while simultaneously detecting the resulting motion. The generated shear wave field in in vivo liver is complicated, and the amplitude and quality of these shear waves can be influenced by the placement of the vibrating probe. To address these challenges, a real-time shear wave visualization tool was implemented to provide instantaneous visual feedback to optimize probe placement. Even with the real-time display, it was not possible to fully suppress residual motion with established filtering methods. To solve this problem, the shear wave signal in each frame was decoupled from motion and other sources through the use of a parameter-free empirical mode decomposition before calculating shear wave speeds. This method was evaluated in a phantom as well as in in vivo livers from five volunteers. PROSE results in the phantom as well as in vivo liver correlated well with independent measurements using the commercial General Electric Logiq E9 scanner.

Entities:  

Mesh:

Year:  2018        PMID: 29727284      PMCID: PMC5937941          DOI: 10.1109/TMI.2017.2780855

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  23 in total

1.  Shear wave elasticity imaging: a new ultrasonic technology of medical diagnostics.

Authors:  A P Sarvazyan; O V Rudenko; S D Swanson; J B Fowlkes; S Y Emelianov
Journal:  Ultrasound Med Biol       Date:  1998-11       Impact factor: 2.998

2.  Shear-wave generation using acoustic radiation force: in vivo and ex vivo results.

Authors:  Kathryn Nightingale; Stephen McAleavey; Gregg Trahey
Journal:  Ultrasound Med Biol       Date:  2003-12       Impact factor: 2.998

3.  Multidimensional directional filter banks and surfacelets.

Authors:  Yue M Lu; Minh N Do
Journal:  IEEE Trans Image Process       Date:  2007-04       Impact factor: 10.856

4.  Ultrasonic imaging of internal vibration of soft tissue under forced vibration.

Authors:  Y Yamakoshi; J Sato; T Sato
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1990       Impact factor: 2.725

5.  Coherent plane-wave compounding for very high frame rate ultrasonography and transient elastography.

Authors:  Gabriel Montaldo; Mickaël Tanter; Jérémy Bercoff; Nicolas Benech; Mathias Fink
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-03       Impact factor: 2.725

6.  External vibration multi-directional ultrasound shearwave elastography (EVMUSE): application in liver fibrosis staging.

Authors:  Heng Zhao; Pengfei Song; Duane D Meixner; Randall R Kinnick; Matthew R Callstrom; William Sanchez; Matthew W Urban; Armando Manduca; James F Greenleaf; Shigao Chen
Journal:  IEEE Trans Med Imaging       Date:  2014-07-09       Impact factor: 10.048

7.  Magnetic resonance elastography: non-invasive mapping of tissue elasticity.

Authors:  A Manduca; T E Oliphant; M A Dresner; J L Mahowald; S A Kruse; E Amromin; J P Felmlee; J F Greenleaf; R L Ehman
Journal:  Med Image Anal       Date:  2001-12       Impact factor: 8.545

8.  Elastography Assessment of Liver Fibrosis: Society of Radiologists in Ultrasound Consensus Conference Statement.

Authors:  Richard G Barr; Giovanna Ferraioli; Mark L Palmeri; Zachary D Goodman; Guadalupe Garcia-Tsao; Jonathan Rubin; Brian Garra; Robert P Myers; Stephanie R Wilson; Deborah Rubens; Deborah Levine
Journal:  Radiology       Date:  2015-06-16       Impact factor: 11.105

9.  Two-dimensional shear-wave elastography on conventional ultrasound scanners with time-aligned sequential tracking (TAST) and comb-push ultrasound shear elastography (CUSE).

Authors:  Pengfei Song; Michael Macdonald; Russell Behler; Justin Lanning; Michael Wang; Matthew Urban; Armando Manduca; Heng Zhao; Matthew Callstrom; Azra Alizad; James Greenleaf; Shigao Chen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2015-02       Impact factor: 2.725

10.  Transient elastography: a new noninvasive method for assessment of hepatic fibrosis.

Authors:  Laurent Sandrin; Bertrand Fourquet; Jean-Michel Hasquenoph; Sylvain Yon; Céline Fournier; Frédéric Mal; Christos Christidis; Marianne Ziol; Bruno Poulet; Farad Kazemi; Michel Beaugrand; Robert Palau
Journal:  Ultrasound Med Biol       Date:  2003-12       Impact factor: 2.998

View more
  2 in total

1.  Three-dimensional shear wave elastography on conventional ultrasound scanners with external vibration.

Authors:  Chengwu Huang; Pengfei Song; Daniel C Mellema; Ping Gong; U-Wai Lok; Shanshan Tang; Wenwu Ling; Duane D Meixner; Matthew W Urban; Armando Manduca; James F Greenleaf; Shigao Chen
Journal:  Phys Med Biol       Date:  2020-11-05       Impact factor: 3.609

2.  Quantitative Shear Wave Speed Assessment for Muscles With the Diagnosis of Taut Bands and/or Myofascial Trigger Points Using Probe Oscillation Shear Wave Elastography: A Pilot Study.

Authors:  U-Wai Lok; Chengwu Huang; Chenyun Zhou; Lulu Yang; Wenwu Ling; Shanshan Tang; Ping Gong; Timothy J Madson; Mark A Jensen; Ralph E Gay; Shigao Chen
Journal:  J Ultrasound Med       Date:  2021-06-04       Impact factor: 2.754

  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.