Literature DB >> 16369157

Investigation of C-arm cone-beam CT-guided surgery of the frontal recess.

M A Rafferty1, J H Siewerdsen, Y Chan, D J Moseley, M J Daly, D A Jaffray, J C Irish.   

Abstract

OBJECTIVE/HYPOTHESIS: A cone-beam CT (CBCT) imaging system based on a mobile C-arm (Siemens PowerMobil) incorporating a high-performance flat-panel detector (Varian PaxScan) has been developed in our laboratory. We hypothesize that intraoperative C-arm CBCT provides image quality and guidance performance sufficient to assist surgical approach to the frontal recess. STUDY
DESIGN: A preclinical prospective study was conducted using six cadaver heads to assess the performance characteristics and the potential clinical utility of this imaging system.
METHODS: The mobile C-arm was employed for intraoperative CBCT guidance of the endoscopic approach to twelve frontal recesses.
RESULTS: The imaging system is capable of sub-mm 3D spatial resolution with bone and soft-tissue visibility and a field of view sufficient for guidance of head and neck surgery. The system can generate intraoperative, volumetric CT images rapidly with an acceptably low radiation exposure to the patient and with image quality sufficient for most surgical tasks. Moreover, the system is portable and compatible with the surgical setup, providing excellent access to the patient. Finally, the accuracy of the system is not bound to a registration process.
CONCLUSIONS: The ability to create updated images as surgery progresses introduces the concept of 'near-real-time' CT guidance for head and neck surgery. We found that the use of CBCT increased surgical confidence in accessing the frontal recess, resolved ambiguities with anatomical variations, and provided valuable teaching information to surgeons in training in both preoperative planning and correlation between tri-planar CT scans and intraoperative endoscopic findings.

Entities:  

Mesh:

Year:  2005        PMID: 16369157     DOI: 10.1097/01.mlg.0000180759.52082.45

Source DB:  PubMed          Journal:  Laryngoscope        ISSN: 0023-852X            Impact factor:   3.325


  24 in total

1.  Device setting modifications for 3D flatpanel imaging in skull base surgery.

Authors:  Frederike Hassepass; Wolfgang Maier; Antje Aschendorff; Stefan Bulla; Werner Vach; Roland Laszig; Tanja D Grauvogel
Journal:  Eur Arch Otorhinolaryngol       Date:  2012-04-06       Impact factor: 2.503

Review 2.  Use of cone beam computed tomography in otolaryngologic treatments.

Authors:  Hamdi Cakli; Cemal Cingi; Yazgi Ay; Fatih Oghan; Torun Ozer; Ercan Kaya
Journal:  Eur Arch Otorhinolaryngol       Date:  2011-09-27       Impact factor: 2.503

3.  Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems.

Authors:  Kwang Nam Jin; Chang Min Park; Jin Mo Goo; Hyun Ju Lee; Youkyung Lee; Jung Im Kim; So Young Choi; Hyo-Cheol Kim
Journal:  Eur Radiol       Date:  2010-09       Impact factor: 5.315

4.  Diagnostic and therapeutic aspects in the treatment of gunshot wounds of the viscerocranium.

Authors:  A Gröbe; J Klatt; M Heiland; R Schmelzle; P Pohlenz
Journal:  Eur J Trauma Emerg Surg       Date:  2010-05-11       Impact factor: 3.693

Review 5.  Advances in imaging of the paranasal sinuses.

Authors:  Francis T K Ling; Stilianos E Kountakis
Journal:  Curr Allergy Asthma Rep       Date:  2006-11       Impact factor: 4.806

6.  Automatic image-to-world registration based on x-ray projections in cone-beam CT-guided interventions.

Authors:  N M Hamming; M J Daly; J C Irish; J H Siewerdsen
Journal:  Med Phys       Date:  2009-05       Impact factor: 4.071

7.  Geometric calibration of a mobile C-arm for intraoperative cone-beam CT.

Authors:  M J Daly; J H Siewerdsen; Y B Cho; D A Jaffray; J C Irish
Journal:  Med Phys       Date:  2008-05       Impact factor: 4.071

8.  [New developments in computer-assisted surgery (CAS). From intraoperative imaging to ultrasound-based navigation].

Authors:  P A Federspil
Journal:  HNO       Date:  2009-10       Impact factor: 1.284

Review 9.  Musculoskeletal applications of flat-panel volume CT.

Authors:  Benjamin Reichardt; Ammar Sarwar; Soenke H Bartling; Arnold Cheung; Michael Grasruck; Christianne Leidecker; Miriam A Bredella; Thomas J Brady; Rajiv Gupta
Journal:  Skeletal Radiol       Date:  2008-04-29       Impact factor: 2.199

10.  Demons deformable registration of CT and cone-beam CT using an iterative intensity matching approach.

Authors:  Sajendra Nithiananthan; Sebastian Schafer; Ali Uneri; Daniel J Mirota; J Webster Stayman; Wojciech Zbijewski; Kristy K Brock; Michael J Daly; Harley Chan; Jonathan C Irish; Jeffrey H Siewerdsen
Journal:  Med Phys       Date:  2011-04       Impact factor: 4.071