Literature DB >> 19390816

Efficacy of a low cost protocol in reducing noise levels in the neonatal intensive care unit.

A Ramesh1, P N Suman Rao, G Sandeep, M Nagapoornima, V Srilakshmi, M Dominic.   

Abstract

OBJECTIVE: To examine the effectiveness and cost of implementing a noise reduction protocol in a level III neonatal intensive care unit (NICU).
METHODS: A prospective longitudinal study was done in a level III NICU, wherein a noise reduction protocol that included behavioral and environmental modification was implemented. The noise levels were measured sequentially every hour for 15 days before and after this intervention. The statistical significance of the reduction in noise levels after implementation of the protocol was tested by paired sample student's t-test. Cost was calculated using the generalized cost effectiveness model of the World Health Organisation. The present study has 80% power with 95% confidence to measure 2 dB differences between groups for the maximum recommended of 50 dB.
RESULTS: The protocol in the present study reduced noise levels in all the rooms of the NICU to within 60 dB with high statistical significance (p< 0.001). The extent of noise reduction in the rooms of the NICU was as follows: ventilator room by 9.58 dB (95% confidence interval: 6.73-12.42, p < 0.001), stable room by 6.54 dB (95% confidence interval: 2.92-4.16, p < 0.001), isolation room by 2.26 dB (95% confidence interval: 1.21-3.30, p < 0.001), pre-term room by 2.37 dB(95% confidence interval: 1.22-3.51, p < 0.001) and extreme preterm room by 2.09 dB (95% confidence interval: 1.14-3.02, p < 0.001). The intervention was most cost-effective in the ventilator room, requiring Rs. 81.09 to reduce 1 dB and least effective in the extreme pre-term room requiring Rs. 371.61 to reduce 1 dB.
CONCLUSION: The high efficacy and affordability of noise reduction protocols justify the need for implementation of these measures as a standard of care in neonatal intensive care units.

Mesh:

Year:  2009        PMID: 19390816     DOI: 10.1007/s12098-009-0066-5

Source DB:  PubMed          Journal:  Indian J Pediatr        ISSN: 0019-5456            Impact factor:   1.967


  10 in total

1.  Excessive noise levels in the neonatal ICU: potential effects on auditory system development.

Authors:  William D T Kent; Andre K W Tan; Maxine C Clarke; Trevor Bardell
Journal:  J Otolaryngol       Date:  2002-12

2.  Broadband transmission noise reduction of smart panels featuring piezoelectric shunt circuits and sound-absorbing material.

Authors:  Jaehwan Kim; Joong-Kuen Lee
Journal:  J Acoust Soc Am       Date:  2002-09       Impact factor: 1.840

3.  Universal hearing screening.

Authors:  P Nagapoornima; A Ramesh; Suman Rao; P L Patricia; Madhuri Gore; M Dominic
Journal:  Indian J Pediatr       Date:  2007-06       Impact factor: 1.967

4.  Spectral analysis of noise in the neonatal intensive care unit.

Authors:  M D Livera; B Priya; A Ramesh; P N Suman Rao; V Srilakshmi; M Nagapoornima; A G Ramakrishnan; M Dominic
Journal:  Indian J Pediatr       Date:  2008-03       Impact factor: 1.967

5.  Peak noise distribution in the neonatal intensive care nursery.

Authors:  A Robertson; C Cooper-Peel; P Vos
Journal:  J Perinatol       Date:  1998 Sep-Oct       Impact factor: 2.521

6.  Establishing a noise measurement protocol for neonatal intensive care units.

Authors:  A Robertson; J Kohn; P Vos; C Cooper-Peel
Journal:  J Perinatol       Date:  1998 Mar-Apr       Impact factor: 2.521

7.  Altering the NICU and measuring infants' responses.

Authors:  M Slevin; N Farrington; G Duffy; L Daly; J F Murphy
Journal:  Acta Paediatr       Date:  2000-05       Impact factor: 2.299

8.  Noise in a neonatal unit: guidelines for the reduction or prevention of noise.

Authors:  N P Nzama; A G Nolte; C S Dörfling
Journal:  Curationis       Date:  1995-06

9.  Environmental noise retards auditory cortical development.

Authors:  Edward F Chang; Michael M Merzenich
Journal:  Science       Date:  2003-04-18       Impact factor: 47.728

10.  Neonatal response to control of noise inside the incubator.

Authors:  A N Johnson
Journal:  Pediatr Nurs       Date:  2001 Nov-Dec
  10 in total
  7 in total

1.  A targeted noise reduction observational study for reducing noise in a neonatal intensive unit.

Authors:  S Chawla; P Barach; M Dwaihy; D Kamat; S Shankaran; B Panaitescu; B Wang; G Natarajan
Journal:  J Perinatol       Date:  2017-06-15       Impact factor: 2.521

2.  Assessment of sound levels in a neonatal intensive care unit in tabriz, iran.

Authors:  Sousan Valizadeh; Mohammad Bagher Hosseini; Nasrinsadat Alavi; Malihe Asadollahi; Siamak Kashefimehr
Journal:  J Caring Sci       Date:  2013-02-26

Review 3.  Environmental noise levels in hospital settings: A rapid review of measurement techniques and implementation in hospital settings.

Authors:  Rory Wallis; Emma Harris; Hyunkook Lee; William Davies; Felicity Astin
Journal:  Noise Health       Date:  2019 Sep-Oct       Impact factor: 0.867

Review 4.  Safe sound exposure in the fetus and preterm infant.

Authors:  Charlene Krueger; Elan Horesh; Brian Adam Crossland
Journal:  J Obstet Gynecol Neonatal Nurs       Date:  2012-03

5.  Sound reduction management in the neonatal intensive care unit for preterm or very low birth weight infants.

Authors:  Abdulraoof Almadhoob; Arne Ohlsson
Journal:  Cochrane Database Syst Rev       Date:  2020-01-27

6.  Music Therapy Intervention in an Open Bay Neonatal Intensive Care Unit Room Is Associated with Less Noise and Higher Signal to Noise Ratios: A Case-Control Study.

Authors:  Shmuel Arnon; Shulamit Epstein; Claire Ghetti; Sofia Bauer-Rusek; Riki Taitelbaum-Swead; Dana Yakobson
Journal:  Children (Basel)       Date:  2022-08-08

7.  Sustaining a "culture of silence" in the neonatal intensive care unit during nonemergency situations: a grounded theory on ensuring adherence to behavioral modification to reduce noise levels.

Authors:  S Swathi; A Ramesh; M Nagapoornima; Lavina M Fernandes; C Jisina; P N Suman Rao; A Swarnarekha
Journal:  Int J Qual Stud Health Well-being       Date:  2014-03-18
  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.