Rory Wallis1, Emma Harris2, Hyunkook Lee1, William Davies3, Felicity Astin2.
Abstract
BACKGROUND: Hospitals provide treatment to improve patient health and well-being but the characteristics of the care environment receive little attention. Excessive noise at night has a negative impact on in-patient health through disturbed sleep. To address this hospital staff must measure night-time environmental noise levels. Therefore, an understanding of environmental noise measurement techniques is required. In this review, we aim to 1) provide a technical overview of factors to consider when measuring environmental noise in hospital settings; 2) conduct a rapid review on the equipment and approaches used to objectively measured noise in hospitals and identify methodological limitations.Entities:
Keywords: Hospital; indoor environment; measurement technique; noise; sound level
Mesh:
Year: 2019 PMID: 32820743 PMCID: PMC7650850 DOI: 10.4103/nah.NAH_19_18
Source DB: PubMed Journal: Noise Health ISSN: 1463-1741 Impact factor: 0.867
Figure 1Flow diagram of search strategy and article selection for systematic search and review modified from Moher et al.[14]
Study characteristics and approaches used to measure hospital noise levels from included studies
| Author | Reporting rating | Setting | Device used | Device location | Time period | Type of amplitude measured | Weighting | Time constant | Calibration | Measurements Made |
|---|---|---|---|---|---|---|---|---|---|---|
| Elliott | Comprehensive | ICU (Australia) | Bruel and Kjaer 2250 SLM (class not stated) | Between 0.75 and 1 m above the patient’s head, 1.75 m above the ground, 1 m below the ceiling, 1.5 m from the wall | 24-hours | Pressure | A, C | Fast | Yes | LAeq, LCpeak, LAmax, LAmin, LCeq, LA90 |
| Liu [ | Comprehensive | NICU (USA) | Larson Davis Spark 706 dosimeter (Type-II) | Bedside (mic 12 inches above the infant’s head), within an incubator (mic halfway between infant’s head and top of incubator), staff work area (suspended from the ceiling, no more than 5 feet above the desk), central entry area (suspended from ceiling, no more than 5 feet above desk) | 24-hours (Leq at 1-s, 1-min, 5-min and hourly intervals, LA10, LA50 and LA90 recorded for 1, 3, 4 and 6-hour intervals) | Pressure | A | Slow | Yes | LAeq, LA10, LA50, LA90 |
| Matook | Comprehensive | NICU (USA) | Quest Sound Pro DL-2 SLM (class not stated) | In a b-ox placed on a shelf in the quadrant of an NICU bay | Two 12-hour recordings (0700-1900 and 1900-0700), 60-s intervals | Pressure | A | Slow | Yes | LAeq, LAmax, LApeak |
| Pope [ | Comprehensive | Medical/surgical nursing units (USA) | Quest Q300 noise dosimeters (class not stated) | Behind the beds of patients with additional measurements made both at nurse’s station and with microphones attached to nurses | 12-hours (0625-1830) | Pressure | A | Slow | Yes | LAeq, LAmin, LAmax, LApeak |
| Short | Comprehensive | Emergency department (Australia) | Digitech QM 1588 SLM (class not stated) | shelf, 1.4 m above the head of patients’ beds in 6 areas − triage, acute, short stay, resuscitation, paediatrics and cubicles | 24-hours at 15-min intervals | Pressure | A | Fast | Yes | LAeq, LAmax, LAmin |
| Memoli | Comprehensive | ICU (UK) | NPL-Minim with MEMS microphones(conforming to Class-I) | Detailed diagram provided of all microphone locations | 30-min continuous recording, with all measurements taken at intervals of 15-min, 1-min and 1-s | Pressure | A | Fast | Yes | LAeq, LAmax, LAmin, LA0.1, LA5, LA10, LA25, LA50, LA75, LA90, LA95 |
| Carvalhais | Comprehensive | NICU (Portugal) | 01 dB model Solo-Premium Class-I SLM (model not stated) | At least 1 m away from the wall at a height between 1 and 1.65 m | 24-hours | Pressure | A, C | Slow | Yes | LAeq, LCpeak, LA90 |
| Knauert | Comprehensive | ICU (USA) | Extech Instruments HD600 SLM (Type-II) | Central location in patient’s room adjacent to the foot of the patient’s bed | 2000-0800, 2000-2359, 0000-0359 and 0400-0800, 10-s intervals | Pressure | A, C | Fast | Yes | LAeq, LCpeak |
| Luetz | Comprehensive | ICU (Germany) | XL2 SLM with M2233 microphone (class and manufacturer not stated) | 40 cm from patient’s head (additional SLMs placed at windows and doors) | 24-hours, 1-min intervals | Pressure | A | Fast | Yes | LAeq, LAmax |
| Fasih-Ramandi and Nadri [ | Comprehensive | ICU (Iran) | Cel 450 SLM (class not stated) | Above the beds | 24-hours, 5-min intervals | Pressure | A | Fast | Yes | LAeq, LAmax, LAmin |
| Santos | Comprehensive | NICUs of 3 hospitals (Portugal) | Solo-Premium Class-I SLM (model not stated) | At least 1 m away from walls/equipment at a height of between 1 and 1.65 m and also inside incubators | 24-hours | Pressure | A, C | Slow | Yes | LAeq, LCpeak |
| McLaren and Maxwell-Armstrong [ | Average | Surgical Wards (UK) | Type 230 Integrating octave band SLM (manufacturer and class not stated) | Entrance to the second bay (consisting of 6 beds), approximately 4 m from the nursing station. | 24-hours (15 minute intervals at 4-hourly time periods), Wednesday-Thursday | Pressure | A | Not stated | Not stated | LAmax, LAeq |
| Nathan | Average | NICU (South Africa) | Type-I SLM (manufacturer and model not stated) | Suspended from the ceiling in each room at a height of 2 m | Two 12-hour intervals in each room (0800 − 2000) on consecutive weekdays | Pressure | A | Not stated | Not stated | LAeq, LAmax, LAmin |
| Chen | Average | NICU (Taiwan) | NL-31 & Rion Co. SLMs (class not stated) | Bedside, away from walls & floor | 24 hours, with hourly data reported | Pressure | A | Slow | Not stated | LAeq, LAmax, LA10, LA90 |
| Lasky and Williams[ | Average | NICU (USA) | Larson Davis Spark 703+ PND (class not stated) | Inside patients’ beds, within 30 cm of their ears | 1-s intervals | Pressure | A | Not stated | Not stated | LAeq |
| Richardson | Average | Wards (UK) | Norsonic NOR-116 SLM (class not stated) | Corner of a 6-bed bay, 1 m from the ground and 1 m from the wall, on a tripod | 24-hours | Pressure | A | Not stated | Yes | LAeq, LApeak |
| Williams | Average | NICU (USA) | Larson Davis Spark 703+ PND (class not stated) | Inside the upper corner of the incubator, 12 inches from the child’s ear | 2-hours (1-s intervals) in the period between 0800 and 1700, ideally between 1000 and 1200 (Monday-Friday) | Pressure | A | Not stated | Yes | dBA SPL |
| Hsu | Average | ICU (Taiwan) | RION NL-22 Type-II SLM | Bedside, 30 cm from the patients’ heads | 42-hours (1-s intervals), divided into seven 6-hour periods | Pressure | A | Not stated | Not stated | LAeq, LAmax, LAmin |
| Hu | Average | ICU (China) | AWAI AWA5610D SLM (class not stated) | Bedside | 24-hours | Pressure | A | Not stated | Not stated | Mean, peak and minimum LpA |
| Lawson | Average | ICU (both in patient rooms and in rooms adjacent to them) (USA) | Bruel and Kjaer SLM (model and class not stated) | Microphone suspended from ceiling (6 inches above bed pillow) | Ten 24-hour periods with 15-min intervals for the LAeq measurement, 10-s intervals for peak measurements | Pressure | A, C | Not stated | Yes | LCpeak, LAeq |
| Gladd and Saunders[ | Average | Treatment room of chemotherapy clinic (USA) | Bruel and Kjaer 2250 SLM (class not stated) | Suspended 1 foot from the ceiling in the centre of each room | 11-hours (daytime), 1-s intervals | Pressure | A, C | Not stated | Yes | LCpeak, LAeq |
| Johansson | Average | ICU (Sweden) | Bruel and Kjaer 2260 SLM (class not stated) | Close to patients’ beds | 24-hours | Pressure | A | Fast | Not stated | LAeq24hours, LAFmax |
| Liu[ | Average | NICU (USA) | Larsen Davis Spark 706 dosimeter (class not stated) | Bedside, 8-12 inches above the infant’s head | 24-hours | Pressure | A | Slow | Not stated | LAmin, LAmax, LA90, LA50, LA10, LAeq |
| Xie and Kang[ | Average | ICU | Solo Type-I SLM (model and class not stated) | 1.2 m height between the wall and patient’s bed (close to the patient’s head), away from reflecting surfaces | 30-min measurements periods throughout the night, 1-s intervals | Pressure | A | Not stated | Not stated | LAeq, LAmax, LA5, LA10, LA50, LA90 & LA95 |
| Zamberlan-Amorim[ | Average | NICU & nursing ward (Brazil) | Quest-400 dosimeter (class not stated) | Central area of each room and suspended 70 cm from the ceiling | Fourteen 12-hour recordings (0700-1900 and 1900-0700) | Pressure | A | Not stated | Not stated | LAeq, LAmax, LApeak |
| Cordova | Average | Burn ICU (USA) | A-weighted SLM (manufacturer, model and class not stated) | Centre of the nurses’ station, 6 m from the patients’ rooms on average, additional measurements within random rooms (near patients’ heads) | 24-hour measurements with 5-s intervals over 1 month | Pressure | A | Not stated | Not stated | LAmax, LAmin, LAeq |
| Darbyshire and Young[ | Average | ICU (UK) | CEL-630 SLM (class not stated) | One SLM central in the room and another near the patients’ heads (patients central to the room were generally chosen) | 24 hours, 1-min intervals | Pressure | A | Not stated | Yes | LApeak, LAeq |
| Ginsberg | Average | Operating theatre (USA) | Thomas Scientific 8331A20 SLM (class not stated) | Flat on the anesthesia machine in the operating room | 2-minute intervals at different points throughout the surgery | Pressure | A | Not stated | Not stated | LAmax |
| Fortes-Garrido | Average | NICU (Spain) | Bruel and Kjaer 2270 & 2250 SLMs (Type-I) | Central in the NICU, 80 cm below the ceiling, 153 cm from the wall in one room & 80/215 in the other | 15 days (1-s intervals) | Pressure | A | Fast | Not stated | LA10, LA50, LA90, LAeq1h |
| Kol | Average | Pediatric ICU (Turkey) | Extech 407780 SLM (class not stated) | At least 1 m away from surfaces and 1-1.5 m away from architectural elements (windows/air vents/ etc.) | 12-hour measurements with 5-s intervals over 1 month | Pressure | A | Not stated | Yes | LAeq, LAmax, LAmin |
| Kol | Average | ICU (Turkey) | Extech 407780 SLM (class not stated) | Between 2 patient’s beds and the nurses’ station, at least 1 m away from surfaces and architectural elements | 24-hours | Pressure | A | Not stated | Yes | LAeq, LAmax, LAmin |
| Hu | Average | ICU (China) | AWAI AWA5610 SLM (class not stated) | Horizontally, 10 cm away from the patient’s auricle | 24-hours, 20-min intervals | Pressure | A | Not stated | Not stated | LAeq |
| Calikusu and Balci[ | Average | NICU (Turkey) | Geartech DT-8852 SLM (class not stated) | On a table in the noisiest area of the ICU (diagram provided in study) | 24-hours, 1-s intervals | Pressure | A | Not stated | Yes | dBA SPL |
| Giv | Average | Operating theatre (Iran) | Noise level gauge | At the location of staff and surgeons | 5-min periods at the start of, during and after surgery | Pressure | A | Not stated | Yes | LAeq, LAeq10, LAeq50, LAeq90, noise pollution level (NPL) |
| Parra | Average | NICU (France) | ACOEM WED noise dosimeter (class not stated) | One microphone in the centre of the room (50 cm from any surface) and another inside the incubator within 30 cm of the ear of each patient | 24-hours, 1-s intervals | Pressure | A | Not stated | Not stated | LAeq, LAmax, LA10 |
| Voigt | Average | ICU (USA) | IC Sentinel (for simultaneous sound and light measurement) | Placed to the left of the patient’s bed, near the head, directly under the main ceiling lights | 1-hour periods, with different times of day simulated | Pressure | A | Not stated | Yes | dBA SPL |
| Akansel and Kaymakci[ | Limited | ICU (Turkey) | Bruel Kjaer 2144 Model Deal Channel Frequency Analyser SLM (class not stated) | Patients’ beds (1.5 m above the floor) | 24 hours (15-min intervals), Monday-Friday | Pressure | A | Not stated | Not stated | Average from individual dBA SPL readings |
| Darcy | Limited | NICU (USA) | Sper Scientific Mini Sound Meter 840014C SLM (class not stated) | Central location for each room (within reason to avoid getting in the way) | 12-hours (day & night periods), 5-min intervals | Pressure | A | Slow | Yes | Average from individual dBA SPL readings |
| Dube | Limited | PCU (USA) | Type-II noise dosimeter (Quest Technologies Q-300), Type-II SLM (Quest Technologies 2900) | Central desk | 24-hours | Pressure | A | Not stated | Yes | Average from individual dBA SPL readings |
| Livera | Limited | NICU (India) | Digital SLM (class not stated) | Single measurements in adjoining rooms of NICUs and hourly measurements in the centre of NICU rooms | Single measurements at 3 AM, additional hourly measurements for 15 days | Pressure | Not stated | Not stated | Not stated | Average from individual dB SPL readings |
| Taylor-Ford | Limited | Surgical Wards (USA) | Quest 2900 SLM (class not stated) | Nursing station, suspended from ceiling | 6 days, 10-min intervals | Pressure | Not stated | Not stated | Not stated | Leq, Lmin, Lmax, L10, L90 |
| Tsara | Limited | ICU (Greece) | Cirrus CR: 245/R2 Environmental Noise Analyser (Type-I) | Noise-monitoring stations placed in each department | 24-hours (divided into three 8-hour periods), 1-hour intervals | Pressure | A | Not stated | Not stated | dBA SPL & LAmax |
| Vinodhkumaradithyaa | Limited | Tertiary Care Hospital (India) | Type-I Digital SLM (Manufacturer and model not stated) | At body level in 14 areas of the hospital | 1-hour (morning & evening periods), 3-min intervals | Pressure | A | Fast | Not stated | LAeq, LA10, LA90, LAmax, LAmin |
| Altuncu | Limited | NICU (Turkey) | 2235 Bruel & Kjaer SLM (class not stated) | Near the head of the infant in the NICU | 5-minute period in the morning, 15-s intervals | Pressure | A | Slow | Not stated | Median from individual LpA readings |
| Macedo | Limited | ICU (Brazil) | Minipa MSL-1532C SLM (class not stated) | Not stated | 2-hour periods for morning, afternoon & night | Pressure | A | Not stated | Not stated | Average from individual dBA SPL readings |
| Ramesh | Limited | NICU (India) | Portable digital SLM (manufacturer, model and class not stated) | Centre of each room in the NICU | Hourly noise measurements over 15 days | Pressure | Not stated | Not stated | used “standard sounds” | Geometric mean of individual LpA readings |
| Dennis | Limited | Emergency Department(USA) | Sper Scientific 8400029 SLM (class not stated) | Central nursing station, entrance of patient’s doorway & next to patient’s right ear | 5-s measurements − 30 mins before & after quiet time and one 1h 30m before the end of quiet time | Pressure | Not stated | Not stated | Not stated | Average from individual LpA readings |
| Juang | Limited | Hospital ward (Taiwan) | Lutron 4030 SLM (class not stated) | 1.5 m above the ground | 1-hour recordings over 5 days between 0830-0930, 1130-1230 and 1600-1700 | Pressure | Not stated | Not stated | Yes | Average from individual dB SPL readings |
| Merilainen | Limited | ICU (Finland) | Not stated | Next to patient’s bed | Not stated | Not stated | Not stated | Not stated | Not stated | Average from individual dB SPL readings |
| Khademi | Limited | Wards of ICU, emergency & kidney transplant departments of hospital (Iran) | EXTECH 407727 SLM (class not stated) | Not Stated | 2-min intervals every 30-mins for 5 days | Pressure | Not stated | Not stated | Yes | Leq, Lpeak |
| Kurmann | Limited | Operating theatre (Switzerland) | PCE 353 SLM (Class not stated) | Directly above the operative field | Measurements taken once per second | Intensity? | Not stated | Not stated | Not stated | dB |
| Li | Limited | Surgical ICU(Taiwan) | TES-1352A-RS232 SLM (class not stated) | 30 cm away from the head of the bed with another on the nurses’ station | Nighttime | Pressure | Not stated | Not stated | Not stated | Average from individual dB SPL readings |
| Linder and Christian[ | Limited | Pediatric oncology unit (USA) | Extech Instruments 407736 digital SLM Type-II (class not stated) | Bedside supply cart for each patient (48 inches from the bed) | 12-hours, 30-s intervals (nighttime) | Pressure | Not stated | Not stated | Yes | dB SPL |
| Olivera | Limited | NICU (Argentina) | Type-II Center 322 Sonometer | In a corner between 2 incubators | 24 hours, 5-s intervals | Pressure | A | Fast | Yes | Average from individual dBA SPL readings |
| Salandin | Limited | ICU (Germany) | Integrated acoustic-level-analyser (DIN EN 60651, Class-I) | “Representative locations of an ICU” | 48-hours | Pressure | A | Fast | Not stated | LAeq, LAmax, LA5, LAmin |
| Van Enk and Steinberg[ | Limited | NICU (USA) | Extech Instruments 407736 dosimeter (class not stated) | Near the patient’s head | Two 30-s readings taken over a 90-s period | Pressure | A | Slow | Not stated | Median from individual dBA SPL readings |
| Elser | Limited | NICU (USA) | Quest Technologies NoiseProDL dosimeter (class not stated) | Within 6 inches of the child’s head in an incubator | 20-mins | Pressure | Not stated | Not stated | Not stated | Leq, Lpeak |
| Guerin | Limited | Pharmacy department (Canada) | Class-II TES 1353 & Class-II Bruel & Kjaer 2240 SLMs mounted on tripods (1.45 m from floor) | Measurements made in 13 zones in the department, 1-5 measurement points were used based on the surface area of each zone | A series of 3-hour periods for both day and night with LAeq recorded at 5-min intervals | Pressure | A | Slow | Yes | LAeq5min |
| Padmakumar | Limited | ICU (UK) | Tecpel DSL-330 SLM (Type-II) | Adjacent to patient’s bedside, 1 m above and to the right of the patient | 24-hours with 3-s intervals | Pressure | A | Fast | Yes | LAmax, LAmin, ’average’ |
| Tegnestedt | Limited | 3 different rooms within an ICU (Sweden) | Spark 706 Larson Davis dosimeter (class not stated) | Behind the headrest of the ICU bed, 1 m from the patient’s head | Five 24-hour periods | Pressure | A,C | Slow for LAeq, fast for Lpeak | Not stated | LAeq, LAmax, Lpeak |
| Verhaert | Limited | Operating theatre (Belgium) | CR110A doseBadge dosimeter & NOR140 sound analyzer (class not stated) | Dosimeter attached to shoulders of surgeon & surgeon’s assistant | Measurement periods between 1h 47m & 2h 49m depending on surgical procedure being measured | Pressure | A,C | Not stated | Yes | LAeq, LCpeak, LA95 |
| Wang | Limited | ICU (USA) | Bruel and Kjaer 2260 SLM (Class not stated) | Nine locations around the ICU, with an additional six in corridors | Six 90-min periods, 8-min intervals | Pressure | A | Not stated | Not stated | LApeak, mean |
| Bano | Limited | Internal medicine ward (Italy) | PCE-222 phonometer | Placed on a 1.4 m high trolley in the middle of each room | 5-min periods, 1-s intervals, during 0730-0830, 1330-1430, 1830-1930 and 2330-0030 | Pressure | A | Not stated | Not stated | Average |
| Filus | Limited | Emergency ward (Brazil) | Bruel and Kjaer 2230 SLM (class not stated) | Carried by evaluator, measurements made at 10 sites in the ER | 2m 30s periods with three repeats for each site throughout the day | Pressure | A | Not stated | Yes | LAmin, LAmax,LAeq |
| Wang | Limited | NICU (Canada) | SoundEar noise meters (class and model not stated) | Single noisemeters placed in each patient area (pod), with another in a central desk area | 2 months, 5-min intervals | Pressure | Not stated | Not stated | Not stated | Leq |
| Wang | Limited | NICU (Canada) | SoundEar noise meters (class and model not stated) | Noisemeters placed in 4 locations in the ward | 2 months, 5-min intervals | Pressure | Not stated | Not stated | Not stated | Leq |
| Hill and LaVela[ | Limited | Patient rooms & nursing stations (USA) | Amprobe SM-20A SLM (class not stated) | 3 patient rooms & 3 nursing substations | 24-hours, 8-min intervals | Pressure | A | Slow | Yes | Average, LAmax, LAmin |
| Watson | Limited | NICU, PICU, CICU (USA) | QuestTechnologies dosimeter (class and model not stated) | Attached to the lapels of patients | Six 4-periods over 24-hours | Pressure | A | Not stated | Not stated | Mean dBA |
| Yelden | Limited | Inpatient neurological rehabilitation unit (UK) | Tecpel 331 SLM(Class-I) | Within 1 m of patient’s bedside at head level and at least 2 m from the door | Six 2-hour periods over 12-hours, 30-s intervals | Pressure | Not stated | Not stated | Not stated | Mean from collected SPL readings |
| Chow and Shellhaas[ | Limited | NICU (USA) | Digital language processor − noise levels extracted using software | On the arm of each infant’s isolette | 16-hour recordings, split into day & night, with 5-min intervals | Not stated | Not stated | Not stated | Not stated | Mean, peak |
| Daraiseh | Limited | Pediatric inpatient units (USA) | QuestTechnologies Noise Pro DL(class not stated) | Dosimeter attached to the shirt collar of nurses (as close to the ear as possible), additional dosimeters attached to the head of patients’ beds | Six 4-hour recordings over a 24-hour period (5-min intervals) | Pressure | A | Not stated | Not stated | Mean from individual readings |
| Kramer | Limited | Pediatric ICU (USA) | QuestTechnologies NoisePRO DLX dosimeter(class not stated) | Microphone 1 m from the patient’s head | 24-hours, 1-min intervals | Pressure | A | Not stated | Yes | Average, LApeak |
| Delaney | Limited | ICU (Australia) | Extech SDL 600 (class not stated) | Nurses’ station & patient’s clinical environment (mounted adjacent to patient’s head, 155 cm away) | 9-hours, 5-s intervals | Pressure | A | Not stated | Not stated | dBA SPL (mean and peak taken from these) |
| Elbaz | Limited | ICU (France) | NoxMedical T3 Microphone (class not stated) | 40 cm from patient’s head | 24-hours, 30-s intervals | Pressure | C | Not stated | Not stated | Took medians from collected SPL data |
| Ramm | Limited | NICU (Australia) | Extech Sound Level Datalogger Dosimeter (class not stated) | Above a sink in a “high traffic area” in each room (0.5 m from the ceiling and 2.16 m from the floor) between 2 bed spaces | 4-weeks, 60-s intervals (day broken down into different periods for analysis) | Pressure | Not stated | Not stated | Not stated | Max, min |
| White and Zomorodi[ | Limited | Nurses’ stations in critical care units (USA) | Decibel 10th iPhone App (version 3.8.1–iPhone model not stated) | Central nurses’ station and individual nurses’ station | Six 30-s periods both for morning and evening | Pressure | Not stated | Not stated | Not stated | Average from individual LpA readings |