Environmental noise levels in hospital settings: A rapid review of measurement techniques and implementation in hospital settings.

Rory Wallis1, Emma Harris2, Hyunkook Lee1, William Davies3, Felicity Astin2.   

Abstract

BACKGROUND: Hospitals provide treatment to improve patient health and well-being but the characteristics of the care environment receive little attention. Excessive noise at night has a negative impact on in-patient health through disturbed sleep. To address this hospital staff must measure night-time environmental noise levels. Therefore, an understanding of environmental noise measurement techniques is required. In this review, we aim to 1) provide a technical overview of factors to consider when measuring environmental noise in hospital settings; 2) conduct a rapid review on the equipment and approaches used to objectively measured noise in hospitals and identify methodological limitations.
DESIGN: : A rapid review of original research articles, from three databases, published since 2008. Studies were included if noise levels were objectively measured in a hospital setting where patients were receiving treatment.
RESULTS: 1429 articles were identified with 76 included in the review. There was significant variability in the approaches used to measure environmental noise in hospitals. Only 14.5% of studies contained sufficient information to support replication of the measurement process. Most studies measured noise levels using a sound level meter positioned closed to a patient's bed area in an intensive care unit.
CONCLUSION: : Unwanted environmental noise in hospital setting impacts negatively on patient and staff health and well-being. However, this literature review found that the approaches used to objectively measure noise level in hospital settings have been inconsistent and poorly reported. Recommendations on best-practice methods to measure noise levels in hospital environments are provided.

Entities:  

Keywords:  Hospital; indoor environment; measurement technique; noise; sound level

Mesh:

Year:  2019        PMID: 32820743      PMCID: PMC7650850          DOI: 10.4103/nah.NAH_19_18

Source DB:  PubMed          Journal:  Noise Health        ISSN: 1463-1741            Impact factor:   0.867


INTRODUCTION

“Noise” is defined as sound that is “unwanted”,[234] with the environments we encounter every day containing numerous noise sources (i.e. “environmental” noise). Hospitals are noisy environments with sounds produced by equipment, the beeping of pagers, the voices of staff and other patients.[5] The effect that excessive levels of such noise can have on patient care has been the topic of much research. Environmental noise can impact patient safety[6]; an extensive review by Pope reported that environmental noise in hospitals affects the sleep of patients, can increase their blood pressure and diminish their immune responses, as well as a host of other negative side effects.[4] The World Health Organization (WHO) issued guidelines on the maximum amount of noise that should be present in hospitals. The guidelines suggest that noise on wards should not exceed 30 dB LAeq, whilst noise in treatment rooms should be kept “as low as possible”.[7] However, studies measuring environmental noise in hospitals have identified that such levels are not realistic. It has been noted that the guidelines did not account for the presence of patients, instead referring to buildings that are “empty”.[4] Moreover, noise levels on nursing units “frequently” exceed 100 dB LAeq, this being the equivalent of a car horn and far removed from the WHO guidelines.[4] Numerous other studies have attempted to quantify the levels of noise in hospitals.[58910] There are a number of limitations when measuring noise in hospitals that make a comparison between studies difficult. [9] Noise levels usually vary rapidly with time and so some form of single-figure or average figure is usually reported. There are many factors to consider in noise measurement and not all are appropriate for hospital noise assessment. They include time period, sampling rate, frequency range, frequency weighting, peak, maximum, percentile levels or energy average. Different measuring devices (e.g. sound level meters and dosimeters) and the different ways in which a device can be calibrated yield different results.[49] The purpose of this rapid review was to describe the equipment and approaches used in studies that objectively measured noise levels in hospitals and identify any associated methodological limitations. Recommendations will be developed to guide the accurate measurement, documentation and reporting of environmental noise measurements in hospitals.

METHODS

A “rapid review” enables an evaluation of existing literature using systematic review methods, whilst allowing for a reduction in the breadth and depth of a full systematic review.[11] The WHO guidelines for rapid reviews states that the literature search can be limited to two or more databases with additional limits on date, language and study design.[12] Although potentially relevant research studies might not be identified using this approach, there is evidence to show that conclusions determined from rapid reviews are similar to conclusions reached in more comprehensive reviews.[13]

Search strategy

Original research articles were identified from three databases (Scopus, PubMed and Cochrane Library) to enable identification of research studies published in both medical and acoustics journals. Input from an Information Technologist enabled us to develop a robust search strategy (see Appendix A) which was piloted. Boolean operators were used to combine search terms relating to “noise” and “hospitals”. Several search limits were applied to reduce the breadth and depth of the review, as permitted by rapid review guidelines.[1112] Searches were limited to English Language only and due to technological advances in sound measurement, were restricted to articles published in the last ten years (≥2008).

Article selection process

Following removal of duplicates, all articles identified from the searches were screened firstly by title/abstract before full-text screening by one author (R.W.) who had expertise in acoustics. Research of any design was included into the review. A random sub-sample of 20 articles considered relevant for inclusion into the review were independently checked against the entry criteria by two authors (E.H. and F.A.). Included studies fulfilled the following criteria; Research studies focusing on environmental noise measurements in hospitals as a primary aim; Studies conducted in a hospital setting; Studies that report objectively measured noise levels using a device which gives an output in decibel (dB); Studies that report indoor levels of noise in areas where patients (adults and children) are being treated (i.e. wards, intensive care units, operating theatres, out-patient clinics); Studies reported in English language.

Data extraction

Data were extracted from all included studies into a tabular format by one author (R.W.). To reduce reporting bias, data from a random sample of 20 studies was independently extracted by another author (WJD) and compared with the original data extraction table. Information extracted included authors, year of publication, setting, noise level measurement device details, location of device, time period of measurements, amplitude type, weight network, time constant, calibrations made and type of noise parameter recorded.

Quality appraisal

The way in which the technical aspects of the included studies were reported was appraised by one author (R.W.). To reduce reporting bias, a random sample of 20 articles were appraised independently by another author (H.L.). Classification of the reporting quality of the studies were based on inclusion of the following variables; the setting; the measuring device used; the location of the device; the time period for the measurement; the type of amplitude measured; the weighting network used; the time constant; the calibration process; and the type of sound level parameter measured (e.g. Leq, Lmax, etc.). Studies were appraised as “comprehensive” if all of these variables were provided in sufficient detail to enable an accurate reproduction of the measurement process; “average” for studies that included information on most of the aforementioned variables, but not all; and “limited” if either vital information was omitted or ambiguities demonstrated in their measurement process, or both. A variable was considered as being “vital” if significant changes in the measurement data could arise if the parameters were changed (this being judged based specifically on the present context of measurements within hospitals). For example, A-weighting in sound pressure level (SPL) measurement attenuates low frequencies heavily with respect to C-weighting and so it is reasonable to suggest that a 24-hour measurement on an ICU with the respective networks applied would yield different results. Given this, failure to indicate the weighting would mean that assumptions would need to be made about the measurement process and this can affect the validity of the data.

RESULTS

Fig. 1 provides an overview of study selection process; 1429 articles were screened (649 from Scopus, 74 from Cochrane and 706 from PubMed), of which, 111 full-texts were assessed for eligibility against inclusion criteria and 76 articles included in the review. The included studies were conducted across 22 countries; USA (26), UK (6), Turkey (5), Taiwan (4), Australia (4), Brazil (3), Canada (3), China (3), India (3), Iran (3), Portugal (2), Germany (2), Sweden (2), France (2), Spain (1), Greece (1), South Africa (1), Finland (1), Switzerland (1), Argentina (1), Belgium (1) and Italy (1).
Figure 1

Flow diagram of search strategy and article selection for systematic search and review modified from Moher et al.[14]

Flow diagram of search strategy and article selection for systematic search and review modified from Moher et al.[14]

Characteristics of the measurement approaches used in studies reporting noise levels in hospitals

Table 1 presents an overview of the study characteristics and measurement approaches used.
Table 1

Study characteristics and approaches used to measure hospital noise levels from included studies

AuthorReporting ratingSettingDevice usedDevice locationTime periodType of amplitude measuredWeightingTime constantCalibrationMeasurements Made
Elliott et al.[15]ComprehensiveICU (Australia)Bruel and Kjaer 2250 SLM (class not stated)Between 0.75 and 1 m above the patient’s head, 1.75 m above the ground, 1 m below the ceiling, 1.5 m from the wall24-hoursPressureA, CFastYesLAeq, LCpeak, LAmax, LAmin, LCeq, LA90
Liu [16] ComprehensiveNICU (USA)Larson Davis Spark 706 dosimeter (Type-II)Bedside (mic 12 inches above the infant’s head), within an incubator (mic halfway between infant’s head and top of incubator), staff work area (suspended from the ceiling, no more than 5 feet above the desk), central entry area (suspended from ceiling, no more than 5 feet above desk)24-hours (Leq at 1-s, 1-min, 5-min and hourly intervals, LA10, LA50 and LA90 recorded for 1, 3, 4 and 6-hour intervals)PressureASlowYesLAeq, LA10, LA50, LA90
Matook et al.[17] ComprehensiveNICU (USA)Quest Sound Pro DL-2 SLM (class not stated)In a b-ox placed on a shelf in the quadrant of an NICU bayTwo 12-hour recordings (0700-1900 and 1900-0700), 60-s intervalsPressureASlowYesLAeq, LAmax, LApeak
Pope [4] ComprehensiveMedical/surgical nursing units (USA)Quest Q300 noise dosimeters (class not stated)Behind the beds of patients with additional measurements made both at nurse’s station and with microphones attached to nurses12-hours (0625-1830)PressureASlowYesLAeq, LAmin, LAmax, LApeak
Short et al. [18] ComprehensiveEmergency department (Australia)Digitech QM 1588 SLM (class not stated)shelf, 1.4 m above the head of patients’ beds in 6 areas − triage, acute, short stay, resuscitation, paediatrics and cubicles24-hours at 15-min intervalsPressureAFastYesLAeq, LAmax, LAmin
Memoli et al.[19] ComprehensiveICU (UK)NPL-Minim with MEMS microphones(conforming to Class-I)Detailed diagram provided of all microphone locations30-min continuous recording, with all measurements taken at intervals of 15-min, 1-min and 1-sPressureAFastYesLAeq, LAmax, LAmin, LA0.1, LA5, LA10, LA25, LA50, LA75, LA90, LA95
Carvalhais et al.[20] ComprehensiveNICU (Portugal)01 dB model Solo-Premium Class-I SLM (model not stated)At least 1 m away from the wall at a height between 1 and 1.65 m24-hoursPressureA, CSlowYesLAeq, LCpeak, LA90
Knauert et al.[21] ComprehensiveICU (USA)Extech Instruments HD600 SLM (Type-II)Central location in patient’s room adjacent to the foot of the patient’s bed2000-0800, 2000-2359, 0000-0359 and 0400-0800, 10-s intervalsPressureA, CFastYesLAeq, LCpeak
Luetz et al. [22] ComprehensiveICU (Germany)XL2 SLM with M2233 microphone (class and manufacturer not stated)40 cm from patient’s head (additional SLMs placed at windows and doors)24-hours, 1-min intervalsPressureAFastYesLAeq, LAmax
Fasih-Ramandi and Nadri [23] ComprehensiveICU (Iran)Cel 450 SLM (class not stated)Above the beds24-hours, 5-min intervalsPressureAFastYesLAeq, LAmax, LAmin
Santos et al.[24] ComprehensiveNICUs of 3 hospitals (Portugal)Solo-Premium Class-I SLM (model not stated)At least 1 m away from walls/equipment at a height of between 1 and 1.65 m and also inside incubators24-hoursPressureA, CSlowYesLAeq, LCpeak
McLaren and Maxwell-Armstrong [25] AverageSurgical Wards (UK)Type 230 Integrating octave band SLM (manufacturer and class not stated)Entrance to the second bay (consisting of 6 beds), approximately 4 m from the nursing station.24-hours (15 minute intervals at 4-hourly time periods), Wednesday-ThursdayPressureANot statedNot statedLAmax, LAeq
Nathan et al. [26] AverageNICU (South Africa)Type-I SLM (manufacturer and model not stated)Suspended from the ceiling in each room at a height of 2 mTwo 12-hour intervals in each room (0800 − 2000) on consecutive weekdaysPressureANot statedNot statedLAeq, LAmax, LAmin
Chen et al. [27] AverageNICU (Taiwan)NL-31 & Rion Co. SLMs (class not stated)Bedside, away from walls & floor24 hours, with hourly data reportedPressureASlowNot statedLAeq, LAmax, LA10, LA90
Lasky and Williams[28] AverageNICU (USA)Larson Davis Spark 703+ PND (class not stated)Inside patients’ beds, within 30 cm of their ears1-s intervalsPressureANot statedNot statedLAeq
Richardson et al.[29] AverageWards (UK)Norsonic NOR-116 SLM (class not stated)Corner of a 6-bed bay, 1 m from the ground and 1 m from the wall, on a tripod24-hoursPressureANot statedYesLAeq, LApeak
Williams et al.[30] AverageNICU (USA)Larson Davis Spark 703+ PND (class not stated)Inside the upper corner of the incubator, 12 inches from the child’s ear2-hours (1-s intervals) in the period between 0800 and 1700, ideally between 1000 and 1200 (Monday-Friday)PressureANot statedYesdBA SPL
Hsu et al.[31] AverageICU (Taiwan)RION NL-22 Type-II SLMBedside, 30 cm from the patients’ heads42-hours (1-s intervals), divided into seven 6-hour periodsPressureANot statedNot statedLAeq, LAmax, LAmin
Hu et al.[32] AverageICU (China)AWAI AWA5610D SLM (class not stated)Bedside24-hoursPressureANot statedNot statedMean, peak and minimum LpA
Lawson et al.[33] AverageICU (both in patient rooms and in rooms adjacent to them) (USA)Bruel and Kjaer SLM (model and class not stated)Microphone suspended from ceiling (6 inches above bed pillow)Ten 24-hour periods with 15-min intervals for the LAeq measurement, 10-s intervals for peak measurementsPressureA, CNot statedYesLCpeak, LAeq
Gladd and Saunders[34] AverageTreatment room of chemotherapy clinic (USA)Bruel and Kjaer 2250 SLM (class not stated)Suspended 1 foot from the ceiling in the centre of each room11-hours (daytime), 1-s intervalsPressureA, CNot statedYesLCpeak, LAeq
Johansson et al.[35] AverageICU (Sweden)Bruel and Kjaer 2260 SLM (class not stated)Close to patients’ beds24-hoursPressureAFastNot statedLAeq24hours, LAFmax
Liu[36] AverageNICU (USA)Larsen Davis Spark 706 dosimeter (class not stated)Bedside, 8-12 inches above the infant’s head24-hoursPressureASlowNot statedLAmin, LAmax, LA90, LA50, LA10, LAeq
Xie and Kang[37] AverageICUSolo Type-I SLM (model and class not stated)1.2 m height between the wall and patient’s bed (close to the patient’s head), away from reflecting surfaces30-min measurements periods throughout the night, 1-s intervalsPressureANot statedNot statedLAeq, LAmax, LA5, LA10, LA50, LA90 & LA95
Zamberlan-Amorim[38] AverageNICU & nursing ward (Brazil)Quest-400 dosimeter (class not stated)Central area of each room and suspended 70 cm from the ceilingFourteen 12-hour recordings (0700-1900 and 1900-0700)PressureANot statedNot statedLAeq, LAmax, LApeak
Cordova et al.[39] AverageBurn ICU (USA)A-weighted SLM (manufacturer, model and class not stated)Centre of the nurses’ station, 6 m from the patients’ rooms on average, additional measurements within random rooms (near patients’ heads)24-hour measurements with 5-s intervals over 1 monthPressureANot statedNot statedLAmax, LAmin, LAeq
Darbyshire and Young[40] AverageICU (UK)CEL-630 SLM (class not stated)One SLM central in the room and another near the patients’ heads (patients central to the room were generally chosen)24 hours, 1-min intervalsPressureANot statedYesLApeak, LAeq
Ginsberg et al.[41] AverageOperating theatre (USA)Thomas Scientific 8331A20 SLM (class not stated)Flat on the anesthesia machine in the operating room2-minute intervals at different points throughout the surgeryPressureANot statedNot statedLAmax
Fortes-Garrido et al.[42] AverageNICU (Spain)Bruel and Kjaer 2270 & 2250 SLMs (Type-I)Central in the NICU, 80 cm below the ceiling, 153 cm from the wall in one room & 80/215 in the other15 days (1-s intervals)PressureAFastNot statedLA10, LA50, LA90, LAeq1h
Kol et al. [43] AveragePediatric ICU (Turkey)Extech 407780 SLM (class not stated)At least 1 m away from surfaces and 1-1.5 m away from architectural elements (windows/air vents/ etc.)12-hour measurements with 5-s intervals over 1 monthPressureANot statedYesLAeq, LAmax, LAmin
Kol et al.[44] AverageICU (Turkey)Extech 407780 SLM (class not stated)Between 2 patient’s beds and the nurses’ station, at least 1 m away from surfaces and architectural elements24-hoursPressureANot statedYesLAeq, LAmax, LAmin
Hu et al.[45] AverageICU (China)AWAI AWA5610 SLM (class not stated)Horizontally, 10 cm away from the patient’s auricle24-hours, 20-min intervalsPressureANot statedNot statedLAeq
Calikusu and Balci[46] AverageNICU (Turkey)Geartech DT-8852 SLM (class not stated)On a table in the noisiest area of the ICU (diagram provided in study)24-hours, 1-s intervalsPressureANot statedYesdBA SPL
Giv et al.[47] AverageOperating theatre (Iran)Noise level gaugeAt the location of staff and surgeons5-min periods at the start of, during and after surgeryPressureANot statedYesLAeq, LAeq10, LAeq50, LAeq90, noise pollution level (NPL)
Parra et al.[48] AverageNICU (France)ACOEM WED noise dosimeter (class not stated)One microphone in the centre of the room (50 cm from any surface) and another inside the incubator within 30 cm of the ear of each patient24-hours, 1-s intervalsPressureANot statedNot statedLAeq, LAmax, LA10
Voigt et al.[49] AverageICU (USA)IC Sentinel (for simultaneous sound and light measurement)Placed to the left of the patient’s bed, near the head, directly under the main ceiling lights1-hour periods, with different times of day simulatedPressureANot statedYesdBA SPL
Akansel and Kaymakci[50] LimitedICU (Turkey)Bruel Kjaer 2144 Model Deal Channel Frequency Analyser SLM (class not stated)Patients’ beds (1.5 m above the floor)24 hours (15-min intervals), Monday-FridayPressureANot statedNot statedAverage from individual dBA SPL readings
Darcy et al.[51] LimitedNICU (USA)Sper Scientific Mini Sound Meter 840014C SLM (class not stated)Central location for each room (within reason to avoid getting in the way)12-hours (day & night periods), 5-min intervalsPressureASlowYesAverage from individual dBA SPL readings
Dube et al.[9] LimitedPCU (USA)Type-II noise dosimeter (Quest Technologies Q-300), Type-II SLM (Quest Technologies 2900)Central desk24-hoursPressureANot statedYesAverage from individual dBA SPL readings
Livera et al.[52] LimitedNICU (India)Digital SLM (class not stated)Single measurements in adjoining rooms of NICUs and hourly measurements in the centre of NICU roomsSingle measurements at 3 AM, additional hourly measurements for 15 daysPressureNot statedNot statedNot statedAverage from individual dB SPL readings
Taylor-Ford et al.[53] LimitedSurgical Wards (USA)Quest 2900 SLM (class not stated)Nursing station, suspended from ceiling6 days, 10-min intervalsPressureNot statedNot statedNot statedLeq, Lmin, Lmax, L10, L90
Tsara et al.[54] LimitedICU (Greece)Cirrus CR: 245/R2 Environmental Noise Analyser (Type-I)Noise-monitoring stations placed in each department24-hours (divided into three 8-hour periods), 1-hour intervalsPressureANot statedNot stateddBA SPL & LAmax
Vinodhkumaradithyaa et al.[55] LimitedTertiary Care Hospital (India)Type-I Digital SLM (Manufacturer and model not stated)At body level in 14 areas of the hospital1-hour (morning & evening periods), 3-min intervalsPressureAFastNot statedLAeq, LA10, LA90, LAmax, LAmin
Altuncu et al.[56] LimitedNICU (Turkey)2235 Bruel & Kjaer SLM (class not stated)Near the head of the infant in the NICU5-minute period in the morning, 15-s intervalsPressureASlowNot statedMedian from individual LpA readings
Macedo et al.[57] LimitedICU (Brazil)Minipa MSL-1532C SLM (class not stated)Not stated2-hour periods for morning, afternoon & nightPressureANot statedNot statedAverage from individual dBA SPL readings
Ramesh et al.[58] LimitedNICU (India)Portable digital SLM (manufacturer, model and class not stated)Centre of each room in the NICUHourly noise measurements over 15 daysPressureNot statedNot statedused “standard sounds”Geometric mean of individual LpA readings
Dennis et al.[59] LimitedEmergency Department(USA)Sper Scientific 8400029 SLM (class not stated)Central nursing station, entrance of patient’s doorway & next to patient’s right ear5-s measurements − 30 mins before & after quiet time and one 1h 30m before the end of quiet timePressureNot statedNot statedNot statedAverage from individual LpA readings
Juang et al.[60] LimitedHospital ward (Taiwan)Lutron 4030 SLM (class not stated)1.5 m above the ground1-hour recordings over 5 days between 0830-0930, 1130-1230 and 1600-1700PressureNot statedNot statedYesAverage from individual dB SPL readings
Merilainen et al.[61] LimitedICU (Finland)Not statedNext to patient’s bedNot statedNot statedNot statedNot statedNot statedAverage from individual dB SPL readings
Khademi et al.[62] LimitedWards of ICU, emergency & kidney transplant departments of hospital (Iran)EXTECH 407727 SLM (class not stated)Not Stated2-min intervals every 30-mins for 5 daysPressureNot statedNot statedYesLeq, Lpeak
Kurmann et al.[63] LimitedOperating theatre (Switzerland)PCE 353 SLM (Class not stated)Directly above the operative fieldMeasurements taken once per secondIntensity?Not statedNot statedNot stateddB
Li et al. [64] LimitedSurgical ICU(Taiwan)TES-1352A-RS232 SLM (class not stated)30 cm away from the head of the bed with another on the nurses’ stationNighttimePressureNot statedNot statedNot statedAverage from individual dB SPL readings
Linder and Christian[65] LimitedPediatric oncology unit (USA)Extech Instruments 407736 digital SLM Type-II (class not stated)Bedside supply cart for each patient (48 inches from the bed)12-hours, 30-s intervals (nighttime)PressureNot statedNot statedYesdB SPL
Olivera et al.[66] LimitedNICU (Argentina)Type-II Center 322 SonometerIn a corner between 2 incubators24 hours, 5-s intervalsPressureAFastYesAverage from individual dBA SPL readings
Salandin et al.[10] LimitedICU (Germany)Integrated acoustic-level-analyser (DIN EN 60651, Class-I)“Representative locations of an ICU”48-hoursPressureAFastNot statedLAeq, LAmax, LA5, LAmin
Van Enk and Steinberg[67] LimitedNICU (USA)Extech Instruments 407736 dosimeter (class not stated)Near the patient’s headTwo 30-s readings taken over a 90-s periodPressureASlowNot statedMedian from individual dBA SPL readings
Elser et al.[68] LimitedNICU (USA)Quest Technologies NoiseProDL dosimeter (class not stated)Within 6 inches of the child’s head in an incubator20-minsPressureNot statedNot statedNot statedLeq, Lpeak
Guerin et al.[69] LimitedPharmacy department (Canada)Class-II TES 1353 & Class-II Bruel & Kjaer 2240 SLMs mounted on tripods (1.45 m from floor)Measurements made in 13 zones in the department, 1-5 measurement points were used based on the surface area of each zoneA series of 3-hour periods for both day and night with LAeq recorded at 5-min intervalsPressureASlowYesLAeq5min
Padmakumar et al.[70] LimitedICU (UK)Tecpel DSL-330 SLM (Type-II)Adjacent to patient’s bedside, 1 m above and to the right of the patient24-hours with 3-s intervalsPressureAFastYesLAmax, LAmin, ’average’
Tegnestedt et al.[71] Limited3 different rooms within an ICU (Sweden)Spark 706 Larson Davis dosimeter (class not stated)Behind the headrest of the ICU bed, 1 m from the patient’s headFive 24-hour periodsPressureA,CSlow for LAeq, fast for LpeakNot statedLAeq, LAmax, Lpeak
Verhaert et al.[72] LimitedOperating theatre (Belgium)CR110A doseBadge dosimeter & NOR140 sound analyzer (class not stated)Dosimeter attached to shoulders of surgeon & surgeon’s assistantMeasurement periods between 1h 47m & 2h 49m depending on surgical procedure being measuredPressureA,CNot statedYesLAeq, LCpeak, LA95
Wang et al.[73] LimitedICU (USA)Bruel and Kjaer 2260 SLM (Class not stated)Nine locations around the ICU, with an additional six in corridorsSix 90-min periods, 8-min intervalsPressureANot statedNot statedLApeak, mean
Bano et al.[74] LimitedInternal medicine ward (Italy)PCE-222 phonometerPlaced on a 1.4 m high trolley in the middle of each room5-min periods, 1-s intervals, during 0730-0830, 1330-1430, 1830-1930 and 2330-0030PressureANot statedNot statedAverage
Filus et al.[75] LimitedEmergency ward (Brazil)Bruel and Kjaer 2230 SLM (class not stated)Carried by evaluator, measurements made at 10 sites in the ER2m 30s periods with three repeats for each site throughout the dayPressureANot statedYesLAmin, LAmax,LAeq
Wang et al.[76] LimitedNICU (Canada)SoundEar noise meters (class and model not stated)Single noisemeters placed in each patient area (pod), with another in a central desk area2 months, 5-min intervalsPressureNot statedNot statedNot statedLeq
Wang et al.[77] LimitedNICU (Canada)SoundEar noise meters (class and model not stated)Noisemeters placed in 4 locations in the ward2 months, 5-min intervalsPressureNot statedNot statedNot statedLeq
Hill and LaVela[78] LimitedPatient rooms & nursing stations (USA)Amprobe SM-20A SLM (class not stated)3 patient rooms & 3 nursing substations24-hours, 8-min intervalsPressureASlowYesAverage, LAmax, LAmin
Watson et al.[79] LimitedNICU, PICU, CICU (USA)QuestTechnologies dosimeter (class and model not stated)Attached to the lapels of patientsSix 4-periods over 24-hoursPressureANot statedNot statedMean dBA
Yelden et al.[80] LimitedInpatient neurological rehabilitation unit (UK)Tecpel 331 SLM(Class-I)Within 1 m of patient’s bedside at head level and at least 2 m from the doorSix 2-hour periods over 12-hours, 30-s intervalsPressureNot statedNot statedNot statedMean from collected SPL readings
Chow and Shellhaas[81] LimitedNICU (USA)Digital language processor − noise levels extracted using softwareOn the arm of each infant’s isolette16-hour recordings, split into day & night, with 5-min intervalsNot statedNot statedNot statedNot statedMean, peak
Daraiseh et al.[82] LimitedPediatric inpatient units (USA)QuestTechnologies Noise Pro DL(class not stated)Dosimeter attached to the shirt collar of nurses (as close to the ear as possible), additional dosimeters attached to the head of patients’ bedsSix 4-hour recordings over a 24-hour period (5-min intervals)PressureANot statedNot statedMean from individual readings
Kramer et al.[83] LimitedPediatric ICU (USA)QuestTechnologies NoisePRO DLX dosimeter(class not stated)Microphone 1 m from the patient’s head24-hours, 1-min intervalsPressureANot statedYesAverage, LApeak
Delaney et al.[84] LimitedICU (Australia)Extech SDL 600 (class not stated)Nurses’ station & patient’s clinical environment (mounted adjacent to patient’s head, 155 cm away)9-hours, 5-s intervalsPressureANot statedNot stateddBA SPL (mean and peak taken from these)
Elbaz et al.[85] LimitedICU (France)NoxMedical T3 Microphone (class not stated)40 cm from patient’s head24-hours, 30-s intervalsPressureCNot statedNot statedTook medians from collected SPL data
Ramm et al.[86] LimitedNICU (Australia)Extech Sound Level Datalogger Dosimeter (class not stated)Above a sink in a “high traffic area” in each room (0.5 m from the ceiling and 2.16 m from the floor) between 2 bed spaces4-weeks, 60-s intervals (day broken down into different periods for analysis)PressureNot statedNot statedNot statedMax, min
White and Zomorodi[87] LimitedNurses’ stations in critical care units (USA)Decibel 10th iPhone App (version 3.8.1–iPhone model not stated)Central nurses’ station and individual nurses’ stationSix 30-s periods both for morning and eveningPressureNot statedNot statedNot statedAverage from individual LpA readings
Study characteristics and approaches used to measure hospital noise levels from included studies Of the 76 studies that measured environmental noise in hospitals since 2008, noise levels were most commonly measured in an intensive care unit (70% of studies), while the remaining studies reported noise levels in emergency departments, patient wards, operating theatres, a pharmacy department or multiple locations around a hospital. The majority of studies (66%) used some form of Sound Level Meter (SLM), whilst a further 20% used dosimeters to measure noise levels in a hospital setting. There was a large amount of variation in the location of the measuring device between studies, with 47% of studies using the area around the patient’s bed as the location for recording noise measurements. Furthermore, the measurement durations varied widely, with numerous studies recording both day and night noise levels and at different periods of time throughout the day. The majority of studies (96%) explicitly stated that SPLs were measured and 66% of studies used an A-weighting network. The most popular measurement method was the time-average SPL (Leq), being present in 58% of all studies. Lmax (maximum SPL) and Lmin (minimum SPL) were also popular (38% and 28% respectively). The arithmetic “average” of sound levels was calculated in 26% of all studies, but details on this calculation were ambiguous. Each study using this approach was rated as “limited” for reporting quality.

Quality appraisal of measurement approaches

The way in which the technical aspects of the included studies was reported was appraised as “comprehensive” for 11 studies, “average” for 25 studies and “limited” for 40 studies. This means that only 14.5% of the 76 hospital studies included in the review, provided sufficient details to enable the authors to repeat the measurement. A high proportion of studies were able to provide sufficient information about the measurement process in some areas. With respect to the time periods in which the measurements were conducted, 97% of all studies provided information on both the duration of the measurement process and also the sampling period for measurements. Similarly, most studies (87%) also provided details about the specific location of the measuring instruments. However, it is important to note that there were a number of key absences across the studies. The time constant, for example, was only discussed in 33% of all studies, whilst only 43% provided information about the calibration process. Moreover, although the details on the frequency weighting function used in the respective studies was generally present, with 78% of studies including this information (65.8% for A-weighting, 10.5% for C-weighting and 1.3% for both), 22% were not explicit as to which network was used.

Recommendations

Based on this review, the following recommendations are provided to guide the accurate measurement and documentation of environmental noise measurements in hospitals. Purpose. A noise survey may have a variety of different approaches and the specific purpose should be identified. The noise survey may be designed to assess the noise exposure at specific patient bed spaces, noise exposure of staff or measuring the noise climate of specific rooms or types of setting. The measurements may be made to assess compliance with a benchmark (such as WHO) or to compare with environmental noise levels across similar settings or as part of a noise reduction programme. SLM setting. The purpose of the noise survey will determine the choice of instrumentation. Currently there is no standardised method for measuring hospital noise. Modern sound level meters are often capable of measuring many different acoustic metrics. The accuracy and comparability of all of these metrics is not guaranteed, not least because permitted tolerances of sound level meters are defined for a limited range of metrics.[1] This makes it difficult for the non-specialist to know what to measure and why. Many of the studies included in this review compared their results to the WHO guidelines, which are expressed in LAeq (A-weighted time-average SPL) and LAFmax (A-weighted maximum SPL measured over a given period of time with ‘fast’ time constant (i.e. 125ms)). For most long-term measurement applications in a hospital environment, A-weighting would be most appropriate since it considers the frequency-dependent loudness perception of the human hearing system (i.e. LAeq). There are large meta-analyses of outdoor environmental noise which indicate that variants of LAeq are an adequate predictor of noise annoyance.[88] Care should be exercised when attempting to measure the maximum SPL, for three main reasons. Firstly, even if a researcher considers a maximum value to be representative of a distribution of noise levels measured in a location, it is unlikely to be generalisable. For example, if a hospital ward measurement is repeated on the next night, a different maximum value will likely occur. Secondly, there are several different ways of measuring a maximum value. For example, Lpeak means decibel value corresponding to the maximum pressure (positive or negative) arriving at the microphone,[1] while LAFmax means the maximum A-weighted SPL measured with a Fast time constant. Lpeak will typically be many decibels higher than LAFmax. Finally, the evidence relating measured maxima to human responses is not as strong as for average values like LAeq, at least for noise exposures below the range where noise-induced hearing loss is likely. This is reflected in the widespread use of LCpeak in workplace noise exposure legislation, but not in standardised methods intended to predict annoyance or disturbance from noise. If it is desired to measure the maximum SPL, it is recommended that the device be set to ‘fast’ and A-weighted (i.e. LAFmax). This would allow comparison with WHO guidelines. LA10 (SPL exceeded for 10% of the measurement time period) and LA90 (SPL exceeded for 90% of the measurement time period) would be useful alternative metrics. They are widely used in environmental noise surveys as markers of the near-highest and background sound levels, respectively. Measured over day, night or 24-hour periods, they might also be useful measures of the noise climate on a hospital ward. Locations. The positioning of the measuring device should be made sufficient for the “point-of-interest” for your study. For example, if a patient’s noise exposure is of interest, then a location close to the patient’s ear will be more appropriate than a central location in the room. The measuring device should be positioned in a location that is not disruptive to the day-to-day clinical activity of the hospital staff. Any contact with the measuring device during measurements should be avoided as this can affect the maximum SPL to be recorded. Compromises may be required to balance preferences for the ideal location for the point-of-interest with practical considerations. It is important to ensure that any measuring devices are at least 1 m (more if possible) away from any large reflecting surfaces (doors, walls, windows, floors, ceilings, etc.) and that they are on a stable surface, such as being mounted on a tripod. Close reflecting surfaces will increase the measured sound level, dependent on several factors which make the result less generalisable, like the size and acoustic absorption coefficient of the surface. Documentation and reporting. It is essential to be explicit about the procedure that was followed and equipment used. Failure to document this information can cause the measurement data to be uninterpretable and meaningless. The provision of detailed information will avoid any unnecessary confusion and support the perceived accuracy of your results. The essential information to be reported is as follows: The precise location of the measuring device, using a picture or diagram if necessary. The time period and sampling intervals for the measurement. Equipment manufacturer and model. Equipment calibration process. Time constant and frequency weighting (e.g. LAeq, LAFmax, LA90, etc.). Data analysis. Researchers should exercise caution when attempting to manipulate the measurement data and avoid this where possible. Instead, all desired measurements and results should ideally come directly from the measuring instrument, and any supporting software, in order to minimise data errors. To calculate the “average” environmental noise level when this is not achievable with the instrumentation at your disposal, then the calculation of the arithmetic mean is not recommended because this does not produce an Leq. Instead, the Leq should be estimated from the measured data and the process used to do described in detail. To avoid confusion the use of the term “average” in this context should be avoided.

CONCLUSION

This rapid review of 76 studies provides a detailed overview of the equipment and approaches used in studies that have measured noise levels in hospitals. There was significant variability in the approaches used to measure environmental noise in hospitals. Few studies (14.5%) contained sufficient technical information to support the replication of the environmental noise measurement process; descriptions on important parameters such as weighting, time constant and measurement time period were missing. In hospital environments, it is recommended to use LAeq or LAFmax. The measurement equipment setting and process should be fully documented with details on device location and the time period of the recording noted. Attempts to average any measured data should be avoided where possible. In addition, most studies measured noise levels using a SLM positioned closed to a patient’s bed area in an intensive care unit. It is recommended future studies also measure noise levels in other areas of a hospital such as in-patient wards, where the impact of noise can have a negative impact on patients’ health.

Financial support and sponsorship

Nil.

Conflicts of interest

There are no conflicts of interest.
  75 in total

1.  Decibel levels and noise generators on four medical/surgical nursing units.

Authors:  Diana Pope
Journal:  J Clin Nurs       Date:  2010-09       Impact factor: 3.036

2.  A rehabilitation unit at night: environmental characteristics of patient rooms.

Authors:  Kudret Yelden; Sophie Duport; Agnieszka Kempny; E Diane Playford
Journal:  Disabil Rehabil       Date:  2014-04-01       Impact factor: 3.033

3.  The acoustic environment of intensive care wards based on long period nocturnal measurements.

Authors:  Hui Xie; Jian Kang
Journal:  Noise Health       Date:  2012 Sep-Oct       Impact factor: 0.867

4.  Noise exposure of care providers during otosurgical procedures.

Authors:  N Verhaert; N Moyaert; L Godderis; F Debruyne; C Desloovere; H Luts
Journal:  B-ENT       Date:  2013       Impact factor: 0.082

Review 5.  Noise in the operating room.

Authors:  Jonathan D Katz
Journal:  Anesthesiology       Date:  2014-10       Impact factor: 7.892

6.  24-hour intensive care: an observational study of an environment and events.

Authors:  Merja Meriläinen; Helvi Kyngäs; Tero Ala-Kokko
Journal:  Intensive Crit Care Nurs       Date:  2010-07-24       Impact factor: 3.072

7.  Noise levels in a burn intensive care unit.

Authors:  Alfredo C Cordova; Kartik Logishetty; James Fauerbach; Leigh A Price; B Robert Gibson; Stephen M Milner
Journal:  Burns       Date:  2012-04-27       Impact factor: 2.744

8.  Noise Levels in Patient Rooms and at Nursing Stations at Three VA Medical Centers.

Authors:  Jennifer N Hill; Sherri L LaVela
Journal:  HERD       Date:  2015-07-10

9.  An investigation of sound levels on intensive care units with reference to the WHO guidelines.

Authors:  Julie L Darbyshire; J Duncan Young
Journal:  Crit Care       Date:  2013-09-03       Impact factor: 9.097

10.  Noise assessment in intensive care units.

Authors:  Ivan Senis Cardoso Macedo; Daniela Cunha Mateus; Eduardo De Martin Guedes C Costa; Ana Cristina Lanfranchi Asprino; Edmir Américo Lourenço
Journal:  Braz J Otorhinolaryngol       Date:  2009 Nov-Dec
View more
  2 in total

1.  Noise in the operating theatre.

Authors:  T Hampton; S Everett; S Sharma; M Krishnan
Journal:  Br J Surg       Date:  2021-05-27       Impact factor: 6.939

2.  Methods for Measuring and Identifying Sounds in the Intensive Care Unit.

Authors:  Aileen C Naef; Samuel E J Knobel; Nicole Ruettgers; Marie-Madlen Jeitziner; Martin Grosse Holtforth; Bjoern Zante; Joerg C Schefold; Tobias Nef; Stephan M Gerber
Journal:  Front Med (Lausanne)       Date:  2022-06-06
  2 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.