Literature DB >> 12593547

Excessive noise levels in the neonatal ICU: potential effects on auditory system development.

William D T Kent1, Andre K W Tan, Maxine C Clarke, Trevor Bardell.   

Abstract

OBJECTIVE: Several recent studies have found exceedingly high noise levels in the neonatal intensive care unit (NICU) and in incubators. The purpose of this study was to perform a detailed noise assessment in a Canadian NICU.
METHODS: A noise level meter was used to evaluate ambient noise levels in three rooms of the NICU and to compare those levels with measurements taken inside an occupied incubator.
RESULTS: Mean hourly noise levels measured inside the incubator (61 dB) were significantly higher than those measured outside (55 dB). Ambient noise levels were also significantly higher in rooms where staff activity was greatest (59 dB). In addition, peak noise levels in excess of 120 dB were found.
CONCLUSION: These findings are consistent with those of previous studies and suggest that noise levels in the NICU are excessive. Furthermore, staff activity is a significant contributor. The suggestion that noise in the NICU is detrimental to both auditory and central nervous system development is discussed and intervention strategies are recommended.

Entities:  

Mesh:

Year:  2002        PMID: 12593547     DOI: 10.2310/7070.2002.34358

Source DB:  PubMed          Journal:  J Otolaryngol        ISSN: 0381-6605


  12 in total

1.  Efficacy of a low cost protocol in reducing noise levels in the neonatal intensive care unit.

Authors:  A Ramesh; P N Suman Rao; G Sandeep; M Nagapoornima; V Srilakshmi; M Dominic
Journal:  Indian J Pediatr       Date:  2009-04-23       Impact factor: 1.967

2.  The sound intensity and characteristics of variable-pitch pulse oximeters.

Authors:  Hiroo Yamanaka; Junichi Haruna; Takashi Mashimo; Takeshi Akita; Keiko Kinouchi
Journal:  J Clin Monit Comput       Date:  2008-05-16       Impact factor: 2.502

Review 3.  Impact of hospital-based environmental exposures on neurodevelopmental outcomes of preterm infants.

Authors:  Janelle Santos; Sarah E Pearce; Annemarie Stroustrup
Journal:  Curr Opin Pediatr       Date:  2015-04       Impact factor: 2.856

Review 4.  Enhancing sensory experiences for very preterm infants in the NICU: an integrative review.

Authors:  R Pineda; R Guth; A Herring; L Reynolds; S Oberle; J Smith
Journal:  J Perinatol       Date:  2016-10-20       Impact factor: 2.521

5.  Infant neurobehavioral development.

Authors:  Barry M Lester; Robin J Miller; Katheleen Hawes; Amy Salisbury; Rosemarie Bigsby; Mary C Sullivan; James F Padbury
Journal:  Semin Perinatol       Date:  2011-02       Impact factor: 3.300

6.  Divergence of noise vulnerability in cochleae of young CBA/J and CBA/CaJ mice.

Authors:  Kevin K Ohlemiller; Mary E Rybak Rice; Erin A Rellinger; Amanda J Ortmann
Journal:  Hear Res       Date:  2010-11-23       Impact factor: 3.208

7.  Assessment of ambient noise levels in the intensive care unit of a university hospital.

Authors:  Hatem O Qutub; Khaled F El-Said
Journal:  J Family Community Med       Date:  2009-05

8.  Sound reduction management in the neonatal intensive care unit for preterm or very low birth weight infants.

Authors:  Abdulraoof Almadhoob; Arne Ohlsson
Journal:  Cochrane Database Syst Rev       Date:  2020-01-27

9.  An acoustic gap between the NICU and womb: a potential risk for compromised neuroplasticity of the auditory system in preterm infants.

Authors:  Amir Lahav; Erika Skoe
Journal:  Front Neurosci       Date:  2014-12-05       Impact factor: 4.677

10.  Efficacy of noise reduction bundle in reducing sound levels in a Level II neonatal care unit in China.

Authors:  Liyuan Hu; Qing Liu; Hao Yuan; Chunmei Lu; Wenhao Zhou
Journal:  Transl Pediatr       Date:  2020-12
View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.