Literature DB >> 28617421

A targeted noise reduction observational study for reducing noise in a neonatal intensive unit.

S Chawla1, P Barach1, M Dwaihy1, D Kamat1, S Shankaran1, B Panaitescu1, B Wang1, G Natarajan1.   

Abstract

BACKGROUND: Excessive noise in neonatal intensive care units (NICUs) can interfere with infants' growth, development and healing.Local problem:Sound levels in our NICUs exceeded the recommended levels by the World Health Organization.
METHODS: We implemented a noise reduction strategy in an urban, tertiary academic medical center NICU that included baseline noise measurements. We conducted a survey involving staff and visitors regarding their opinions and perceptions of noise levels in the NICU. Ongoing feedback to staff after each measurement cycle was provided to improve awareness, engagement and adherence with noise reduction strategies. After widespread discussion with active clinician involvement, consensus building and iterative testing, changes were implemented including: lowering of equipment alarm sounds, designated 'quiet times' and implementing a customized education program for staff.
INTERVENTIONS: A multiphase noise reduction quality improvement (QI) intervention to reduce ambient sound levels in a patient care room in our NICUs by 3 dB (20%) over 18 months.
RESULTS: The noise in the NICU was reduced by 3 dB from baseline. Mean (s.d.) baseline, phase 2, 3 and 4 noise levels in the two NICUs were: LAeq: 57.0 (0.84), 56.8 (1.6), 55.3 (1.9) and 54.5 (2.6) dB, respectively (P<0.01). Adherence with the planned process measure of 'quiet times' was >90%.
CONCLUSIONS: Implementing a multipronged QI initiative resulted in significant noise level reduction in two multipod NICUs. It is feasible to reduce noise levels if QI interventions are coupled with active engagement of the clinical staff and following continuous process of improvement methods, measurements and protocols.

Entities:  

Mesh:

Year:  2017        PMID: 28617421     DOI: 10.1038/jp.2017.93

Source DB:  PubMed          Journal:  J Perinatol        ISSN: 0743-8346            Impact factor:   2.521


  30 in total

1.  Effects of intense noise exposure on fetal sheep auditory brain stem response and inner ear histology.

Authors:  K J Gerhardt; L L Pierson; X Huang; R M Abrams; K E Rarey
Journal:  Ear Hear       Date:  1999-02       Impact factor: 3.570

Review 2.  The effects of noise on preterm infants in the NICU.

Authors:  Elisha M Wachman; Amir Lahav
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2010-06-14       Impact factor: 5.747

3.  Noise and light exposures for extremely low birth weight newborns during their stay in the neonatal intensive care unit.

Authors:  Robert E Lasky; Amber L Williams
Journal:  Pediatrics       Date:  2009-02       Impact factor: 7.124

4.  Examining the effects of a targeted noise reduction program in a neonatal intensive care unit.

Authors:  D Wang; C Aubertin; N Barrowman; K Moreau; S Dunn; J Harrold
Journal:  Arch Dis Child Fetal Neonatal Ed       Date:  2013-12-19       Impact factor: 5.747

5.  Noise: a hazard for the fetus and newborn. American Academy of Pediatrics. Committee on Environmental Health.

Authors: 
Journal:  Pediatrics       Date:  1997-10       Impact factor: 7.124

6.  Questionable sound exposure outside of the womb: frequency analysis of environmental noise in the neonatal intensive care unit.

Authors:  Amir Lahav
Journal:  Acta Paediatr       Date:  2014-10-27       Impact factor: 2.299

7.  The noise level in a childrens hospital and the wake-up threshold in infants.

Authors:  R Gädeke; B Döring; F Keller; A Vogel
Journal:  Acta Paediatr Scand       Date:  1969-03

8.  Noise and hypoxemia in the intensive care nursery.

Authors:  J G Long; J F Lucey; A G Philip
Journal:  Pediatrics       Date:  1980-01       Impact factor: 7.124

9.  Auditory arousal in preterm infants.

Authors:  S E Gerber; C G Lima; K L Copriviza
Journal:  Scand Audiol Suppl       Date:  1983

10.  Intraoperative Noise Increases Perceived Task Load and Fatigue in Anesthesiology Residents: A Simulation-Based Study.

Authors:  Richard R McNeer; Christopher L Bennett; Roman Dudaryk
Journal:  Anesth Analg       Date:  2016-02       Impact factor: 5.108

View more
  5 in total

Review 1.  What's all that noise-Improving the hospital soundscape.

Authors:  Anthony J Oleksy; Joseph J Schlesinger
Journal:  J Clin Monit Comput       Date:  2018-11-02       Impact factor: 2.502

2.  Effect of a light-darkness cycle on the body weight gain of preterm infants admitted to the neonatal intensive care unit.

Authors:  Manuel Sánchez-Sánchez; Teodoro L García; Donají Heredia; Isaac Reséndiz; Lorena Cruz; Jacqueline Santiago; Adelina Rojas-Granados; Laura Ubaldo-Reyes; Laura Pérez-Campos-Mayoral; Eduardo Pérez-Campos; Gervacio S Vásquez; Juan M Moguel; Romeo Zarate; Oscar García; Luisa Sánchez; Fernando Torres; Alberto Paz; Jesús Elizarraras-Rivas; María T Hernández-Huerta; Manuel Angeles-Castellanos
Journal:  Sci Rep       Date:  2022-10-20       Impact factor: 4.996

3.  Assessment of Noise Exposure and Its Characteristics in the Intensive Care Unit of a Tertiary Hospital.

Authors:  Seungho Jung; Jeongmin Kim; Jiho Lee; Chooljae Rhee; Sungwon Na; Jin-Ha Yoon
Journal:  Int J Environ Res Public Health       Date:  2020-06-29       Impact factor: 3.390

4.  Quality improvement initiative for reduction of false alarms from multiparameter monitors in neonatal intensive care unit.

Authors:  Tanushree Sahoo; Meena Joshi; Shamnad Madathil; Ankit Verma; Mari Jeeva Sankar; Anu Thukral
Journal:  J Educ Health Promot       Date:  2019-10-24

5.  Effects of hydrotherapy and tactile-kinesthetic stimulation on weight gain of preterm infants admitted in the Neonatal Intensive Care Unit.

Authors:  Franciane R Dos Anjos; Adriane M Nakato; Paula Karina Hembecker; Percy Nohama; Ana Lúcia F Sarquis
Journal:  J Pediatr (Rio J)       Date:  2021-06-25       Impact factor: 2.990

  5 in total