Literature DB >> 19375997

Influence of design and bearing material on polyethylene wear particle generation in total knee replacement.

S Utzschneider1, A Paulus, J-C Datz, C Schroeder, B Sievers, B Wegener, V Jansson.   

Abstract

Periprosthetic osteolysis is one of the main reasons for revision of arthroplasty. The osteolytic reaction is influenced by the dose, size and shape of the wear particles. For arthroplasty, a low number and biologically less active particles are required. This is the first study which analyzes the impact of different knee designs, combined with crosslinked polyethylenes (sequentially irradiated and annealed as well as remelted techniques), on the amount, size and shape of particles. Overall, six material combinations, four of them with crosslinked polyethylene (XPE) and two of them with ultra-high molecular weight polyethylene (UHMWPE) inserts, including fixed and mobile bearings, were tested in a knee joint simulator. After isolation nearly 100,000 particles were analyzed in size, shape and number by scanning electron microscopy and image analysis. For all the designs, the wear was predominantly smooth and granular with few fibrillar particles. The Scorpio design with the X3 insert, the Natural Knee II design with the Durasul insert and the LCS design, also combined with a crosslinked polyethylene insert, generated statistically significant (P<0.05) lower particle numbers. The particle size was independent of the radiation dose. The wear generated by the LCS knee design (XPE and UHMWPE) had a higher percentage fraction of particles >1microm in size (equivalent circle diameter). The NexGen design, tested with the Prolong insert, showed a high number of particles in the biologically active size range compared with the other crosslinked designs, which could be a predictor for higher biological reactivity.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19375997     DOI: 10.1016/j.actbio.2009.03.016

Source DB:  PubMed          Journal:  Acta Biomater        ISSN: 1742-7061            Impact factor:   8.947


  13 in total

Review 1.  Polyethylene and metal wear particles: characteristics and biological effects.

Authors:  Isabelle Catelas; Markus A Wimmer; Sandra Utzschneider
Journal:  Semin Immunopathol       Date:  2011-01-26       Impact factor: 9.623

2.  Characteristics of highly cross-linked polyethylene wear debris in vivo.

Authors:  Ryan M Baxter; Daniel W MacDonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Biomed Mater Res B Appl Biomater       Date:  2013-02-22       Impact factor: 3.368

3.  Biological activity and migration of wear particles in the knee joint: an in vivo comparison of six different polyethylene materials.

Authors:  S Utzschneider; V Lorber; M Dedic; A C Paulus; C Schröder; O Gottschalk; M Schmitt-Sody; V Jansson
Journal:  J Mater Sci Mater Med       Date:  2014-02-22       Impact factor: 3.896

4.  [Principles of tribological analysis of endoprostheses].

Authors:  J P Kretzer; C Zietz; C Schröder; J Reinders; L Middelborg; A Paulus; R Sonntag; R Bader; S Utzschneider
Journal:  Orthopade       Date:  2012-10       Impact factor: 1.087

Review 5.  Osteolysis around total knee arthroplasty: a review of pathogenetic mechanisms.

Authors:  J Gallo; S B Goodman; Y T Konttinen; M A Wimmer; M Holinka
Journal:  Acta Biomater       Date:  2013-05-10       Impact factor: 8.947

Review 6.  [Possibilities and limits of modern polyethylenes. With respect to the application profile].

Authors:  S Utzschneider; A C Paulus; C Schröder; V Jansson
Journal:  Orthopade       Date:  2014-06       Impact factor: 1.087

7.  Severe impingement of lumbar disc replacements increases the functional biological activity of polyethylene wear debris.

Authors:  Ryan M Baxter; Daniel W Macdonald; Steven M Kurtz; Marla J Steinbeck
Journal:  J Bone Joint Surg Am       Date:  2013-06-05       Impact factor: 5.284

8.  Wear testing of moderate activities of daily living using in vivo measured knee joint loading.

Authors:  Jörn Reinders; Robert Sonntag; Leo Vot; Christian Gibney; Moritz Nowack; Jan Philippe Kretzer
Journal:  PLoS One       Date:  2015-03-26       Impact factor: 3.240

9.  Wear behavior of an unstable knee: stabilization via implant design?

Authors:  Jörn Reinders; Robert Sonntag; Jan Philippe Kretzer
Journal:  Biomed Res Int       Date:  2014-09-09       Impact factor: 3.411

10.  PMMA third-body wear after unicondylar knee arthroplasty decuples the UHMWPE wear particle generation in vitro.

Authors:  Alexander Christoph Paulus; Manja Franke; Michael Kraxenberger; Christian Schröder; Volkmar Jansson; Sandra Utzschneider
Journal:  Biomed Res Int       Date:  2015-03-19       Impact factor: 3.411

View more