Literature DB >> 19369147

Estimation of respiratory rate from photoplethysmogram data using time-frequency spectral estimation.

Ki H Chon1, Shishir Dash, Kihwan Ju.   

Abstract

We present a new method that uses the pulse oximeter signal to estimate the respiratory rate. The method uses a recently developed time-frequency spectral estimation method, variable-frequency complex demodulation (VFCDM), to identify frequency modulation (FM) of the photoplethysmogram waveform. This FM has a measurable periodicity, which provides an estimate of the respiration period. We compared the performance of VFCDM to the continuous wavelet transform (CWT) and autoregressive (AR) model approaches. The CWT method also utilizes the respiratory sinus arrhythmia effect as represented by either FM or AM to estimate respiratory rates. Both CWT and AR model methods have been previously shown to provide reasonably good estimates of breathing rates that are in the normal range (12-26 breaths/min). However, to our knowledge, breathing rates higher than 26 breaths/min and the real-time performance of these algorithms are yet to be tested. Our analysis based on 15 healthy subjects reveals that the VFCDM method provides the best results in terms of accuracy (smaller median error), consistency (smaller interquartile range of the median value), and computational efficiency (less than 0.3 s on 1 min of data using a MATLAB implementation) to extract breathing rates that varied from 12-36 breaths/min.

Entities:  

Mesh:

Year:  2009        PMID: 19369147     DOI: 10.1109/TBME.2009.2019766

Source DB:  PubMed          Journal:  IEEE Trans Biomed Eng        ISSN: 0018-9294            Impact factor:   4.538


  42 in total

1.  Estimation of respiration rate from three-dimensional acceleration data based on body sensor network.

Authors:  Guan-Zheng Liu; Yan-Wei Guo; Qing-Song Zhu; Bang-Yu Huang; Lei Wang
Journal:  Telemed J E Health       Date:  2011-11       Impact factor: 3.536

2.  Robust respiration detection from remote photoplethysmography.

Authors:  Mark van Gastel; Sander Stuijk; Gerard de Haan
Journal:  Biomed Opt Express       Date:  2016-11-03       Impact factor: 3.732

3.  Noncontact spirometry with a webcam.

Authors:  Chenbin Liu; Yuting Yang; Francis Tsow; Dangdang Shao; Nongjian Tao
Journal:  J Biomed Opt       Date:  2017-05-01       Impact factor: 3.170

4.  An optimized method for the estimation of the respiratory rate from electrocardiographic signals: implications for estimating minute ventilation.

Authors:  Eric H Weiss; Omid Sayadi; Priya Ramaswamy; Faisal M Merchant; Naveen Sajja; Lori Foley; Shawna Laferriere; Antonis A Armoundas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2014-05-23       Impact factor: 4.733

5.  VERB: VFCDM-Based Electrocardiogram Reconstruction and Beat Detection Algorithm.

Authors:  Syed Khairul Bashar; Allan J Walkey; David D McManus; Ki H Chon
Journal:  IEEE Access       Date:  2019-01-21       Impact factor: 3.367

6.  Physiological parameter monitoring from optical recordings with a mobile phone.

Authors:  Christopher G Scully; Jinseok Lee; Joseph Meyer; Alexander M Gorbach; Domhnull Granquist-Fraser; Yitzhak Mendelson; Ki H Chon
Journal:  IEEE Trans Biomed Eng       Date:  2011-07-29       Impact factor: 4.538

7.  Developing an algorithm for pulse oximetry derived respiratory rate (RR(oxi)): a healthy volunteer study.

Authors:  Paul S Addison; James N Watson; Michael L Mestek; Roger S Mecca
Journal:  J Clin Monit Comput       Date:  2012-01-10       Impact factor: 2.502

8.  Contact and Remote Breathing Rate Monitoring Techniques: A Review.

Authors:  Mohamed Ali; Ali Elsayed; Arnaldo Mendez; Yvon Savaria; Mohamad Sawan
Journal:  IEEE Sens J       Date:  2021-04-12       Impact factor: 4.325

9.  A robust ECG denoising technique using variable frequency complex demodulation.

Authors:  Md-Billal Hossain; Syed Khairul Bashar; Jesus Lazaro; Natasa Reljin; Yeonsik Noh; Ki H Chon
Journal:  Comput Methods Programs Biomed       Date:  2020-11-21       Impact factor: 5.428

10.  Utility of a Smartphone-Based System (cvrPhone) in Estimating Minute Ventilation from Electrocardiographic Signals.

Authors:  Kanchan Kulkarni; Navchetan Awasthi; Jesse D Roberts; Antonis A Armoundas
Journal:  Telemed J E Health       Date:  2021-03-15       Impact factor: 3.536

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.