An optimized method for the estimation of the respiratory rate from electrocardiographic signals: implications for estimating minute ventilation.

Eric H Weiss1, Omid Sayadi2, Priya Ramaswamy3, Faisal M Merchant4, Naveen Sajja2, Lori Foley2, Shawna Laferriere2, Antonis A Armoundas5.   

Abstract

It is well-known that respiratory activity influences electrocardiographic (ECG) morphology. In this article we present a new algorithm for the extraction of respiratory rate from either intracardiac or body surface electrograms. The algorithm optimizes selection of ECG leads for respiratory analysis, as validated in a swine model. The algorithm estimates the respiratory rate from any two ECG leads by finding the power spectral peak of the derived ratio of the estimated root-mean-squared amplitude of the QRS complexes on a beat-by-beat basis across a 32-beat window and automatically selects the lead combination with the highest power spectral signal-to-noise ratio. In 12 mechanically ventilated swine, we collected intracardiac electrograms from catheters in the right ventricle, coronary sinus, left ventricle, and epicardial surface, as well as body surface electrograms, while the ventilation rate was varied between 7 and 13 breaths/min at tidal volumes of 500 and 750 ml. We found excellent agreement between the estimated and true respiratory rate for right ventricular (R(2) = 0.97), coronary sinus (R(2) = 0.96), left ventricular (R(2) = 0.96), and epicardial (R(2) = 0.97) intracardiac leads referenced to surface lead ECGII. When applied to intracardiac right ventricular-coronary sinus bipolar leads, the algorithm exhibited an accuracy of 99.1% (R(2) = 0.97). When applied to 12-lead body surface ECGs collected in 4 swine, the algorithm exhibited an accuracy of 100% (R(2) = 0.93). In conclusion, the proposed algorithm provides an accurate estimation of the respiratory rate using either intracardiac or body surface signals without the need for additional hardware.
Copyright © 2014 the American Physiological Society.

Entities:  

Keywords:  body surface; electrograms; estimation; intracardiac; minute ventilation; respiratory rate

Mesh:

Year:  2014        PMID: 24858847      PMCID: PMC4121650          DOI: 10.1152/ajpheart.00039.2014

Source DB:  PubMed          Journal:  Am J Physiol Heart Circ Physiol        ISSN: 0363-6135            Impact factor:   4.733


  29 in total

1.  Ambulatory monitoring of respiration: inhibitory breathing in the natural environment.

Authors:  D E Anderson; K Coyle; J A Haythornthwaite
Journal:  Psychophysiology       Date:  1992-09       Impact factor: 4.016

2.  Feasibility and validation of telespirometry in general practice: The Italian "Alliance" study.

Authors:  M Bonavia; G Averame; W Canonica; C Cricelli; V Fogliani; C Grassi; A M Moretti; P Ferri; A Rossi; P L Paggiaro
Journal:  Respir Med       Date:  2009-06-04       Impact factor: 3.415

3.  Estimation of respiratory rate from photoplethysmogram data using time-frequency spectral estimation.

Authors:  Ki H Chon; Shishir Dash; Kihwan Ju
Journal:  IEEE Trans Biomed Eng       Date:  2009-04-14       Impact factor: 4.538

4.  An optimized method for estimating the tidal volume from intracardiac or body surface electrocardiographic signals: implications for estimating minute ventilation.

Authors:  Omid Sayadi; Eric H Weiss; Faisal M Merchant; Dheeraj Puppala; Antonis A Armoundas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2014-06-06       Impact factor: 4.733

5.  A novel lead configuration for optimal spatio-temporal detection of intracardiac repolarization alternans.

Authors:  Eric H Weiss; Faisal M Merchant; Andre d'Avila; Lori Foley; Vivek Y Reddy; Jagmeet P Singh; Theofanie Mela; Jeremy N Ruskin; Antonis A Armoundas
Journal:  Circ Arrhythm Electrophysiol       Date:  2011-03-23

6.  Prenatal cigarette smoke exposure attenuates recovery from hypoxemic challenge in preterm infants.

Authors:  Jennifer Schneider; Ian Mitchell; Nalini Singhal; Valerie Kirk; Shabih U Hasan
Journal:  Am J Respir Crit Care Med       Date:  2008-06-19       Impact factor: 21.405

7.  ECG-based wireless home infant apnoea monitor.

Authors:  L Fraiwan; O Al-Bataineh; J Matouq; S Haddad; M Bani-Amer
Journal:  J Med Eng Technol       Date:  2009

8.  An improved algorithm for respiration signal extraction from electrocardiogram measured by conductive textile electrodes using instantaneous frequency estimation.

Authors:  Sung-Bin Park; Yeon-Sik Noh; Sung-Jun Park; Hyoung-Ro Yoon
Journal:  Med Biol Eng Comput       Date:  2008-01-22       Impact factor: 2.602

9.  Long-term ventilatory adaptation and ventilatory response to hypoxia in plateau pika (Ochotona curzoniae): role of nNOS and dopamine.

Authors:  Aurélien Pichon; Bai Zhenzhong; Fabrice Favret; Guoen Jin; Han Shufeng; Dominique Marchant; Jean-Paul Richalet; Ri-Li Ge
Journal:  Am J Physiol Regul Integr Comp Physiol       Date:  2009-07-29       Impact factor: 3.619

10.  Positive end-expiratory pressure enhances development of a functional residual capacity in preterm rabbits ventilated from birth.

Authors:  Melissa L Siew; Arjan B Te Pas; Megan J Wallace; Marcus J Kitchen; Robert A Lewis; Andreas Fouras; Colin J Morley; Peter G Davis; Naoto Yagi; Kentaro Uesugi; Stuart B Hooper
Journal:  J Appl Physiol (1985)       Date:  2009-03-26
View more
  7 in total

1.  ECG-derived Cheyne-Stokes respiration and periodic breathing in healthy and hospitalized populations.

Authors:  Adelita Tinoco; Barbara J Drew; Xiao Hu; David Mortara; Bruce A Cooper; Michele M Pelter
Journal:  Ann Noninvasive Electrocardiol       Date:  2017-06-15       Impact factor: 1.468

2.  An optimized method for estimating the tidal volume from intracardiac or body surface electrocardiographic signals: implications for estimating minute ventilation.

Authors:  Omid Sayadi; Eric H Weiss; Faisal M Merchant; Dheeraj Puppala; Antonis A Armoundas
Journal:  Am J Physiol Heart Circ Physiol       Date:  2014-06-06       Impact factor: 4.733

3.  A Novel Point-of-Care Smartphone Based System for Monitoring the Cardiac and Respiratory Systems.

Authors:  Kwanghyun Sohn; Faisal M Merchant; Omid Sayadi; Dheeraj Puppala; Rajiv Doddamani; Ashish Sahani; Jagmeet P Singh; E Kevin Heist; Eric M Isselbacher; Antonis A Armoundas
Journal:  Sci Rep       Date:  2017-03-22       Impact factor: 4.379

4.  Utility of a smartphone based system (cvrphone) to accurately determine apneic events from electrocardiographic signals.

Authors:  Kwanghyun Sohn; Faisal M Merchant; Shady Abohashem; Kanchan Kulkarni; Jagmeet P Singh; E Kevin Heist; Chris Owen; Jesse D Roberts; Eric M Isselbacher; Furrukh Sana; Antonis A Armoundas
Journal:  PLoS One       Date:  2019-06-17       Impact factor: 3.240

Review 5.  Breathing Rate Estimation From the Electrocardiogram and Photoplethysmogram: A Review.

Authors:  Peter H Charlton; Drew A Birrenkott; Timothy Bonnici; Marco A F Pimentel; Alistair E W Johnson; Jordi Alastruey; Lionel Tarassenko; Peter J Watkinson; Richard Beale; David A Clifton
Journal:  IEEE Rev Biomed Eng       Date:  2017-10-24

6.  Utility of a Smartphone-Based System (cvrPhone) in Estimating Minute Ventilation from Electrocardiographic Signals.

Authors:  Kanchan Kulkarni; Navchetan Awasthi; Jesse D Roberts; Antonis A Armoundas
Journal:  Telemed J E Health       Date:  2021-03-15       Impact factor: 3.536

7.  Design Implementation and Evaluation of a Mobile Continuous Blood Oxygen Saturation Monitoring System.

Authors:  Qingxue Zhang; David Arney; Julian M Goldman; Eric M Isselbacher; Antonis A Armoundas
Journal:  Sensors (Basel)       Date:  2020-11-18       Impact factor: 3.576

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.