Literature DB >> 19361735

Computed tomographic analysis of tooth-bearing alveolar bone for orthodontic miniscrew placement.

Kee-Joon Lee1, Euk Joo, Kee-Deog Kim, Jong-Suk Lee, Young-Chel Park, Hyung-Seog Yu.   

Abstract

INTRODUCTION: When monocortical orthodontic miniscrews are placed in interdental alveolar bone, the safe position of the miniscrew tip should be ensured. This study was designed to quantify the periradicular space in the tooth-bearing area to provide practical guidelines for miniscrew placement.
METHODS: Computerized tomographs of 30 maxillae and mandibles were taken from nonorthodontic adults with normal occlusion. Both mesiodistal interradicular distance and bone thickness over the narrowest interradicular space (safety depth) were measured at 2, 4, 6, and 8 mm from the cementoenamel junction.
RESULTS: Mesiodistal space greater than 3 mm was available at the 8-mm level in the maxillary anterior region, between the premolars, and between the second premolar and the first molar at 4 mm. In the mandible, sufficient mesiodistal space was found between the premolars, between the molars, and between the second premolar and the first molar at the 4-mm level. Safety depth greater than 4 mm was found in the maxillary and mandibular intermolar regions, and between the second premolar and the first molar in both arches.
CONCLUSIONS: Subapical placement is advocated in the anterior segment. Premolar areas appear reliable in both arches. Angulated placement in the intermolar area is suggested to use the sufficient safety depth in this area.

Entities:  

Mesh:

Substances:

Year:  2009        PMID: 19361735     DOI: 10.1016/j.ajodo.2007.05.019

Source DB:  PubMed          Journal:  Am J Orthod Dentofacial Orthop        ISSN: 0889-5406            Impact factor:   2.650


  27 in total

1.  Tomographic analysis of the interalveolar space and thickness of the vestibular cortical bone in the parasymphyseal region of adult human mandibles.

Authors:  Atson Carlos de Souza Fernandes; Sandra de Quadros Uzeda-Gonzalez; Ricardo Luiz Smith; Luis Garcia Alonso; Fabio Mota Gonzalez; Marcos Vinicius Santos
Journal:  Surg Radiol Anat       Date:  2010-04-10       Impact factor: 1.246

2.  Measurement of cortical bone thickness in adults by cone-beam computerized tomography for orthodontic miniscrews placement.

Authors:  Hong Zhao; Xiao-Ming Gu; Hong-Chen Liu; Zhao-Wu Wang; Chun-Lei Xun
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2013-04-17

3.  Buccal cortical bone thickness at miniscrew placement sites in patients with different vertical skeletal patterns.

Authors:  Ilknur Veli; Tancan Uysal; Asli Baysal; Irfan Karadede
Journal:  J Orofac Orthop       Date:  2014-10-26       Impact factor: 1.938

4.  Evaluation of Interdental Spaces of the Mandibular Posterior Area for Orthodontic Mini-Implants with Cone-Beam Computed Tomography.

Authors:  Seyed Hossein Moslemzadeh; Aydin Sohrabi; Ali Rafighi; Yusef Kananizadeh; Amin Nourizadeh
Journal:  J Clin Diagn Res       Date:  2017-04-01

5.  "Safe zones" for miniscrew implant placement in different dentoskeletal patterns.

Authors:  Pajongjit Chaimanee; Boonsiva Suzuki; Eduardo Yugo Suzuki
Journal:  Angle Orthod       Date:  2011-01-24       Impact factor: 2.079

6.  Accuracy of orthodontic miniscrew implantation guided by stereolithographic surgical stent based on cone-beam CT-derived 3D images.

Authors:  Lingling Qiu; Naoto Haruyama; Shoichi Suzuki; Daisuke Yamada; Naoto Obayashi; Toru Kurabayashi; Keiji Moriyama
Journal:  Angle Orthod       Date:  2011-08-17       Impact factor: 2.079

7.  Absolute anchorage with universal T-loop mechanics for severe deepbite and maxillary anterior protrusion and its 10-year stability.

Authors:  Yoon Jeong Choi; Chooryung Judi Chung; Kwangchul Choy; Kyung-Ho Kim
Journal:  Angle Orthod       Date:  2010-07       Impact factor: 2.079

8.  Biomechanical characteristics and reinsertion guidelines for retrieved orthodontic miniscrews.

Authors:  Chooryung J Chung; Kil-Young Jung; Yoon Jeong Choi; Kyung-Ho Kim
Journal:  Angle Orthod       Date:  2014-03-03       Impact factor: 2.079

9.  Cone-Beam Computed Tomographic Assessment of Bone Thickness in the Mandibular Anterior Region for Application of Orthodontic Mini-Screws.

Authors:  Majid Shalchi; Zahra Dalili Kajan; Mohammad Shabani; Negar Khosravifard; Samar Khabbaz; Farnoosh Khaksari
Journal:  Turk J Orthod       Date:  2021-06

10.  An in vitro study of factors affecting the primary stability of orthodontic mini-implants.

Authors:  Lindsy Holm; Susan J Cunningham; Aviva Petrie; Richard R J Cousley
Journal:  Angle Orthod       Date:  2012-05-07       Impact factor: 2.079

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.