Literature DB >> 1936049

Technetium-99m teboroxime scintigraphy. Clinical experience in patients referred for myocardial perfusion evaluation.

L Bontemps1, X Geronicola-Trapali, Y Sayegh, O Delmas, R Itti, X André-Fouët.   

Abstract

In order to evaluate the clinical value of a new myocardial perfusion tracer, a series of 30 patients (25 male, 5 female, mean age 56 years) referred for thallium 201 stress/redistribution scintigraphy has been studied using stress/rest (n = 7) or rest/stress (n = 23) protocols with technetium 99m teboroxime (Cardiotec SQUIBB). In all cases coronary artery disease was known or highly probable, with a history of myocardial infarction in 18 cases. Medical treatment was not discontinued at the time of stress testing, and coronary angiography was available in 27 patients. Exercise tests for both tracers were carried out on a bicycle ergometer during the same day, and the levels of exercise achieved for the 201Tl study were very similar to those achieved for 99mTc-teboroxime. Studies performed in three planar projections were evaluated using a model with four territories: septal and anterior assumed to correspond to the left anterior descending artery, lateral and latero-posterior (left circonflex), inferior and posterior (right coronary artery) and apex. Classification of results was: normal, ischaemic, infarcted and infarcted with ischaemia. On comparison with the 201Tl results, agreement was found in 86% (37/43) of normal regions and in 82% (63/77) of abnormal regions. Relative to documented coronary artery lesions (27 patients), sensitivity and specificity of 201Tl and 99mTc-teboroxime for exact correspondence between arteries and territories were respectively: 201Tl: sensitivity 64%, specificity 60%; 99mTc-teboroxime: sensitivity 62%, specificity 77%.(ABSTRACT TRUNCATED AT 250 WORDS)

Entities:  

Mesh:

Substances:

Year:  1991        PMID: 1936049     DOI: 10.1007/bf00956714

Source DB:  PubMed          Journal:  Eur J Nucl Med        ISSN: 0340-6997


  9 in total

1.  Myocardial kinetics of technetium-99m-hexakis-2-methoxy-2-methylpropyl-isonitrile.

Authors:  R D Okada; D Glover; T Gaffney; S Williams
Journal:  Circulation       Date:  1988-02       Impact factor: 29.690

2.  Hexakis (2-methoxy isobutylisonitrile) technetium-99m and thallium-201 chloride: uptake and release in cultured myocardial cells.

Authors:  J C Maublant; P Gachon; N Moins
Journal:  J Nucl Med       Date:  1988-01       Impact factor: 10.057

3.  Same day injections of Tc-99m methoxy isobutyl isonitrile (hexamibi) for myocardial tomographic imaging: comparison between rest-stress and stress-rest injection sequences.

Authors:  R Taillefer; A Gagnon; L Laflamme; J Grégoire; J Léveillé; D C Phaneuf
Journal:  Eur J Nucl Med       Date:  1989

Review 4.  Clinical experience with technetium-99m teboroxime, a neutral, lipophilic myocardial perfusion imaging agent.

Authors:  L L Johnson; D W Seldin
Journal:  Am J Cardiol       Date:  1990-10-16       Impact factor: 2.778

5.  Increased lung uptake of thallium-201 during exercise myocardial imaging: clinical, hemodynamic and angiographic implications in patients with coronary artery disease.

Authors:  C A Boucher; L M Zir; G A Beller; R D Okada; K A McKusick; H W Strauss; G M Pohost
Journal:  Am J Cardiol       Date:  1980-08       Impact factor: 2.778

6.  Myocardial perfusion imaging with technetium-99m SQ30217: comparison with thallium-201 and coronary anatomy.

Authors:  D W Seldin; L L Johnson; D K Blood; M J Muschel; K F Smith; R M Wall; P J Cannon
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

7.  Myocardial perfusion imaging with a new radiotracer, technetium-99m-hexamibi (methoxy isobutyl isonitrile): comparison with thallium-201 imaging.

Authors:  R Taillefer; G Dupras; V Sporn; P Rigo; J Leveille; P Boucher; N Perez-Balino; L L Camin; K A McKusick
Journal:  Clin Nucl Med       Date:  1989-02       Impact factor: 7.794

8.  Cationic Tc-99m complexes as potential myocardial imaging agents.

Authors:  E Deutsch; K A Glavan; V J Sodd; H Nishiyama; D L Ferguson; S J Lukes
Journal:  J Nucl Med       Date:  1981-10       Impact factor: 10.057

9.  Technetium-99m hexakis 2-methoxyisobutyl isonitrile: human biodistribution, dosimetry, safety, and preliminary comparison to thallium-201 for myocardial perfusion imaging.

Authors:  F J Wackers; D S Berman; J Maddahi; D D Watson; G A Beller; H W Strauss; C A Boucher; M Picard; B L Holman; R Fridrich
Journal:  J Nucl Med       Date:  1989-03       Impact factor: 10.057

  9 in total
  8 in total

1.  4D maximum a posteriori reconstruction in dynamic SPECT using a compartmental model-based prior.

Authors:  D J Kadrmas; G T Gullberg
Journal:  Phys Med Biol       Date:  2001-05       Impact factor: 3.609

2.  Comparison of thallium-201 and technetium-99m teboroxime myocardial single photon emission tomography with coronary arteriography.

Authors:  M Oshima; M Ishihara; H Sano; S Ohsugi; M Ohno; S Hayase; M Yokota; H Akanabe; K Ito; S Sakuma
Journal:  Eur J Nucl Med       Date:  1992

3.  Myocardial blood flow quantification with SPECT and conventional tracers: a critical appraisal.

Authors:  Stephan G Nekolla; Christoph Rischpler; Kenichi Nakajima
Journal:  J Nucl Cardiol       Date:  2014-10-04       Impact factor: 5.952

4.  Removal of liver activity contamination in teboroxime dynamic cardiac SPECT imaging with the use of factor analysis.

Authors:  Arkadiusz Sitek; Edward V R Di Bella; Grant T Gullberg; Ronald H Huesman
Journal:  J Nucl Cardiol       Date:  2002 Mar-Apr       Impact factor: 5.952

5.  Compartmental modeling of technetium-99m-labeled teboroxime with dynamic single-photon emission computed tomography: comparison with static thallium-201 in a canine model.

Authors:  E V Di Bella; S G Ross; D J Kadrmas; H S Khare; P E Christian; S McJames; A G Gullberg
Journal:  Invest Radiol       Date:  2001-03       Impact factor: 6.016

6.  Myocardial technetium 99m-labeled teboroxime clearance derived from canine scans differentiates severity of stenosis after dipyridamole.

Authors:  G Johnson; D K Glover; C B Hebert; R D Okada
Journal:  J Nucl Cardiol       Date:  1994 Jul-Aug       Impact factor: 5.952

7.  The Canadian exercise technetium 99m-labeled teboroxime single-photon emission computed tomographic study. Canadian Exercise Teboroxime SPECT Study Investigators.

Authors:  R J Burns; S Iles; A Y Fung; L M Wright; L Daigneault
Journal:  J Nucl Cardiol       Date:  1995 Mar-Apr       Impact factor: 5.952

8.  Diagnostic utility of tomographic myocardial perfusion imaging with technetium 99m furifosmin (Q12) compared with thallium 201: results of a phase III multicenter trial.

Authors:  R C Hendel; M S Verani; D D Miller; F J Wackers; M McMahon; M D Cerqueira; E H Botvinick; L Kvols; M C Gerson
Journal:  J Nucl Cardiol       Date:  1996 Jul-Aug       Impact factor: 5.952

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.