Literature DB >> 19353666

B1(+) interferometry for the calibration of RF transmitter arrays.

David O Brunner1, Klaas P Pruessmann.   

Abstract

Multiple-channel RF transmission holds great promise for MRI, especially for human applications at high fields. For calibration it requires mapping the effective RF magnetic fields, B(1) (+), of the transmitter array. This is challenging to do accurately and fast due to the large dynamic range of B(1) (+) and tight SAR constraints. In the present work, this problem is revisited and solved by a novel mapping approach relying on an interference principle. The B(1) (+) fields of individual transmitter elements are measured indirectly by observing their interference with a SAR-efficient baseline RF field. In this fashion even small RF fields can be observed in the B(1) (+) -sensitive large-flip-angle regime. Based on a set of such experiments B(1) (+) maps of the individual transmitter channels are obtained by solving a linear inverse problem. Confounding relaxation and off-resonance effects are addressed by an extended signal model and nonlinear fitting. Using the novel approach, 2D mapping of an 8-channel transmitter array was accomplished in less than a minute. For validation it is demonstrated that mapping results do not vary with T(1) or parameters of the mapping sequence. In RF shimming experiments it is shown that the measured B(1) (+) maps accurately reflect the linearity of RF superposition.

Entities:  

Mesh:

Year:  2009        PMID: 19353666     DOI: 10.1002/mrm.21893

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  20 in total

1.  Regularized estimation of magnitude and phase of multi-coil b1 field via Bloch-Siegert B1 mapping and coil combination optimizations.

Authors:  Feng Zhao; Jeffrey A Fessler; Steven M Wright; Douglas C Noll
Journal:  IEEE Trans Med Imaging       Date:  2014-06-09       Impact factor: 10.048

2.  Correction of parallel transmission using concurrent RF and gradient field monitoring.

Authors:  Mustafa Çavuşoğlu; Benjamin Emanuel Dietrich; David Otto Brunner; Markus Weiger; Klaas Paul Pruessmann
Journal:  MAGMA       Date:  2017-04-25       Impact factor: 2.310

3.  Array-compressed parallel transmit pulse design.

Authors:  Zhipeng Cao; Xinqiang Yan; William A Grissom
Journal:  Magn Reson Med       Date:  2015-10-28       Impact factor: 4.668

4.  An in vivo comparison of the DREAM sequence with current RF shim technology.

Authors:  Kay Nehrke; Alois M Sprinkart; Peter Börnert
Journal:  MAGMA       Date:  2014-08-10       Impact factor: 2.310

5.  Two-dimensional sixteen channel transmit/receive coil array for cardiac MRI at 7.0 T: design, evaluation, and application.

Authors:  Christof Thalhammer; Wolfgang Renz; Lukas Winter; Fabian Hezel; Jan Rieger; Harald Pfeiffer; Andreas Graessl; Frank Seifert; Werner Hoffmann; Florian von Knobelsdorff-Brenkenhoff; Valeriy Tkachenko; Jeanette Schulz-Menger; Peter Kellman; Thoralf Niendorf
Journal:  J Magn Reson Imaging       Date:  2012-06-15       Impact factor: 4.813

6.  System and SAR characterization in parallel RF transmission.

Authors:  Yudong Zhu; Leeor Alon; Cem M Deniz; Ryan Brown; Daniel K Sodickson
Journal:  Magn Reson Med       Date:  2011-12-02       Impact factor: 4.668

7.  Gradient-based magnetic resonance electrical properties imaging of brain tissues.

Authors:  Sebastian Schmitter; Pierre-Francois Van de Moortele
Journal:  Conf Proc IEEE Eng Med Biol Soc       Date:  2014

8.  TROMBONE: T1-relaxation-oblivious mapping of transmit radio-frequency field (B1) for MRI at high magnetic fields.

Authors:  Roman Fleysher; Lazar Fleysher; Matilde Inglese; Daniel Sodickson
Journal:  Magn Reson Med       Date:  2011-03-09       Impact factor: 4.668

Review 9.  Magnetic-resonance-based electrical properties tomography: a review.

Authors:  Xiaotong Zhang; Jiaen Liu; Bin He
Journal:  IEEE Rev Biomed Eng       Date:  2014

10.  A method to localize RF B₁ field in high-field magnetic resonance imaging systems.

Authors:  Hyoungsuk Yoo; Anand Gopinath; J Thomas Vaughan
Journal:  IEEE Trans Biomed Eng       Date:  2012-08-23       Impact factor: 4.538

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.