Literature DB >> 19336295

Impact on reader performance for lesion-detection/ localization tasks of anatomical priors in SPECT reconstruction.

Andre Lehovich1, Philippe P Bruyant, Howard S Gifford, Peter B Schneider, Shayne Squires, Robert Licho, Gene Gindi, Michael A King.   

Abstract

With increasing availability of multimodality imaging systems, high-resolution anatomical images can be used to guide the reconstruction of emission tomography studies. By measuring reader performance on a lesion detection task, this study investigates the improvement in image-quality due to use of prior anatomical knowledge, for example organ or lesion boundaries, during SPECT reconstruction. Simulated (67)Ga -citrate source and attenuation distributions were created from the mathematical cardiac-torso (MCAT) anthropomorphic digital phantom. The SIMIND Monte Carlo software was then used to generate SPECT projection data. The data were reconstructed using the De Pierro maximum a posteriori (MAP) algorithm and the rescaled-block-iterative (RBI) algorithm for comparison. We compared several degrees of prior knowledge about the anatomy: no knowledge about the anatomy; knowledge of organ boundaries; knowledge of organ and lesion boundaries; and knowledge of organ, lesion, and pseudo-lesion (non-emission uptake altering) boundaries. The MAP reconstructions used quadratic smoothing within anatomical regions, but not across any provided region boundaries. The reconstructed images were read by human observers searching for lesions in a localization receiver operating characteristic (LROC) study of the relative detection/localization accuracies of the reconstruction algorithms. Area under the LROC curve was computed for each algorithm as the comparison metric. We also had humans read images reconstructed using different prior strengths to determine the optimal trade-off between data consistency and the anatomical prior. Finally by mixing together images reconstructed with and without the prior, we tested to see if having an anatomical prior only some of the time changes the observer's detection/localization accuracy on lesions where no boundary prior is available. We found that anatomical priors including organ and lesion boundaries improve observer performance on the lesion detection/localization task. Use of just organ boundaries did not provide a statistically significant improvement in performance however. We also found that optimal prior strength depends on the level of anatomical knowledge, with a broad plateau in which observer performance is near optimal. We found no evidence that having anatomical priors use lesion boundaries only when available changes the observer's performance when they are not available. We conclude that use of anatomical priors with organ and lesion boundaries improves reader performance on a lesion-detection/localization task, and that pseudo-lesion boundaries do not hurt reader performance. However, we did not find evidence that a prior using only organ boundaries helps observer performance. Therefore we suggest prior strength should be tuned to the organ-only case, since a prior will likely not be available for all lesions.

Entities:  

Mesh:

Year:  2009        PMID: 19336295      PMCID: PMC2829316          DOI: 10.1109/TMI.2009.2017741

Source DB:  PubMed          Journal:  IEEE Trans Med Imaging        ISSN: 0278-0062            Impact factor:   10.048


  26 in total

1.  Clinically feasible reconstruction of 3D whole-body PET/CT data using blurred anatomical labels.

Authors:  Claude Comtat; Paul E Kinahan; Jeffrey A Fessler; Thomas Beyer; David W Townsend; Michel Defrise; Christian Michel
Journal:  Phys Med Biol       Date:  2002-01-07       Impact factor: 3.609

2.  Magnetic resonance imaging-guided attenuation and scatter corrections in three-dimensional brain positron emission tomography.

Authors:  Habib Zaidi; Marie-Louise Montandon; Daniel O Slosman
Journal:  Med Phys       Date:  2003-05       Impact factor: 4.071

3.  Description of a prototype emission-transmission computed tomography imaging system.

Authors:  T F Lang; B H Hasegawa; S C Liew; J K Brown; S C Blankespoor; S M Reilly; E L Gingold; C E Cann
Journal:  J Nucl Med       Date:  1992-10       Impact factor: 10.057

4.  Evaluation of video gray-scale display.

Authors:  R D Nawfel; K H Chan; D J Wagenaar; P F Judy
Journal:  Med Phys       Date:  1992 May-Jun       Impact factor: 4.071

5.  67Ga-SPECT/CT with a hybrid system in the clinical management of lymphoma.

Authors:  Barbara Palumbo; Silvio Sivolella; Isabella Palumbo; Anna Marina Liberati; Renato Palumbo
Journal:  Eur J Nucl Med Mol Imaging       Date:  2005-05-14       Impact factor: 9.236

6.  Simultaneous acquisition of multislice PET and MR images: initial results with a MR-compatible PET scanner.

Authors:  Ciprian Catana; Yibao Wu; Martin S Judenhofer; Jinyi Qi; Bernd J Pichler; Simon R Cherry
Journal:  J Nucl Med       Date:  2006-12       Impact factor: 10.057

7.  A channelized Hotelling observer study of lesion detection in SPECT MAP reconstruction using anatomical priors.

Authors:  S Kulkarni; P Khurd; I Hsiao; L Zhou; G Gindi
Journal:  Phys Med Biol       Date:  2007-05-23       Impact factor: 3.609

8.  A modified expectation maximization algorithm for penalized likelihood estimation in emission tomography.

Authors:  A R De Pierro
Journal:  IEEE Trans Med Imaging       Date:  1995       Impact factor: 10.048

9.  Accelerating the EMML algorithm and related iterative algorithms by rescaled block-iterative methods.

Authors:  C L Byrne
Journal:  IEEE Trans Image Process       Date:  1998       Impact factor: 10.856

10.  Assessment of scatter compensation strategies for (67)Ga SPECT using numerical observers and human LROC studies.

Authors:  Troy H Farncombe; Howard C Gifford; Manoj V Narayanan; P Hendrik Pretorius; Eric C Frey; Michael A King
Journal:  J Nucl Med       Date:  2004-05       Impact factor: 10.057

View more
  5 in total

1.  A nonparametric procedure for comparing the areas under correlated LROC curves.

Authors:  Adam Wunderlich; Frédéric Noo
Journal:  IEEE Trans Med Imaging       Date:  2012-06-18       Impact factor: 10.048

2.  Improved quantification in multiple-pinhole SPECT by anatomy-based reconstruction using microCT information.

Authors:  Christian Vanhove; Michel Defrise; Axel Bossuyt; Tony Lahoutte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2010-09-30       Impact factor: 9.236

3.  Numerical Surrogates for Human Observers in Myocardial Motion Evaluation From SPECT Images.

Authors:  Thibault Marin; Mahdi M Kalayeh; Felipe M Parages; Jovan G Brankov
Journal:  IEEE Trans Med Imaging       Date:  2013-08-22       Impact factor: 10.048

Review 4.  Magnetic resonance-guided positron emission tomography image reconstruction.

Authors:  Bing Bai; Quanzheng Li; Richard M Leahy
Journal:  Semin Nucl Med       Date:  2013-01       Impact factor: 4.446

5.  Target localization using scanner-acquired SPECT data.

Authors:  Justin R Roper; James E Bowsher; Joshua M Wilson; Timothy G Turkington; Fang-Fang Yin
Journal:  J Appl Clin Med Phys       Date:  2012-05-10       Impact factor: 2.102

  5 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.