Literature DB >> 1403162

Description of a prototype emission-transmission computed tomography imaging system.

T F Lang1, B H Hasegawa, S C Liew, J K Brown, S C Blankespoor, S M Reilly, E L Gingold, C E Cann.   

Abstract

We have developed a prototype imaging system that can perform simultaneous x-ray transmission CT and SPECT phantom studies. This system employs a 23-element high-purity-germanium detector array. The detector array is coupled to a collimator with septa angled toward the focal spot of an x-ray tube. During image acquisition, the x-ray fan beam and the detector array move synchronously along an arc pivoted at the x-ray source. Multiple projections are obtained by rotating the object, which is mounted at the center of rotation of the system. The detector array and electronics can count up to 10(6) cps/element with sufficient energy-resolution to discriminate between x-rays at 100-120 kVp and gamma rays from 99mTc. We have used this device to acquire x-ray CT and SPECT images of a three-dimensional Hoffman brain phantom. The emission and transmission images may be superimposed in order to localize the emission image on the transmission map.

Entities:  

Keywords:  NASA Discipline Musculoskeletal; Non-NASA Center

Mesh:

Year:  1992        PMID: 1403162

Source DB:  PubMed          Journal:  J Nucl Med        ISSN: 0161-5505            Impact factor:   10.057


  33 in total

1.  Assessment of geometrical distortion and activity distribution after attenuation correction: A SPECT phantom study.

Authors:  Sara Lappi; Simonetta Lazzari; Graziella Sarti; Pierluigi Pieri
Journal:  J Nucl Cardiol       Date:  2002 Sep-Oct       Impact factor: 5.952

2.  Direct Image-Based Attenuation Correction using Conditional Generative Adversarial Network for SPECT Myocardial Perfusion Imaging.

Authors:  Mahsa Torkaman; Jaewon Yang; Luyao Shi; Rui Wang; Edward J Miller; Albert J Sinusas; Chi Liu; Grant T Gullberg; Youngho Seo
Journal:  Proc SPIE Int Soc Opt Eng       Date:  2021-02-15

3.  Development of a cost-effective modular SPECT/CT scanner.

Authors:  Dale L Bailey; Paul J Roach; Elizabeth A Bailey; James Hewlett; Ronnie Keijzers
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-03-20       Impact factor: 9.236

Review 4.  Review of functional/anatomical imaging in oncology.

Authors:  Stephanie N Histed; Maria L Lindenberg; Esther Mena; Baris Turkbey; Peter L Choyke; Karen A Kurdziel
Journal:  Nucl Med Commun       Date:  2012-04       Impact factor: 1.690

5.  Multi-modality imaging on track.

Authors:  Freek Beekman; Brian F Hutton
Journal:  Eur J Nucl Med Mol Imaging       Date:  2007-09       Impact factor: 9.236

6.  Exact emission SPECT reconstruction with truncated transmission data.

Authors:  Gengsheng L Zeng; Grant T Gullberg
Journal:  Phys Med Biol       Date:  2009-05-08       Impact factor: 3.609

Review 7.  Novel detector technology for clinical PET.

Authors:  Roger Lecomte
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-03       Impact factor: 9.236

8.  Will high-resolution/high-sensitivity SPECT ensure that PET is not the only survivor in nuclear medicine during the next decade?

Authors:  Alain Seret
Journal:  Eur J Nucl Med Mol Imaging       Date:  2009-01-14       Impact factor: 9.236

Review 9.  Positron emission tomography-magnetic resonance imaging: technical review.

Authors:  Raymond F Muzic; Frank P DiFilippo
Journal:  Semin Roentgenol       Date:  2014-10-18       Impact factor: 0.800

10.  Optimization-based image reconstruction from sparse-view data in offset-detector CBCT.

Authors:  Junguo Bian; Jiong Wang; Xiao Han; Emil Y Sidky; Lingxiong Shao; Xiaochuan Pan
Journal:  Phys Med Biol       Date:  2012-12-21       Impact factor: 3.609

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.