Literature DB >> 19328276

Retention forces of spherical attachments as a function of implant and matrix angulation in mandibular overdentures: an in vitro study.

Sergio M Ortegón1, Geoffrey A Thompson, John R Agar, Thomas D Taylor, Dimitri Perdikis.   

Abstract

STATEMENT OF PROBLEM: Nonparallel implants, when used to retain overdentures, may present a restorative challenge, particularly when using attachments. Premature wear of the components and loss of retention may be observed, resulting in increased maintenance.
PURPOSE: The purpose of this study was to compare the retentive behavior, over time, of spherical attachments when used in nonparallel and parallel implant scenarios in a cyclic testing mode.
MATERIAL AND METHODS: Thirty sets of 2-implant-supported overdenture models were evaluated: 4.0 x 13-mm implants (Astra-Tech Osseospeed) with 1.5-mm ball abutments (Astra-Tech) were used as the intraoral analog to the implants, and spherical attachments (Preci Clix) were used as the overdenture analog. Five different attachment and implant-abutment complex angulations were evaluated. Angulation was determined by deviation from the vertical reference plane. The groups consisted of the following: Group 0-0, 0-degree implants/0-degree attachments; Group 10-0, 10-degree implants/0-degree attachments; Group 15-0, 15-degree implants/0-degree attachments; Group 10-10, 10-degree implants/10-degree attachments; and Group 15-15, 15-degree implants/15-degree attachments. The specimens were subjected to cyclic loading (3500 cycles). Peak and valley retention loads were recorded at the first pull and then after every 100 cycles; therefore, 36 data points per specimen were recorded. Nonparametric analyses followed by post hoc analyses were conducted to test for differences in median peak load among groups (alpha=.05).
RESULTS: Peak load to dislodgment values for all groups ranged from 11.43 N to 23.56 N. Group 0-0 had the highest median retention value overall, 21.3 N, and Group 15-15 had the lowest median value, 17.3 N. Nonparametric analyses showed significant differences between Groups 0-0 and 15-15 (P=.014); and 10-0 and 15-15 (P=.002).
CONCLUSIONS: Within the limitations of this study, it was observed that there was a decrease in retention in the groups with 30-degree divergent implants and divergent attachments compared to the groups with parallel implants and parallel attachments. In general, retention varied from 11 N to 23 N, and attachment retention stabilized after initial loss in most groups.

Mesh:

Substances:

Year:  2009        PMID: 19328276     DOI: 10.1016/S0022-3913(09)60045-7

Source DB:  PubMed          Journal:  J Prosthet Dent        ISSN: 0022-3913            Impact factor:   3.426


  9 in total

1.  An in vitro investigation into retention strength and fatigue resistance of various designs of tooth/implant supported overdentures.

Authors:  Abdalbseet A Fatalla; Ke Song; Tianfeng Du; Yingguang Cao
Journal:  J Huazhong Univ Sci Technolog Med Sci       Date:  2012-01-27

2.  Stud attachments for the mandibular implant-retained overdentures: Prosthetic complications. A literature review.

Authors:  Elie E Daou
Journal:  Saudi Dent J       Date:  2013-02-06

3.  The influences of implant angulations in one and two directions on the retentive properties of overdenture attachments: an in vitro study.

Authors:  Parsa Atashrazm; Mohammad Hossein Dashti; Leila Zamani Alavijeh; Samira Azarmaeh; Sayena Mahdizadeh
Journal:  J Indian Prosthodont Soc       Date:  2013-04-12

Review 4.  Biomaterial aspects: A key factor in the longevity of implant overdenture attachment systems.

Authors:  Elie E Daou
Journal:  J Int Soc Prev Community Dent       Date:  2015 Jul-Aug

5.  The influence of saliva pH value on the retention and durability of bar-clip attachments.

Authors:  Antonio Sergio Silva; Carlos Aroso; Raul Ustrell; Ana Cristina Braga; Jose Manuel Mendes; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2015-02-17       Impact factor: 1.904

6.  In Vitro Effects of Cyclic Dislodgement on Retentive Properties of Various Titanium-Based Dental Implant Overdentures Attachment System.

Authors:  Tae-Yun Kang; Jee-Hwan Kim; Kwang-Mahn Kim; Jae-Sung Kwon
Journal:  Materials (Basel)       Date:  2019-11-16       Impact factor: 3.623

Review 7.  Evaluation of Retention, Wear, and Maintenance of Attachment Systems for Single- or Two-Implant-Retained Mandibular Overdentures: A Systematic Review.

Authors:  Raphaël Wakam; Aurélie Benoit; Kwamivi Bernardin Mawussi; Caroline Gorin
Journal:  Materials (Basel)       Date:  2022-03-04       Impact factor: 3.623

8.  Effect of abutment angulation in the retention and durability of three overdenture attachment systems: An in vitro study.

Authors:  Carlos Aroso; Antonio Sergio Silva; Raul Ustrell; Jose Manuel Mendes; Ana Cristina Braga; Esther Berastegui; Tomas Escuin
Journal:  J Adv Prosthodont       Date:  2016-02-23       Impact factor: 1.904

9.  Evaluation of two interforaminal implants and implant-assisted removable dentures on stress distribution: an in vitro study.

Authors:  Selda Arat Bilhan; Onur Geckili; Altug Cilingir; Ergun Bozdag; Hakan Bilhan
Journal:  J Korean Assoc Oral Maxillofac Surg       Date:  2019-08-28
  9 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.