| Literature DB >> 19298678 |
Jason R Kelly1, Adam J Rubin, Joseph H Davis, Caroline M Ajo-Franklin, John Cumbers, Michael J Czar, Kim de Mora, Aaron L Glieberman, Dileep D Monie, Drew Endy.
Abstract
BACKGROUND: The engineering of many-component, synthetic biological systems is being made easier by the development of collections of reusable, standard biological parts. However, the complexity of biology makes it difficult to predict the extent to which such efforts will succeed. As a first practical example, the Registry of Standard Biological Parts started at MIT now maintains and distributes thousands of BioBrick standard biological parts. However, BioBrick parts are only standardized in terms of how individual parts are physically assembled into multi-component systems, and most parts remain uncharacterized. Standardized tools, techniques, and units of measurement are needed to facilitate the characterization and reuse of parts by independent researchers across many laboratories.Entities:
Year: 2009 PMID: 19298678 PMCID: PMC2683166 DOI: 10.1186/1754-1611-3-4
Source DB: PubMed Journal: J Biol Eng ISSN: 1754-1611 Impact factor: 4.355
Figure 1Reference standards reduce variation in reported promoter activities under different measurement conditions. We measured the activity of 2 promoters, J23101 (white columns) and J23150 (grey columns) under seven different measurement conditions and measurement instruments. We varied the media, temperature, cell strain, and plasmid copy number of the promoter test construct. (A) To estimate the per cell GFP synthesis rate we reported the change in fluorescence over a 1 hour period in exponential phase divided by the average absorbance during this period. The coefficient of variation of the GFP synthesis rates across the seven measurement approaches was 49% for J23101 and 39% for J23150. (B) We used the same data and divided the GFP synthesis rate of J23150 (grey bars) by that of J23101 (white bars) in order to calculate the relative promoter activity of J23150 in RPUs. The coefficient of variation of the relative promoter activity across the seven measurement approaches was only 17% suggesting that the relative promoter activity is less sensitive to conditions then absolute activity measured by per cell GFP synthesis rate.
Figure 2Reference standards and units allow independent labs to make sharable measurements. Each laboratory followed the same measurement procedure, measuring relative promoter activities based on GFP concentration measured via a flow cytometer. Measurements were taken in triplicate; the boxes show the highest and lowest measured relative promoter activities and the whiskers show the 95% confidence interval of the mean of the activities. The large range in the 95% confidence interval (extending beyond the highest and lowest measured activities) is partially a function of the small number of replicates (three) that were conducted by each laboratory. The activity of BBa_J23113 was equivalent to the negative control within error for all but one of the laboratories. The measured activities of the other three promoters were fairly consistent across laboratories with less than a 2-fold range of activities measured for each promoter across all labs (BBa_J23150: 0.14 – 0.23; BBa_J23150: 0.38 – 0.606; BBa_J23103: 0.77 – 0.96).
Figure 3Promoter collections can be readily characterized via Relative Promoter Units (RPUs). The five promoters labeled J23### are from a constitutive promoter library and R0040 and R0011 are tet- and lac-repressible promoters, respectively. The activity of the promoters was measured in relative promoter units (RPUs). This collection of promoter may itself be useful for tuning gene expression in engineered systems. The error bars represent the 95% confidence interval of the mean based on nine replicates.