Literature DB >> 19289401

Simple methods to reduce patient dose in a Varian cone beam CT system for delivery verification in pelvic radiotherapy.

P Roxby1, T Kron, F Foroudi, A Haworth, C Fox, A Mullen, J Cramb.   

Abstract

Cone-beam computed tomography (CBCT) is a three-dimensional imaging modality that has recently become available on linear accelerators for radiotherapy patient position verification. It was the aim of the present study to implement simple strategies for reduction of the dose delivered in a commercial CBCT system. The dose delivered in a CBCT procedure (Varian, half-fan acquisition, 650 projections, 125 kVp) was assessed using a cylindrical Perspex phantom (diameter, 32 cm) with a calibrated Farmer type ionisation chamber. A copper filter (thickness, 0.15 mm) was introduced increasing the half value layer of the beam from 5.5 mm Al to 8 mm Al. Image quality and noise were assessed using an image quality phantom (CatPhan) while the exposure settings per projection were varied from 25 ms/80 mA to 2 ms/2 mA per projection. Using the copper filter reduced the dose to the phantom from approximately 45 mGy to 30 mGy at standard settings (centre/periphery weighting 1/3 to 2/3). Multiple CBCT images were acquired for six patients with pelvic malignancies to compare CBCTs with and without a copper filter. Although the reconstructed image is somewhat noisier with the filter, it features similar contrast in the centre of the patient and was often preferred by the radiation oncologist because of greater image uniformity. The X-ray shutters were adjusted to the minimum size required to obtain the desired image volume for a given patient diameter. The simple methods described here reduce the effective dose to patients undergoing daily CBCT and are easy to implement, and initial evidence suggests that they do not affect the ability to identify soft tissue for the purpose of treatment verification.

Entities:  

Mesh:

Year:  2009        PMID: 19289401     DOI: 10.1259/bjr/37579222

Source DB:  PubMed          Journal:  Br J Radiol        ISSN: 0007-1285            Impact factor:   3.039


  8 in total

Review 1.  Are three doses of stereotactic ablative radiotherapy (SABR) more effective than 30 doses of conventional radiotherapy?

Authors:  Anna O Simeonova; Katharina Fleckenstein; Hansjörg Wertz; Anian Frauenfeld; Judit Boda-Heggemann; Frank Lohr; Frederik Wenz
Journal:  Transl Lung Cancer Res       Date:  2012-03

2.  Reduction of radiation exposure by lead curtain shielding in dedicated extremity cone beam CT.

Authors:  C-H Lee; J H Ryu; Y-H Lee; K-H Yoon
Journal:  Br J Radiol       Date:  2015-03-26       Impact factor: 3.039

3.  Patient-based low dose cone beam CT acquisition settings for prostate image-guided radiotherapy treatments on a Varian TrueBeam linear accelerator.

Authors:  Maria Antonietta Piliero; Margherita Casiraghi; Davide Giovanni Bosetti; Simona Cima; Letizia Deantonio; Stefano Leva; Francesco Martucci; Marino Tettamanti; Francesco Pupillo; Luca Bellesi; Antonella Richetti; Stefano Presilla
Journal:  Br J Radiol       Date:  2020-08-27       Impact factor: 3.039

4.  Accounting for patient size in the optimization of dose and image quality of pelvis cone beam CT protocols on the Varian OBI system.

Authors:  Tim J Wood; Craig S Moore; Carl J Horsfield; John R Saunderson; Andrew W Beavis
Journal:  Br J Radiol       Date:  2015-09-30       Impact factor: 3.039

5.  Introduction of online adaptive radiotherapy for bladder cancer through a multicentre clinical trial (Trans-Tasman Radiation Oncology Group 10.01): Lessons learned.

Authors:  Daniel Pham; Paul Roxby; Tomas Kron; Aldo Rolfo; Farshad Foroudi
Journal:  J Med Phys       Date:  2013-04

6.  Dose reduction potential of using gold fiducial markers for kilovoltage image-guided radiotherapy.

Authors:  Yoshiki Takei; Hajime Monzen; Mikoto Tamura; Hiroshi Doi; Yasumasa Nishimura
Journal:  J Appl Clin Med Phys       Date:  2020-09-22       Impact factor: 2.102

7.  Registration accuracy with the low dose kilovoltage cone-beam CT: A phantom study.

Authors:  Yoshiki Takei; Hajime Monzen; Kenji Matsumoto; Kohei Hanaoka; Mikoto Tamura; Yasumasa Nishimura
Journal:  BJR Open       Date:  2019-08-29

8.  CBCT imaging: a simple approach for optimising and evaluating concomitant imaging doses, based on patient-specific attenuation, during radiotherapy pelvis treatment.

Authors:  Caroline Ordóñez-Sanz; Mark Cowen; Neda Shiravand; Niall D MacDougall
Journal:  Br J Radiol       Date:  2021-08-01       Impact factor: 3.039

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.