Diagnostic accuracy of a home blood pressure monitor to detect atrial fibrillation.

G S Stergiou1, N Karpettas, A Protogerou, E G Nasothimiou, M Kyriakidis.   

Abstract

Atrial fibrillation (AF) is the most common sustained arrhythmia and is associated with an increased long-term risk of stroke. A screening test for early diagnosis has the potential to prevent AF-related strokes. This study assessed the diagnostic accuracy of an automated device for self-home blood pressure (BP) monitoring, which implements an algorithm for AF detection. A modified, automated oscillometric device for self-home BP monitoring (Microlife BPA100 Plus, Microlife, Heerbrugg, Switzerland) with an AF detector was used to carry out triplicate BP measurements in subjects with sinus rhythm, AF and non-AF arrhythmias. During each BP measurement, the electrocardiogram (ECG) was recorded simultaneously. A total of 217 simultaneous BP measurements and ECG recordings were obtained from 73 subjects. Twenty-seven subjects (37%) had AF, 23 (31%) non-AF arrhythmias and 23 (31%) had sinus rhythm. A single measurement had 93% sensitivity and 89% specificity for detecting AF. For two measurements, in which one of them was required to detect AF, the sensitivity was 100% and specificity 76%, whereas for three measurements, in which two of them were required to detect AF, the sensitivity was 100% and specificity 89% (kappa=0.86 for an agreement with ECG). Using the latter approach, there were five false positive cases all having irregularities in approximately 50% of the heartbeats. In patients with tachyarrhythmia, the device underestimated heart rate. These data suggest that an electronic device for self-home BP monitoring, which implements an algorithm for AF diagnosis has an excellent diagnostic accuracy and might, therefore, be used as a reliable screening test for the early diagnosis.

Entities:  

Mesh:

Year:  2009        PMID: 19279661     DOI: 10.1038/jhh.2009.5

Source DB:  PubMed          Journal:  J Hum Hypertens        ISSN: 0950-9240            Impact factor:   3.012


  29 in total

1.  Screening for Atrial Fibrillation During Automatic Blood Pressure Measurements.

Authors:  Andrew Lowe; Timothy H Oh; Ralph Stewart
Journal:  IEEE J Transl Eng Health Med       Date:  2018-10-09       Impact factor: 3.316

2.  Validation of a simple method for atrial fibrillation screening in patients with stroke.

Authors:  C Gandolfo; M Balestrino; C Bruno; C Finocchi; N Reale
Journal:  Neurol Sci       Date:  2015-04-30       Impact factor: 3.307

3.  2021 ISHNE/HRS/EHRA/APHRS Expert Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia-Pacific Heart Rhythm Society.

Authors:  Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yu-Feng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg
Journal:  Circ Arrhythm Electrophysiol       Date:  2021-02-12

4.  False detection of atrial fibrillation in children by a blood pressure monitor with atrial fibrillation detection function.

Authors:  Adrian Justin Cheung; Bernard Man Yung Cheung
Journal:  BMJ Case Rep       Date:  2015-01-22

5.  2021 ISHNE/HRS/EHRA/APHRS Collaborative Statement on mHealth in Arrhythmia Management: Digital Medical Tools for Heart Rhythm Professionals: From the International Society for Holter and Noninvasive Electrocardiology/Heart Rhythm Society/European Heart Rhythm Association/Asia Pacific Heart Rhythm Society.

Authors:  Niraj Varma; Iwona Cygankiewicz; Mintu P Turakhia; Hein Heidbuchel; Yufeng Hu; Lin Yee Chen; Jean-Philippe Couderc; Edmond M Cronin; Jerry D Estep; Lars Grieten; Deirdre A Lane; Reena Mehra; Alex Page; Rod Passman; Jonathan P Piccini; Ewa Piotrowicz; Ryszard Piotrowicz; Pyotr G Platonov; Antonio Luiz Ribeiro; Robert E Rich; Andrea M Russo; David Slotwiner; Jonathan S Steinberg; Emma Svennberg
Journal:  Cardiovasc Digit Health J       Date:  2021-01-29

6.  Atrial fibrillation screening during automated blood pressure measurement-Comment on "Diagnostic accuracy of new algorithm to detect atrial fibrillation in a home blood pressure monitor".

Authors:  Yi Chen; Lei Lei; Ji-Guang Wang
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-09-24       Impact factor: 3.738

7.  Accuracy of automated blood pressure measurements in the presence of atrial fibrillation: systematic review and meta-analysis.

Authors:  Christopher E Clark; Sinead T J McDonagh; Richard J McManus
Journal:  J Hum Hypertens       Date:  2019-01-10       Impact factor: 3.012

8.  Blood Pressure in Patients With Atrial Fibrillation: Part 1--Measurement.

Authors:  Debbie L Cohen; Raymond R Townsend
Journal:  J Clin Hypertens (Greenwich)       Date:  2016-08-20       Impact factor: 3.738

Review 9.  Recommendations for home blood pressure monitoring in Latin American countries: A Latin American Society of Hypertension position paper.

Authors:  Raúl Villar; Ramiro A Sánchez; José Boggia; Ernesto Peñaherrera; Jesús Lopez; Weimar Sebba Barroso; Eduardo Barbosa; Leonardo Cobos; Rafael Hernández Hernández; José Andrés Octavio; José Z Parra Carrillo; Agustín J Ramírez; Gianfranco Parati
Journal:  J Clin Hypertens (Greenwich)       Date:  2020-02-12       Impact factor: 3.738

10.  Diagnostic accuracy of a new algorithm to detect atrial fibrillation in a home blood pressure monitor.

Authors:  Tomoyuki Kabutoya; Yasushi Imai; Satoshi Hoshide; Kazuomi Kario
Journal:  J Clin Hypertens (Greenwich)       Date:  2017-09-01       Impact factor: 3.738

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.