Literature DB >> 30405979

Screening for Atrial Fibrillation During Automatic Blood Pressure Measurements.

Andrew Lowe1, Timothy H Oh2, Ralph Stewart3.   

Abstract

Atrial fibrillation (Afib) contributes significantly to overall cardiovascular risk. Widespread screening for Afib in primary care is sometimes performed by palpation, but suffers from low accuracy and is dependent on clinician experience. Algorithms implemented on oscillometric blood pressure devices can detect Afib with high sensitivity and specificity, but information on factors affecting accuracy is scant. Concurrent diagnostic electrocardiogram (ECG) and oscillometry were measured in participants in ECG clinics at two sites. Root mean squared successive difference (RMSSD) and irregularity index (Irrx) were calculated from oscillometric data and used to train logistic regression classifiers. Monte Carlo cross validation with 20 splits was performed to estimate confidence intervals for mean sensitivity and specificity, with various weightings, in the absence or presence of ectopics, and with or without repeated measurements. 707 measurements, including 168 Afib, were collected from 569 participants with mean (standard deviation) age of 63 (16) years. Sensitivity/specificity of RMSSD and Irrx were 0.982/0.908 and 0.986/0.960 respectively when ectopics were included. Excluding ectopics from the data improved specificity by up to 5%. Nevertheless, based on this performance and after accounting for prevalence of Afib in the population aged over 60 years, and estimated costs of healthcare, oscillometric screening for Afib in this age group could return a positive net health-economic benefit.

Entities:  

Keywords:  Atrial fibrillation; biomedical signal processing; medical conditions; medical tests; oscillometric blood pressure

Year:  2018        PMID: 30405979      PMCID: PMC6204330          DOI: 10.1109/JTEHM.2018.2869609

Source DB:  PubMed          Journal:  IEEE J Transl Eng Health Med        ISSN: 2168-2372            Impact factor:   3.316


  22 in total

Review 1.  2014 AHA/ACC/HRS guideline for the management of patients with atrial fibrillation: a report of the American College of Cardiology/American Heart Association Task Force on Practice Guidelines and the Heart Rhythm Society.

Authors:  Craig T January; L Samuel Wann; Joseph S Alpert; Hugh Calkins; Joaquin E Cigarroa; Joseph C Cleveland; Jamie B Conti; Patrick T Ellinor; Michael D Ezekowitz; Michael E Field; Katherine T Murray; Ralph L Sacco; William G Stevenson; Patrick J Tchou; Cynthia M Tracy; Clyde W Yancy
Journal:  J Am Coll Cardiol       Date:  2014-03-28       Impact factor: 24.094

2.  Atrial fibrillation: a comparison of methods to identify cases in general practice.

Authors:  S Somerville; J Somerville; P Croft; M Lewis
Journal:  Br J Gen Pract       Date:  2000-09       Impact factor: 5.386

3.  Economic Burden of Undiagnosed Nonvalvular Atrial Fibrillation in the United States.

Authors:  Mintu P Turakhia; Jason Shafrin; Katalin Bognar; Dana P Goldman; Philip M Mendys; Younos Abdulsattar; Daniel Wiederkehr; Jeffrey Trocio
Journal:  Am J Cardiol       Date:  2015-06-04       Impact factor: 2.778

4.  Comparison of Microlife BP A200 Plus and Omron M6 blood pressure monitors to detect atrial fibrillation in hypertensive patients.

Authors:  Giuseppe Marazzi; Ferdinando Iellamo; Maurizio Volterrani; Mauro Lombardo; Francesco Pelliccia; Daniela Righi; Fabrizia Grieco; Luca Cacciotti; Luigi Iaia; Giuseppe Caminiti; Giuseppe Rosano
Journal:  Adv Ther       Date:  2011-12-21       Impact factor: 3.845

5.  Prevalence of undiagnosed atrial fibrillation and of that not being treated with anticoagulant drugs: the AFABE study.

Authors:  Josep L Clua-Espuny; Iñigo Lechuga-Duran; Ramón Bosch-Princep; Albert Roso-Llorach; Anna Panisello-Tafalla; Jorgina Lucas-Noll; Carles López-Pablo; Lluïsa Queralt-Tomas; Emmanuel Giménez-Garcia; Núria González-Rojas; Miquel Gallofré López
Journal:  Rev Esp Cardiol (Engl Ed)       Date:  2013-05-31

6.  Comparison of the Microlife blood pressure monitor with the Omron blood pressure monitor for detecting atrial fibrillation.

Authors:  Joseph Wiesel; Benjamin Arbesfeld; David Schechter
Journal:  Am J Cardiol       Date:  2014-07-17       Impact factor: 2.778

7.  Detection of atrial fibrillation using a modified microlife blood pressure monitor.

Authors:  Joseph Wiesel; Lorenzo Fitzig; Yehuda Herschman; Frank C Messineo
Journal:  Am J Hypertens       Date:  2009-05-28       Impact factor: 2.689

8.  The use of a modified sphygmomanometer to detect atrial fibrillation in outpatients.

Authors:  Joseph Wiesel; David Wiesel; Ranjit Suri; Frank C Messineo
Journal:  Pacing Clin Electrophysiol       Date:  2004-05       Impact factor: 1.976

9.  High accuracy in automatic detection of atrial fibrillation for Holter monitoring.

Authors:  Kai Jiang; Chao Huang; Shu-ming Ye; Hang Chen
Journal:  J Zhejiang Univ Sci B       Date:  2012-09       Impact factor: 3.066

10.  Triage tests for identifying atrial fibrillation in primary care: a diagnostic accuracy study comparing single-lead ECG and modified BP monitors.

Authors:  Karen Kearley; Mary Selwood; Ann Van den Bruel; Matthew Thompson; David Mant; Fd Richard Hobbs; David Fitzmaurice; Carl Heneghan
Journal:  BMJ Open       Date:  2014-05-02       Impact factor: 2.692

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.