Literature DB >> 19259251

Impact of enhanced resolution, speed and penetration on three-dimensional retinal optical coherence tomography.

Boris Povazay1, Bernd Hofer, Cristiano Torti, Boris Hermann, Alexandre R Tumlinson, Marieh Esmaeelpour, Catherine A Egan, Alan C Bird, Wolfgang Drexler.   

Abstract

: Recent substantial developments in light source and detector technology have initiated a paradigm shift in retinal optical coherence tomography (OCT) performance. Broad bandwidth light sources in the 800 nm and 1060 nm wavelength region enable axial OCT resolutions of 2-3 mum and 5-7 mum, respectively. Novel high speed silicon based CMOS cameras at 800 nm and InGaAs based CCD cameras in combination with frequency domain OCT technology enable data acquisition speeds of up to 47,000 A-scans/s at 1060 nm and up to 312,500 A-scans/s at 800 nm. Combining ultrahigh axial resolution, ultrahigh speed OCT at 800 nm with pancorrected adaptive optics allows volumetric in vivo cellular resolution retinal imaging. Commercially available three-dimensional (3D) retinal OCT at 800 nm (20,000 A-scans/s, 6 mum axial resolution) is compared to ultrahigh speed 3D retinal imaging at 800 nm (160,000 A-scans/s, 2-3 mum axial resolution), high speed 3D choroidal imaging at 1060 nm (47,000 Ascan/ second, 6-7 mum axial resolution) and cellular resolution retinal imaging at 800 nm using adaptive optics OCT at 160,000 A-scans/second with isotropic resolution of ~2 mum. Analysis of the performance of these four imaging modalities applied in normal and pathologic eyes focusing on motion artifact free volumetric retinal imaging and revealing novel, complementary morphological information due to enhanced resolution, speed and penetration is presented.

Entities:  

Mesh:

Year:  2009        PMID: 19259251     DOI: 10.1364/oe.17.004134

Source DB:  PubMed          Journal:  Opt Express        ISSN: 1094-4087            Impact factor:   3.894


  26 in total

1.  Multimodal assessment of microscopic morphology and retinal function in patients with geographic atrophy.

Authors:  Athanasios Panorgias; Robert J Zawadzki; Arlie G Capps; Allan A Hunter; Lawrence S Morse; John S Werner
Journal:  Invest Ophthalmol Vis Sci       Date:  2013-06-26       Impact factor: 4.799

2.  Multi-MHz retinal OCT.

Authors:  Thomas Klein; Wolfgang Wieser; Lukas Reznicek; Aljoscha Neubauer; Anselm Kampik; Robert Huber
Journal:  Biomed Opt Express       Date:  2013-08-30       Impact factor: 3.732

3.  Lamina-specific anatomic magnetic resonance imaging of the human retina.

Authors:  Yi Zhang; Oscar San Emeterio Nateras; Qi Peng; Roman V Kuranov; Joseph M Harrison; Thomas E Milner; Timothy Q Duong
Journal:  Invest Ophthalmol Vis Sci       Date:  2011-09-14       Impact factor: 4.799

4.  Stability in computed optical interferometric tomography (Part II): in vivo stability assessment.

Authors:  Nathan D Shemonski; Adeel Ahmad; Steven G Adie; Yuan-Zhi Liu; Fredrick A South; P Scott Carney; Stephen A Boppart
Journal:  Opt Express       Date:  2014-08-11       Impact factor: 3.894

5.  Three-dimensional motion correction using speckle and phase for in vivo computed optical interferometric tomography.

Authors:  Nathan D Shemonski; Shawn S Ahn; Yuan-Zhi Liu; Fredrick A South; P Scott Carney; Stephen A Boppart
Journal:  Biomed Opt Express       Date:  2014-11-04       Impact factor: 3.732

6.  Ultra-widefield retinal MHz-OCT imaging with up to 100 degrees viewing angle.

Authors:  Jan Philip Kolb; Thomas Klein; Corinna L Kufner; Wolfgang Wieser; Aljoscha S Neubauer; Robert Huber
Journal:  Biomed Opt Express       Date:  2015-04-02       Impact factor: 3.732

7.  Line-field parallel swept source MHz OCT for structural and functional retinal imaging.

Authors:  Daniel J Fechtig; Branislav Grajciar; Tilman Schmoll; Cedric Blatter; Rene M Werkmeister; Wolfgang Drexler; Rainer A Leitgeb
Journal:  Biomed Opt Express       Date:  2015-02-04       Impact factor: 3.732

Review 8.  High-speed OCT light sources and systems [Invited].

Authors:  Thomas Klein; Robert Huber
Journal:  Biomed Opt Express       Date:  2017-01-13       Impact factor: 3.732

Review 9.  Review of adaptive optics OCT (AO-OCT): principles and applications for retinal imaging [Invited].

Authors:  Michael Pircher; Robert J Zawadzki
Journal:  Biomed Opt Express       Date:  2017-04-19       Impact factor: 3.732

10.  Wide-field high-speed space-division multiplexing optical coherence tomography using an integrated photonic device.

Authors:  Yongyang Huang; Mudabbir Badar; Arthur Nitkowski; Aaron Weinroth; Nelson Tansu; Chao Zhou
Journal:  Biomed Opt Express       Date:  2017-07-28       Impact factor: 3.732

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.