Literature DB >> 19253907

Measuring leg length and offset with an imageless navigation system during total hip arthroplasty: is it really accurate?

Tobias Renkawitz1, Tibor Schuster, Thomas Herold, Holger Goessmann, Ernst Sendtner, Joachim Grifka, Thomas Kalteis.   

Abstract

BACKGROUND: A novel imageless measurement algorithm to assess leg length (LL) and offset (OS) changes during total hip arthroplasty (THA) has been established, the purpose of this study was to describe the process and establish whether or not it is accurate.
METHODS: THA was performed on 17 cadaver hip specimens. LL and OS changes were determined intra-operatively, using an imageless navigation system. Pre- and postoperatively, all specimens had a computed tomography scan (CT) and the LL and OS changes were analysed by two blinded investigators.
RESULTS: With mean differences of less than 1 mm (LL, 0.74; SD, 2.4 mm; OS, 0.89; SD, 1.8 mm) supported by substantial significant correlations [r = 0.83 (LL) and r = 0.92 (OS)] imageless navigation values demonstrated a high accuracy when compared to CT measurements.
CONCLUSIONS: Intra-operative LL and OS measures are reliable and accurate when using an imageless calculation algorithm which stores the position of the femoral reference frame in relation to the pelvic coordinate system before and after reconstruction.

Entities:  

Mesh:

Year:  2009        PMID: 19253907     DOI: 10.1002/rcs.250

Source DB:  PubMed          Journal:  Int J Med Robot        ISSN: 1478-5951            Impact factor:   2.547


  6 in total

1.  [Principles and new concepts in computer-navigated total hip arthroplasty].

Authors:  T Renkawitz; M Wörner; E Sendtner; M Weber; P Lechler; J Grifka
Journal:  Orthopade       Date:  2011-12       Impact factor: 1.087

2.  Leg length and offset measures with a pinless femoral reference array during THA.

Authors:  Tobias Renkawitz; Tibor Schuster; Joachim Grifka; Thomas Kalteis; Ernst Sendtner
Journal:  Clin Orthop Relat Res       Date:  2009-09-19       Impact factor: 4.176

3.  Hip offset in total hip arthroplasty: quantitative measurement with navigation.

Authors:  Manish Dastane; Lawrence D Dorr; Rupesh Tarwala; Zhinian Wan
Journal:  Clin Orthop Relat Res       Date:  2011-02       Impact factor: 4.176

4.  Does computer-assisted surgery benefit leg length restoration in total hip replacement? Navigation versus conventional freehand.

Authors:  Alfonso Manzotti; Pietro Cerveri; Elena De Momi; Chris Pullen; Norberto Confalonieri
Journal:  Int Orthop       Date:  2009-11-11       Impact factor: 3.075

5.  Minimally invasive computer-navigated total hip arthroplasty, following the concept of femur first and combined anteversion: design of a blinded randomized controlled trial.

Authors:  Tobias Renkawitz; Martin Haimerl; Lars Dohmen; Sabine Gneiting; Melanie Wegner; Nicole Ehret; Claudia Buchele; Mario Schubert; Philipp Lechler; Michael Woerner; Ernst Sendtner; Tibor Schuster; Kurt Ulm; Robert Springorum; Joachim Grifka
Journal:  BMC Musculoskelet Disord       Date:  2011-08-19       Impact factor: 2.362

6.  Accuracy of a portable accelerometer-based navigation system for cup placement and intraoperative leg length measurement in total hip arthroplasty: a cross-sectional study.

Authors:  Hiromasa Tanino; Yasuhiro Nishida; Ryo Mitsutake; Hiroshi Ito
Journal:  BMC Musculoskelet Disord       Date:  2021-03-23       Impact factor: 2.362

  6 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.