Literature DB >> 19251516

Evaluating the robustness of dual apodization with cross-correlation.

Chi Hyung Seo1, Jesse T Yen.   

Abstract

We have recently presented a new method to suppress side lobes and clutter in ultrasound imaging called dual apodization with cross-correlation (DAX). However, due to the random nature of speckle, artifactual black spots may arise with DAX-processed images. In this paper, we present one possible solution, called dynamic DAX, to reduce these black spots. We also evaluate the robustness of dynamic DAX in the presence of phase aberration and noise. Simulation results using a 5 MHz, 128-element linear array are presented using dynamic DAX with aberrator strengths ranging from 25 ns root-mean-square (RMS) to 45 ns RMS and correlation lengths of 3 mm and 5 mm. When simulating a 3 mm diameter anechoic cyst, at least 100% improvement in the contrast-to-noise ratio (CNR) compared with standard beamforming is seen using dynamic DAX, except in the most severe case. Layers of pig skin, fat, and muscle were used as experimental aberrators. Simulation and experimental results are also presented using dynamic DAX in the presence of noise. With a system signal-to-noise ratio (SNR) of at least 15 dB, we have a CNR improvement of more than 100% compared with standard beamforming. This work shows that dynamic DAX is able to improve the contrast-to-noise ratio reliably in the presence of phase aberration and noise.

Entities:  

Mesh:

Year:  2009        PMID: 19251516      PMCID: PMC2897715          DOI: 10.1109/TUFFC.2009.1038

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  15 in total

1.  Adaptive imaging and spatial compounding in the presence of aberration.

Authors:  Jeremy J Dahl; Drake A Guenther; Gregg E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2005-07       Impact factor: 2.725

2.  Phase aberration correction using near-field signal redundancy. I. Principles [Ultrasound medical imaging].

Authors:  Y Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1997       Impact factor: 2.725

3.  Phase aberration correction using near-field signal redundancy. II. Experimental results.

Authors:  Y Li; D Robinson; D Carpenter
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1997       Impact factor: 2.725

4.  Comparisons of image quality factors for phase aberration correction with diffuse and point targets: theory and experiments.

Authors:  D Zhao; G E Trahey
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1991       Impact factor: 2.725

5.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

6.  Performance evaluation of coherence-based adaptive imaging using clinical breast data.

Authors:  Shun-Li Wang; Chen-Han Chang; Hsin-Chia Yang; Yi-Hong Chou; Pai-Chi Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-08       Impact factor: 2.725

7.  Direct estimation of aberrating delays in pulse-echo imaging systems.

Authors:  D Rachlin
Journal:  J Acoust Soc Am       Date:  1990-07       Impact factor: 1.840

8.  Phase aberration correction in medical ultrasound using speckle brightness as a quality factor.

Authors:  L Nock; G E Trahey; S W Smith
Journal:  J Acoust Soc Am       Date:  1989-05       Impact factor: 1.840

9.  Texture of B-mode echograms: 3-D simulations and experiments of the effects of diffraction and scatterer density.

Authors:  B J Oosterveld; J M Thijssen; W A Verhoef
Journal:  Ultrason Imaging       Date:  1985-04       Impact factor: 1.578

10.  Ultrasonic velocity and attenuation in mammalian tissues.

Authors:  R C Chivers; R J Parry
Journal:  J Acoust Soc Am       Date:  1978-03       Impact factor: 1.840

View more
  8 in total

1.  Effects of dual apodization with cross-correlation on tissue harmonic and pulse inversion harmonic imaging in the presence of phase aberration.

Authors:  Junseob Shin; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

2.  Ultrasonic Reverberation Clutter Suppression Using Multiphase Apodization With Cross Correlation.

Authors:  Junseob Shin; Yu Chen; Harshawn Malhi; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2016-11       Impact factor: 2.725

3.  The Impact of Model-Based Clutter Suppression on Cluttered, Aberrated Wavefronts.

Authors:  Kazuyuki Dei; Brett Byram
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2017-07-20       Impact factor: 2.725

4.  A Robust Method for Ultrasound Beamforming in the Presence of Off-Axis Clutter and Sound Speed Variation.

Authors:  Kazuyuki Dei; Brett Byram
Journal:  Ultrasonics       Date:  2018-04-25       Impact factor: 2.890

5.  Performance improvement of Fresnel beamforming using dual apodization with cross-correlation.

Authors:  Man M Nguyen; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2013-03       Impact factor: 2.725

6.  Synergistic enhancements of ultrasound image contrast with a combination of phase aberration correction and dual apodization with cross-correlation.

Authors:  Junseob Shin; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2012-09       Impact factor: 2.725

7.  Subaperture Processing-Based Adaptive Beamforming for Photoacoustic Imaging.

Authors:  Rashid Al Mukaddim; Rifat Ahmed; Tomy Varghese
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2021-06-29       Impact factor: 3.267

8.  Dual-/tri-apodization techniques for high frequency ultrasound imaging: a simulation study.

Authors:  Jin Ho Sung; Jong Seob Jeong
Journal:  Biomed Eng Online       Date:  2014-10-11       Impact factor: 2.819

  8 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.