Literature DB >> 33606629

Subaperture Processing-Based Adaptive Beamforming for Photoacoustic Imaging.

Rashid Al Mukaddim, Rifat Ahmed, Tomy Varghese.   

Abstract

Delay-and-sum (DAS) beamformers, when applied to photoacoustic (PA) image reconstruction, produce strong sidelobes due to the absence of transmit focusing. Consequently, DAS PA images are often severely degraded by strong off-axis clutter. For preclinical in vivo cardiac PA imaging, the presence of these noise artifacts hampers the detectability and interpretation of PA signals from the myocardial wall, crucial for studying blood-dominated cardiac pathological information and to complement functional information derived from ultrasound imaging. In this article, we present PA subaperture processing (PSAP), an adaptive beamforming method, to mitigate these image degrading effects. In PSAP, a pair of DAS reconstructed images is formed by splitting the received channel data into two complementary nonoverlapping subapertures. Then, a weighting matrix is derived by analyzing the correlation between subaperture beamformed images and multiplied with the full-aperture DAS PA image to reduce sidelobes and incoherent clutter. We validated PSAP using numerical simulation studies using point target, diffuse inclusion and microvasculature imaging, and in vivo feasibility studies on five healthy murine models. Qualitative and quantitative analysis demonstrate improvements in PAI image quality with PSAP compared to DAS and coherence factor weighted DAS (DAS CF ). PSAP demonstrated improved target detectability with a higher generalized contrast-to-noise (gCNR) ratio in vasculature simulations where PSAP produces 19.61% and 19.53% higher gCNRs than DAS and DAS CF , respectively. Furthermore, PSAP provided higher image contrast quantified using contrast ratio (CR) (e.g., PSAP produces 89.26% and 11.90% higher CR than DAS and DAS CF in vasculature simulations) and improved clutter suppression.

Entities:  

Mesh:

Year:  2021        PMID: 33606629      PMCID: PMC8330397          DOI: 10.1109/TUFFC.2021.3060371

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   3.267


  65 in total

1.  The application of compressed sensing for photo-acoustic tomography.

Authors:  Jean Provost; Frédéric Lesage
Journal:  IEEE Trans Med Imaging       Date:  2008-10-31       Impact factor: 10.048

Review 2.  The complete blood count: physiologic basis and clinical usage.

Authors:  L R Dixon
Journal:  J Perinat Neonatal Nurs       Date:  1997-12       Impact factor: 1.638

Review 3.  Recent advances toward preclinical and clinical translation of photoacoustic tomography: a review.

Authors:  Paul Kumar Upputuri; Manojit Pramanik
Journal:  J Biomed Opt       Date:  2017-04-01       Impact factor: 3.170

4.  ASAP: Super-Contrast Vasculature Imaging Using Coherence Analysis and High Frame-Rate Contrast Enhanced Ultrasound.

Authors:  Antonio Stanziola; Chee Hau Leow; Eleni Bazigou; Peter D Weinberg; Meng-Xing Tang
Journal:  IEEE Trans Med Imaging       Date:  2018-02-28       Impact factor: 10.048

5.  SNR-dependent coherence-based adaptive imaging for high-frame-rate ultrasonic and photoacoustic imaging.

Authors:  Yu-Hsin Wang; Pai-Chi Li
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2014-08       Impact factor: 2.725

6.  Coherence-Weighted Synthetic Focusing Applied to Photoacoustic Imaging Using a High-Frequency Annular-Array Transducer.

Authors:  Parag V Chitnis; Orlando Aristizábal; Erwan Filoux; Ashwin Sampathkumar; Jonathan Mamou; Jeffrey A Ketterling
Journal:  Ultrason Imaging       Date:  2015-04-28       Impact factor: 1.578

7.  Double-Stage Delay Multiply and Sum Beamforming Algorithm: Application to Linear-Array Photoacoustic Imaging.

Authors:  Moein Mozaffarzadeh; Ali Mahloojifar; Mahdi Orooji; Saba Adabi; Mohammadreza Nasiriavanaki
Journal:  IEEE Trans Biomed Eng       Date:  2017-04-05       Impact factor: 4.538

8.  An approach to unbiased subsample interpolation for motion tracking.

Authors:  Matthew M McCormick; Tomy Varghese
Journal:  Ultrason Imaging       Date:  2013-04       Impact factor: 1.578

9.  Insights into photoacoustic speckle and applications in tumor characterization.

Authors:  Eno Hysi; Muhannad N Fadhel; Michael J Moore; Jason Zalev; Eric M Strohm; Michael C Kolios
Journal:  Photoacoustics       Date:  2019-04-05

10.  The double-stage delay-multiply-and-sum image reconstruction method improves imaging quality in a LED-based photoacoustic array scanner.

Authors:  Moein Mozaffarzadeh; Ali Hariri; Colman Moore; Jesse V Jokerst
Journal:  Photoacoustics       Date:  2018-09-18
View more
  1 in total

1.  Improving Minimum Variance Beamforming with Sub-Aperture Processing for Photoacoustic Imaging.

Authors:  Rashid Al Mukaddim; Rifat Ahmed; Tomy Varghese
Journal:  Annu Int Conf IEEE Eng Med Biol Soc       Date:  2021-11
  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.