Literature DB >> 23475913

Performance improvement of Fresnel beamforming using dual apodization with cross-correlation.

Man M Nguyen1, Jesse T Yen.   

Abstract

Fresnel beamforming is a beamforming method that has a delay profile with a shape similar to a physical Fresnel lens. With 4 to 8 transmit channels, 2 receive channels, and a network of single-pole/single-throw switches, Fresnel beamforming can reduce the size, cost, and complexity of a beamformer. The performance of Fresnel beamforming is highly dependent on focal errors resulting from phase wraparound and quantization of its delay profile. Previously, we demonstrated that the performance of Fresnel beamforming relative to delayand- sum (DAS) beamforming is comparable for linear arrays at f-number = 2 and 50% bandwidth. However, focal errors for Fresnel beamforming are larger because of larger path length differences between elements, as in the case of curvilinear arrays compared with linear arrays. In this paper, we present the concept and performance evaluation of Fresnel beamforming combined with a novel clutter suppression method called dual apodization with cross-correlation (DAX) for curvilinear arrays. The contrast-to-noise ratios (CNRs) of Fresnel beamforming followed by DAX are highest at f-number = 3. At f-number = 3, the experimental results show that using DAX, the CNR for Fresnel beamforming improves from 3.7 to 10.6, compared with a CNR of 5.2 for DAS beamforming. Spatial resolution is shown to be unaffected by DAX. At f-number = 3, the lateral beamwidth and axial pulse length for Fresnel beamforming with DAX are 1.44 and 1.00 mm larger than those for DAS beamforming (about 14% and 21% larger), respectively. These experimental results are in good agreement with simulation results.

Entities:  

Mesh:

Year:  2013        PMID: 23475913      PMCID: PMC3609545          DOI: 10.1109/TUFFC.2013.2589

Source DB:  PubMed          Journal:  IEEE Trans Ultrason Ferroelectr Freq Control        ISSN: 0885-3010            Impact factor:   2.725


  7 in total

1.  Optimal apodization design for medical ultrasound using constrained least squares part II: simulation results.

Authors:  Drake A Guenther; William F Walker
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2007-02       Impact factor: 2.725

2.  Calculation of pressure fields from arbitrarily shaped, apodized, and excited ultrasound transducers.

Authors:  J A Jensen; N B Svendsen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  1992       Impact factor: 2.725

3.  Sidelobe suppression in ultrasound imaging using dual apodization with cross-correlation.

Authors:  Chi Hyung Seo; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008-10       Impact factor: 2.725

4.  Fresnel-based beamforming for low-cost portable ultrasound.

Authors:  Man Minh Nguyen; Jay Mung; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2011-01       Impact factor: 2.725

5.  Newly-developed, forward-viewing echoendoscope: a comparative pilot study to the standard echoendoscope in the imaging of abdominal organs and feasibility of endoscopic ultrasound-guided interventions.

Authors:  Takuji Iwashita; Yousuke Nakai; John G Lee; Do Hyun Park; V Raman Muthusamy; Kenneth J Chang
Journal:  J Gastroenterol Hepatol       Date:  2012-02       Impact factor: 4.029

6.  Computer-aided B-mode ultrasound diagnosis of hepatic steatosis: a feasibility study.

Authors:  Johan M Thijssen; Alexander Starke; Gert Weijers; Alois Haudum; Kathrin Herzog; Peter Wohlsein; Jürgen Rehage; Chris L De Korte
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2008       Impact factor: 2.725

7.  Evaluating the robustness of dual apodization with cross-correlation.

Authors:  Chi Hyung Seo; Jesse T Yen
Journal:  IEEE Trans Ultrason Ferroelectr Freq Control       Date:  2009-02       Impact factor: 2.725

  7 in total
  1 in total

1.  Multi-Focus Beamforming for Thermal Strain Imaging Using a Single Ultrasound Linear Array Transducer.

Authors:  Man M Nguyen; Xuan Ding; Steven A Leers; Kang Kim
Journal:  Ultrasound Med Biol       Date:  2017-03-18       Impact factor: 2.998

  1 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.