Literature DB >> 19250077

Tricuspid incompetence following permanent pacemaker implantation.

Marc Klutstein1, Jonathan Balkin, Adi Butnaru, Michael Ilan, Amnon Lahad, David Rosenmann.   

Abstract

AIM: Severe tricuspid insufficiency (TI) after permanent pacemaker implantation (PPI) has been described in small series of patients, though its incidence is not known.
METHODS: We retrospectively analyzed the data of 545 patients who underwent PPI and had Doppler echocardiograms performed before and after the procedure. We excluded 135 patients who had > or =moderate TI on the 1st Doppler echocardiogram.
RESULTS: Group 1 included 75 patients (18.3%) who had a >2 grades worsening of TI, and group 2 included 335 patients (82%) with <2 grade increase in TI after PPI. Patients in group 1 were 77 +/- 7 years of age, versus 72 +/- 10 years in group 2 (P < 0.001). There was no difference in left ventricular size and function. The TI gradient before PPI was higher in group 2 (25 +/- 13 mmHg versus 19 +/- 12 mmHg [P < 0.001]), though within the normal range in both groups. The mitral E/A ratio was 0.98 in group 1 versus 1.42 in group 2 (P < 0.001). The systolic TI gradient after implantation was 42 +/- 12 mmHg in group 1, versus 33 +/- 8 mmHg in group 2 (P < 0.001).
CONCLUSION: Worsening of TI after PPI was not rare and was observed more often in older patients, with abnormal LV relaxation and who developed pulmonary hypertension after the procedure.

Entities:  

Mesh:

Year:  2009        PMID: 19250077     DOI: 10.1111/j.1540-8159.2008.02269.x

Source DB:  PubMed          Journal:  Pacing Clin Electrophysiol        ISSN: 0147-8389            Impact factor:   1.976


  17 in total

1.  Clinical significance of increased tricuspid valve incompetence following implantation of ventricular leads.

Authors:  Giselle A Baquero; Pradeep Yadav; Joshua B Skibba; Javier E Banchs; Latoya N Linton-Frazier; Eugene J Lengerich; Soraya M Samii; Erica Penny-Peterson; Deborah L Wolbrette; Jerry C Luck; Gerald V Naccarelli; Mario D Gonzalez
Journal:  J Interv Card Electrophysiol       Date:  2013-12       Impact factor: 1.900

2.  Echocardiographic assessment of tricuspid regurgitation and pericardial effusion after cardiac device implantation.

Authors:  Katarzyna Wiechecka; Bartosz Wiechecki; Agnieszka Kapłon-Cieślicka; Agata Tymińska; Monika Budnik; Dominika Hołowaty; Krzysztof Jakubowski; Marcin Michalak; Elżbieta Świętoń; Przemysław Stolarz; Roman Steckiewicz; Marcin Grabowski; Piotr Scisło; Janusz Kochanowski; Krzysztof J Filipiak; Grzegorz Opolski
Journal:  Cardiol J       Date:  2019-06-21       Impact factor: 2.737

Review 3.  Tricuspid valve incompetence following implantation of ventricular leads.

Authors:  Giselle A Baquero; Jerry Luck; Gerald V Naccarelli; Mario D Gonzalez; Javier E Banchs
Journal:  Curr Heart Fail Rep       Date:  2015-04

4.  Impact of implantable transvenous device lead location on severity of tricuspid regurgitation.

Authors:  Karima Addetia; Francesco Maffessanti; Anuj Mediratta; Megan Yamat; Lynn Weinert; Joshua D Moss; Hemal M Nayak; Martin C Burke; Amit R Patel; Eric Kruse; Valluvan Jeevanandam; Victor Mor-Avi; Roberto M Lang
Journal:  J Am Soc Echocardiogr       Date:  2014-08-14       Impact factor: 5.251

5.  Predictors of severe tricuspid regurgitation in patients with permanent pacemaker or automatic implantable cardioverter-defibrillator leads.

Authors:  Mohammad Q Najib; Satya S Vittala; Suresh Challa; Amol Raizada; Fernando J Tondato; Howard R Lee; Hari P Chaliki
Journal:  Tex Heart Inst J       Date:  2013

6.  Pacemaker-induced tricuspid regurgitation is uncommon immediately post-implantation.

Authors:  Daniel P Rothschild; James A Goldstein; Nathan Kerner; Amr E Abbas; Meet Patel; Wai Shun Wong
Journal:  J Interv Card Electrophysiol       Date:  2017-07-06       Impact factor: 1.900

7.  [Right heart failure resulting from pacemaker lead-induced tricuspid valve regurgitation].

Authors:  T Schroeter; E Strotdrees; N Doll; F W Mohr
Journal:  Herzschrittmacherther Elektrophysiol       Date:  2011-06

8.  Tricuspid Regurgitation and Mortality in Patients With Transvenous Permanent Pacemaker Leads.

Authors:  Francesca N Delling; Zena K Hassan; Gail Piatkowski; Connie W Tsao; Alefiyah Rajabali; Lawrence J Markson; Peter J Zimetbaum; Warren J Manning; James D Chang; Kenneth J Mukamal
Journal:  Am J Cardiol       Date:  2016-01-06       Impact factor: 2.778

Review 9.  Tricuspid regurgitation following implantation of a pacemaker/cardioverter-defibrillator.

Authors:  Maha A Al-Mohaissen; Kwan Leung Chan
Journal:  Curr Cardiol Rep       Date:  2013-05       Impact factor: 2.931

10.  Pacemaker lead-associated tricuspid regurgitation in patients with or without pre-existing right ventricular dilatation.

Authors:  Martin Riesenhuber; Andreas Spannbauer; Marianne Gwechenberger; Thomas Pezawas; Christoph Schukro; Günter Stix; Matthias Schneider; Georg Goliasch; Anahit Anvari; Thomas Wrba; Cesar Khazen; Martin Andreas; Günther Laufer; Christian Hengstenberg; Mariann Gyongyosi
Journal:  Clin Res Cardiol       Date:  2021-02-10       Impact factor: 5.460

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.