Literature DB >> 19247729

Patient activity after total hip arthroplasty declines with advancing age.

Stefan Kinkel1, Nicole Wollmerstedt, Jennifer A Kleinhans, Christian Hendrich, Christian Heisel.   

Abstract

Evaluation of patient activity is essential for clinical decision making before THA. To correlate age progression to patient activity after THA, we determined the number of walking cycles of 105 patients in different age groups by decades. Patients on average performed 6144 walking cycles per day (2.24 million cycles per year). Men were more active than women. The highest activity occurred in patients between 50 and 59 years of age, with a constant decrease in activity with advancing age. However, within age groups, we observed up to sixfold differences in the number of walking cycles per day. In addition to declining activity with advancing age, higher body mass index correlated with lower step counts. The high mean measured number of walking cycles, which were even higher than those reported for subjects without an arthroplasty, suggests patients benefit from THA. Female gender, advanced age, and obesity correlated with lower activity. Owing to the high intragroup variability of our results, preoperative evaluation of patient activity levels, individual patient factors, and patient demands, should be considered in clinical practice.

Entities:  

Mesh:

Year:  2009        PMID: 19247729      PMCID: PMC2706348          DOI: 10.1007/s11999-009-0756-3

Source DB:  PubMed          Journal:  Clin Orthop Relat Res        ISSN: 0009-921X            Impact factor:   4.176


  21 in total

1.  Step activity monitor: increased accuracy in quantifying ambulatory activity.

Authors:  E F Shepherd; E Toloza; C D McClung; T P Schmalzried
Journal:  J Orthop Res       Date:  1999-09       Impact factor: 3.494

2.  Comparative study of the activity of total hip arthroplasty patients and normal subjects.

Authors:  A A Goldsmith; D Dowson; B M Wroblewski; P D Siney; P A Fleming; J M Lane; M H Stone; R Walker
Journal:  J Arthroplasty       Date:  2001-08       Impact factor: 4.757

Review 3.  Wear and periprosthetic osteolysis: the problem.

Authors:  W H Harris
Journal:  Clin Orthop Relat Res       Date:  2001-12       Impact factor: 4.176

4.  Duration and frequency of every day activities in total hip patients.

Authors:  M Morlock; E Schneider; A Bluhm; M Vollmer; G Bergmann; V Müller; M Honl
Journal:  J Biomech       Date:  2001-07       Impact factor: 2.712

5.  Validation of a simple mechanical accelerometer (pedometer) for the estimation of walking activity.

Authors:  E J Bassey; H M Dallosso; P H Fentem; J M Irving; J M Patrick
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1987

6.  Walking activities and wear of prostheses.

Authors:  B B Seedhom; N C Wallbridge
Journal:  Ann Rheum Dis       Date:  1985-12       Impact factor: 19.103

7.  The walking activity of patients with artificial hip joints.

Authors:  N Wallbridge; D Dowson
Journal:  Eng Med       Date:  1982-04

8.  The use of pedometer and actometer in studying daily physical activity in man. Part II: validity of pedometer and actometer measuring the daily physical activity.

Authors:  W H Saris; R A Binkhorst
Journal:  Eur J Appl Physiol Occup Physiol       Date:  1977-10-31

9.  The John Charnley Award. Wear is a function of use, not time.

Authors:  T P Schmalzried; E F Shepherd; F J Dorey; W O Jackson; M dela Rosa; F Fa'vae; H A McKellop; C D McClung; J Martell; J R Moreland; H C Amstutz
Journal:  Clin Orthop Relat Res       Date:  2000-12       Impact factor: 4.176

10.  The new demands by patients in the modern era of total joint arthroplasty : a point of view.

Authors:  J Bohannon Mason
Journal:  Clin Orthop Relat Res       Date:  2008-01-03       Impact factor: 4.176

View more
  20 in total

1.  The prevalence of groin pain after metal-on-metal total hip arthroplasty and total hip resurfacing.

Authors:  Robert B Bartelt; Brandon J Yuan; Robert T Trousdale; Rafael J Sierra
Journal:  Clin Orthop Relat Res       Date:  2010-09       Impact factor: 4.176

2.  Function and activity after minimally invasive total hip arthroplasty compared to a healthy population.

Authors:  Eberhard von Rottkay; Lars Rackwitz; Maximilian Rudert; Ulrich Nöth; Johannes Christian Reichert
Journal:  Int Orthop       Date:  2017-07-12       Impact factor: 3.075

Review 3.  [Tribology in hip arthroplasty : Benefits of different materials].

Authors:  J Philippe Kretzer; Maximilian Uhler; Sebastian Jäger; Therese Bormann; Robert Sonntag; Mareike Schonhoff; Stefan Schröder
Journal:  Orthopade       Date:  2021-02-25       Impact factor: 1.087

4.  Nickel-Titanium peripheral stents: Which is the best criterion for the multi-axial fatigue strength assessment?

Authors:  Francesca Berti; Pei-Jiang Wang; Andrea Spagnoli; Giancarlo Pennati; Francesco Migliavacca; Elazer R Edelman; Lorenza Petrini
Journal:  J Mech Behav Biomed Mater       Date:  2020-10-18

5.  Fatigue performance of angle-stable tibial nail interlocking screws.

Authors:  Mark Lenz; Boyko Gueorguiev; Robert Geoff Richards; Thomas Mückley; Gunther Olaf Hofmann; Dankward Höntzsch; Markus Windolf
Journal:  Int Orthop       Date:  2012-08-09       Impact factor: 3.075

6.  Low wear rates seen in THAs with highly crosslinked polyethylene at 9 to 14 years in patients younger than age 50 years.

Authors:  Kevin L Garvin; Tyler C White; Anand Dusad; Curtis W Hartman; John Martell
Journal:  Clin Orthop Relat Res       Date:  2015-12       Impact factor: 4.176

7.  Long-term survival of the uncemented Balgrist total hip replacement cup.

Authors:  Jiri Gallo; Jiri Lostak; Katerina Langova
Journal:  Int Orthop       Date:  2013-06-08       Impact factor: 3.075

8.  A SIX-WEEK SUPERVISED EXERCISE AND EDUCATIONAL INTERVENTION AFTER TOTAL HIP ARTHROPLASTY: A CASE SERIES.

Authors:  Federico Pozzi; Kathleen Madara; Joseph A Zeni
Journal:  Int J Sports Phys Ther       Date:  2017-04

9.  Total hip arthroplasty in patients 50 years or less: do we improve activity profiles?

Authors:  Margaret Kuhn; Marcie Harris-Hayes; Karen Steger-May; Gail Pashos; John C Clohisy
Journal:  J Arthroplasty       Date:  2013-03-15       Impact factor: 4.757

10.  Hip abductor strength and fatigue are associated with activity levels more than 1 year after total hip replacement.

Authors:  Kharma C Foucher; Christopher C Cinnamon; Colleen A Ryan; Samuel J Chmell; Kris Dapiton
Journal:  J Orthop Res       Date:  2017-11-28       Impact factor: 3.494

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.