Literature DB >> 19241769

Correlation of anterior chamber angle and ciliary sulcus diameters with white-to-white corneal diameter in high myopes using artemis VHF digital ultrasound.

Dan Z Reinstein1, Timothy J Archer, Ronald H Silverman, Mark J Rondeau, D Jackson Coleman.   

Abstract

PURPOSE: To determine whether horizontal angle diameter and sulcus diameter can be accurately estimated by conventional external measurements in high myopic eyes.
METHODS: Ten horizontal anterior segment scans were obtained with the Artemis 1 very high-frequency (VHF) digital ultrasound arc-scanner in 40 eyes of 20 patients. Angle and sulcus diameters were measured and descriptive statistics and within-eye repeatability were calculated. Linear regression was performed between each permutation of white-to-white, angle diameter, and sulcus diameter. Multivariate regression also included anterior chamber depth (ACD), age, manifest refraction, keratometry, and central corneal thickness (CCT). The standard deviation and 95% confidence interval (CI) of the residuals were calculated.
RESULTS: The population mean +/-standard deviation (95% CI) was 12.88 +/- 0.42 mm [12.74, 13.02] for angle diameter and 12.85 +/- 0.69 mm [12.63, 13.07] for sulcus diameter. Within-eye repeatability was 0.13 mm for angle diameter and 0.23 mm for sulcus diameter. A weak correlation was noted between white-to-white and angle diameter (r2=0.59) with a 95% CI of +/-0.53 mm. Multivariate regression found white-to-white, CCT, and minimum keratometry predicted angle diameter (r2=0.69) with a 95% CI of +/-0.46 mm. For predicting sulcus diameter, there were weak correlations between white-to-white (r2=0.32) with a 95% CI of +/-1.11 mm and angle diameter (r2=0.46) with a 95% CI of +/-0.99 mm. Multivariate regression found angle diameter and ACD predicted sulcus diameter (r2=0.57) with 95% CI of +/-0.88 mm.
CONCLUSIONS: Regression modeling found weak correlations among all combinations of white-to-white, angle diameter, and sulcus diameter. Given the relative accuracy of direct measurement of angle and sulcus diameter compared to the potential accuracy of these regression equations, it appears that direct measurement would increase the safety of anterior and posterior chamber phakic intraocular lens sizing.

Entities:  

Mesh:

Year:  2009        PMID: 19241769      PMCID: PMC2649749          DOI: 10.3928/1081597X-20090201-03

Source DB:  PubMed          Journal:  J Refract Surg        ISSN: 1081-597X            Impact factor:   3.573


  27 in total

1.  Correlation between different measurements within the eye relative to phakic intraocular lens implantation.

Authors:  Liliana Werner; Andrea M Izak; Suresh K Pandey; David J Apple; Rupal H Trivedi; Josef M Schmidbauer
Journal:  J Cataract Refract Surg       Date:  2004-09       Impact factor: 3.351

2.  Measurement error.

Authors:  J M Bland; D G Altman
Journal:  BMJ       Date:  1996-09-21

3.  Very high frequency ultrasound analysis of a new phakic posterior chamber intraocular lens in situ.

Authors:  D Y Kim; D Z Reinstein; R H Silverman; D J Najafi; S C Belmont; A P Hatsis; G W Rozakis; D J Coleman
Journal:  Am J Ophthalmol       Date:  1998-05       Impact factor: 5.258

4.  Chronic subclinical inflammation in phakic eyes with intraocular lenses to correct myopia.

Authors:  J J Pérez-Santonja; M T Iradier; J M Benítez del Castillo; J M Serrano; M A Zato
Journal:  J Cataract Refract Surg       Date:  1996-03       Impact factor: 3.351

5.  Lens opacities after posterior chamber phakic intraocular lens implantation.

Authors:  César A Sánchez-Galeana; Ronald J Smith; Donald R Sanders; Francisco X Rodríguez; Sergio Litwak; Miguel Montes; Arturo S Chayet
Journal:  Ophthalmology       Date:  2003-04       Impact factor: 12.079

6.  High-frequency ultrasound measurement of the thickness of the corneal epithelium.

Authors:  D Z Reinstein; R H Silverman; D J Coleman
Journal:  Refract Corneal Surg       Date:  1993 Sep-Oct

7.  U.S. Food and Drug Administration clinical trial of the Implantable Contact Lens for moderate to high myopia.

Authors:  Donald R Sanders; John A Vukich; Kimberley Doney; Monica Gaston
Journal:  Ophthalmology       Date:  2003-02       Impact factor: 12.079

8.  Malignant glaucoma induced by an intraocular lens.

Authors:  J E Reed; J V Thomas; R A Lytle; R J Simmons
Journal:  Ophthalmic Surg       Date:  1990-03

9.  Long-term complications of bilateral posterior chamber phakic intraocular lens implantation.

Authors:  Leonardo Mastropasqua; Lisa Toto; Mario Nubile; Gennaro Falconio; Marco Ciancaglini
Journal:  J Cataract Refract Surg       Date:  2004-04       Impact factor: 3.351

10.  Cataract following posterior chamber phakic intraocular lens.

Authors:  Hisham F El-Sheikh; Khalid F Tabbara
Journal:  J Refract Surg       Date:  2003 Jan-Feb       Impact factor: 3.573

View more
  18 in total

1.  Characteristics of higher-order aberrations and anterior segment tomography in patients with pathologic myopia.

Authors:  Kaori Kasahara; Naoyuki Maeda; Takashi Fujikado; Makoto Tomita; Muka Moriyama; Mutsumi Fuchihata; Kyoko Ohno-Matsui
Journal:  Int Ophthalmol       Date:  2016-11-28       Impact factor: 2.031

2.  Repeatability and agreement of two anterior segment OCT in myopic patients before implantable collamer lenses implantation.

Authors:  Xi-Fang Zhang; Meng Li; Yan Shi; Xiu-Hua Wan; Huai-Zhou Wang
Journal:  Int J Ophthalmol       Date:  2020-04-18       Impact factor: 1.779

3.  Vertical implantable collamer lens (ICL) rotation for the management of high vault due to lens oversizing.

Authors:  Francesco Matarazzo; Alexander Clifford Day; Luis Fernandez-Vega Cueto; Vincenzo Maurino
Journal:  Int Ophthalmol       Date:  2017-11-01       Impact factor: 2.031

4.  Repeatability of layered corneal pachymetry with the artemis very high-frequency digital ultrasound arc-scanner.

Authors:  Dan Z Reinstein; Timothy J Archer; Marine Gobbe; Ronald H Silverman; D Jackson Coleman
Journal:  J Refract Surg       Date:  2009-11-16       Impact factor: 3.573

Review 5.  Meta-analysis and review: effectiveness, safety, and central port design of the intraocular collamer lens.

Authors:  Mark Packer
Journal:  Clin Ophthalmol       Date:  2016-06-09

6.  Buffering zone of implantable Collamer lens sizing in V4c.

Authors:  Seung Wan Nam; Dong Hui Lim; Joo Hyun; Eui-Sang Chung; Tae-Young Chung
Journal:  BMC Ophthalmol       Date:  2017-12-22       Impact factor: 2.209

7.  Three-dimensional non-parametric method for limbus detection.

Authors:  Ahmed Abass; Bernardo T Lopes; Ashkan Eliasy; Richard Wu; Steve Jones; John Clamp; Renato Ambrósio; Ahmed Elsheikh
Journal:  PLoS One       Date:  2018-11-26       Impact factor: 3.240

8.  Adjustment formulae to improve the correlation of white-to-white measurement with direct measurement of the ciliary sulcus diameter by ultrasound biomicroscopy.

Authors:  Seyed Javad Hashemian; Majid Mohebbi; Mehdi Yaseri; Mohammad Ebrahim Jafari; Shadrokh Nabili; Seyed Mahyar Hashemian; Mahsa Sadat Hashemian
Journal:  J Curr Ophthalmol       Date:  2017-12-16

9.  Transscleral fixation of closed loop haptic acrylic posterior chamber intraocular lens in aphakic nonvitrectomized eyes.

Authors:  Siddharth Agrawal; Vinita Singh; Sanjiv Kumar Gupta; Nibha Misra; Rajat M Srivastava
Journal:  Indian J Ophthalmol       Date:  2015-08       Impact factor: 1.848

10.  Ab interno implantation of glaucoma drainage devices tubes in the posterior chamber.

Authors:  Javier Moreno-Montañés; Concepción Guirao-Navarro; Francisco Argüeso
Journal:  BMC Ophthalmol       Date:  2020-02-22       Impact factor: 2.209

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.