PURPOSE: To obtain measurements of the white-to-white distance and the anterior chamber and ciliary sulcus diameters in phakic human eyes obtained post-mortem to find a correlation between these measurements. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Twenty-two phakic human eyes obtained from eye banks within 24 hours of death were evaluated. The following measurements were performed: white-to-white distance, anterior chamber diameter with a plastic sizer after a small limbal incision, and anterior chamber and ciliary sulcus diameters after fixation and sagittal section of the eyes. The first 10 eyes were studied at the 6 o'clock to 12 o'clock meridian and the last 12 eyes, at the 3 o'clock to 9 o'clock meridian. RESULTS: A positive correlation was found between the white-to-white measurements and the anterior chamber diameter in the 10 eyes studied at the 6 o'clock to 12 o'clock meridian but not in the 12 eyes studied at the 3 o'clock to 9 o'clock meridian. The latter is the meridian frequently used by surgeons to perform white-to-white measurements and thus choose the overall size of the phakic intraocular lens to be implanted. No correlation was found between the white-to-white measurements and the ciliary sulcus diameter in the 2 meridians. CONCLUSION: Experimental studies using cadaver eyes are helpful in evaluating sizing techniques for phakic IOL implantation as well as in better understanding the anatomical relationships between ocular structures.
PURPOSE: To obtain measurements of the white-to-white distance and the anterior chamber and ciliary sulcus diameters in phakic human eyes obtained post-mortem to find a correlation between these measurements. SETTING: David J. Apple, MD Laboratories for Ophthalmic Devices Research, John A. Moran Eye Center, University of Utah, Salt Lake City, Utah, USA. METHODS: Twenty-two phakic human eyes obtained from eye banks within 24 hours of death were evaluated. The following measurements were performed: white-to-white distance, anterior chamber diameter with a plastic sizer after a small limbal incision, and anterior chamber and ciliary sulcus diameters after fixation and sagittal section of the eyes. The first 10 eyes were studied at the 6 o'clock to 12 o'clock meridian and the last 12 eyes, at the 3 o'clock to 9 o'clock meridian. RESULTS: A positive correlation was found between the white-to-white measurements and the anterior chamber diameter in the 10 eyes studied at the 6 o'clock to 12 o'clock meridian but not in the 12 eyes studied at the 3 o'clock to 9 o'clock meridian. The latter is the meridian frequently used by surgeons to perform white-to-white measurements and thus choose the overall size of the phakic intraocular lens to be implanted. No correlation was found between the white-to-white measurements and the ciliary sulcus diameter in the 2 meridians. CONCLUSION: Experimental studies using cadaver eyes are helpful in evaluating sizing techniques for phakic IOL implantation as well as in better understanding the anatomical relationships between ocular structures.
Authors: Dan Z Reinstein; Timothy J Archer; Ronald H Silverman; Mark J Rondeau; D Jackson Coleman Journal: J Refract Surg Date: 2009-02 Impact factor: 3.573
Authors: Hassan Hashemi; Mehdi Khabazkhoob; Mohammad Hassan Emamian; Mohammad Shariati; Abbasali Yekta; Akbar Fotouhi Journal: J Curr Ophthalmol Date: 2015-10-19