Literature DB >> 19238389

A method for calcium quantification by means of CT coronary angiography using 64-multidetector CT: very high correlation with Agatston and volume scores.

Bernhard Glodny1, Bettina Helmel, Thomas Trieb, Claudia Schenk, Bernadette Taferner, Verena Unterholzner, Alexander Strasak, Johannes Petersen.   

Abstract

To find out whether calcium scoring of the coronary arteries (CAC scoring) could be carried out with a CT angiography of the coronary arteries (CTCA) in a single CT data acquisition. The Agatston and V130 scores for 113 patients were assessed. A calcium volume score (V600 score) was compiled from the CTCA data sets. Intra- and interobserver correlations were excellent (rho > 0.97). The intra- and interobserver repeatability coefficients were extremely low, increasing in magnitude from the V600 score to the V130 and Agatston scores. The V600 score underestimates the coronary calcium burden. However, it has a linear relation to the Agatston and V130 scores. Thus, they are predictable from the values of the V600 score. The V600 score shows a linear relation to the classic CAC scores. Due to its extremely high reliability, the score may be a feasible alternative for classic CAC scoring methods in order to reduce radiation dosages.

Entities:  

Mesh:

Year:  2009        PMID: 19238389     DOI: 10.1007/s00330-009-1345-2

Source DB:  PubMed          Journal:  Eur Radiol        ISSN: 0938-7994            Impact factor:   5.315


  27 in total

Review 1.  Measuring agreement in method comparison studies.

Authors:  J M Bland; D G Altman
Journal:  Stat Methods Med Res       Date:  1999-06       Impact factor: 3.021

2.  Coronary artery calcium measurement: agreement of multirow detector and electron beam CT.

Authors:  C R Becker; T Kleffel; A Crispin; A Knez; J Young; U J Schoepf; R Haberl; M F Reiser
Journal:  AJR Am J Roentgenol       Date:  2001-05       Impact factor: 3.959

Review 3.  Applying the right statistics: analyses of measurement studies.

Authors:  J M Bland; D G Altman
Journal:  Ultrasound Obstet Gynecol       Date:  2003-07       Impact factor: 7.299

4.  Electron beam CT versus 16-MDCT on the variability of repeated coronary artery calcium measurements in a variable heart rate phantom.

Authors:  Jun Horiguchi; Yun Shen; Yuji Akiyama; Nobuhiko Hirai; Kousuke Sasaki; Minoru Ishifuro; Tadashi Nakanishi; Katsuhide Ito
Journal:  AJR Am J Roentgenol       Date:  2005-10       Impact factor: 3.959

5.  The influence of heart rate, slice thickness, and calcification density on calcium scores using 64-slice multidetector computed tomography: a systematic phantom study.

Authors:  Jaap M Groen; Marcel J Greuter; Bernhard Schmidt; Christoph Suess; Rozemarijn Vliegenthart; Matthijs Oudkerk
Journal:  Invest Radiol       Date:  2007-12       Impact factor: 6.016

6.  Quantification of coronary artery calcium using ultrafast computed tomography.

Authors:  A S Agatston; W R Janowitz; F J Hildner; N R Zusmer; M Viamonte; R Detrano
Journal:  J Am Coll Cardiol       Date:  1990-03-15       Impact factor: 24.094

7.  Coronary calcium scoring using 16-row multislice computed tomography: nonenhanced versus contrast-enhanced studies in vitro and in vivo.

Authors:  Georg Mühlenbruch; Joachim E Wildberger; Ralf Koos; Marco Das; Thomas G Flohr; Matthias Niethammer; Claudia Weiss; Rolf W Günther; Andreas H Mahnken
Journal:  Invest Radiol       Date:  2005-03       Impact factor: 6.016

8.  Reproducibility of dynamic MR imaging pelvic measurements: a multi-institutional study.

Authors:  Mark E Lockhart; Julia R Fielding; Holly E Richter; Linda Brubaker; Caryl G Salomon; Wen Ye; Christiane M Hakim; Clifford Y Wai; Alan H Stolpen; Anne M Weber
Journal:  Radiology       Date:  2008-09-16       Impact factor: 11.105

9.  Statistical methods for assessing agreement between two methods of clinical measurement.

Authors:  J M Bland; D G Altman
Journal:  Lancet       Date:  1986-02-08       Impact factor: 79.321

10.  Coronary artery calcium area by electron-beam computed tomography and coronary atherosclerotic plaque area. A histopathologic correlative study.

Authors:  J A Rumberger; D B Simons; L A Fitzpatrick; P F Sheedy; R S Schwartz
Journal:  Circulation       Date:  1995-10-15       Impact factor: 29.690

View more
  13 in total

1.  Coronary plaque imaging with 256-slice multidetector computed tomography: interobserver variability of volumetric lesion parameters with semiautomatic plaque analysis software.

Authors:  Oliver Klass; Susanne Kleinhans; Matthew J Walker; Mark Olszewski; Sebastian Feuerlein; Markus Juchems; Martin H K Hoffmann
Journal:  Int J Cardiovasc Imaging       Date:  2010-03-26       Impact factor: 2.357

2.  Automatic detection and quantification of the Agatston coronary artery calcium score on contrast computed tomography angiography.

Authors:  Wehab Ahmed; Michiel A de Graaf; Alexander Broersen; Pieter H Kitslaar; Elco Oost; Jouke Dijkstra; Jeroen J Bax; Johan H C Reiber; Arthur J Scholte
Journal:  Int J Cardiovasc Imaging       Date:  2014-08-27       Impact factor: 2.357

3.  Fully automatic model-based calcium segmentation and scoring in coronary CT angiography.

Authors:  Dov Eilot; Roman Goldenberg
Journal:  Int J Comput Assist Radiol Surg       Date:  2013-11-08       Impact factor: 2.924

4.  Correlation between carotid bifurcation calcium burden on non-enhanced CT and percentage stenosis, as confirmed by digital subtraction angiography.

Authors:  B Sarikaya; B Lohman; A M McKinney; S Gadani; M Irfan; L Lucato
Journal:  Br J Radiol       Date:  2011-09-06       Impact factor: 3.039

5.  Radiation dose reduction for coronary artery calcium scoring at 320-detector CT with adaptive iterative dose reduction 3D.

Authors:  Fuminari Tatsugami; Toru Higaki; Wataru Fukumoto; Yoko Kaichi; Chikako Fujioka; Masao Kiguchi; Hideya Yamamoto; Yasuki Kihara; Kazuo Awai
Journal:  Int J Cardiovasc Imaging       Date:  2015-03-10       Impact factor: 2.357

6.  An automated quantification method for the Agatston coronary artery calcium score on coronary computed tomography angiography.

Authors:  Wenjia Wang; Lin Yang; Sicong Wang; Qiong Wang; Lei Xu
Journal:  Quant Imaging Med Surg       Date:  2022-03

7.  CT predictors of post-procedural aortic regurgitation in patients referred for transcatheter aortic valve implantation: an analysis of 105 patients.

Authors:  Mohamed Marwan; Stephan Achenbach; Stefan M Ensminger; Tobias Pflederer; Dieter Ropers; Josef Ludwig; Michael Weyand; Werner G Daniel; Martin Arnold
Journal:  Int J Cardiovasc Imaging       Date:  2013-02-19       Impact factor: 2.357

8.  Atherosclerotic Plaque Burden on Abdominal CT: Automated Assessment With Deep Learning on Noncontrast and Contrast-enhanced Scans.

Authors:  Ronald M Summers; Daniel C Elton; Sungwon Lee; Yingying Zhu; Jiamin Liu; Mohammedhadi Bagheri; Veit Sandfort; Peter C Grayson; Nehal N Mehta; Peter A Pinto; W Marston Linehan; Alberto A Perez; Peter M Graffy; Stacy D O'Connor; Perry J Pickhardt
Journal:  Acad Radiol       Date:  2020-09-18       Impact factor: 3.173

9.  Fully automated derivation of coronary artery calcium scores and cardiovascular risk assessment from contrast medium-enhanced coronary CT angiography studies.

Authors:  Ullrich Ebersberger; Dov Eilot; Roman Goldenberg; Alon Lev; J Reid Spears; Garrett W Rowe; Nicholas Y Gallagher; William T Halligan; Philipp Blanke; Marcus R Makowski; Aleksander W Krazinski; Justin R Silverman; Fabian Bamberg; Alexander W Leber; Ellen Hoffmann; U Joseph Schoepf
Journal:  Eur Radiol       Date:  2012-09-16       Impact factor: 5.315

10.  The association of chronic apical periodontitis and endodontic therapy with atherosclerosis.

Authors:  Johannes Petersen; Eva-Maria Glaßl; Parinaz Nasseri; Adriano Crismani; Anna K Luger; Elisabeth Schoenherr; Kristina Bertl; Bernhard Glodny
Journal:  Clin Oral Investig       Date:  2013-12-12       Impact factor: 3.573

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.