Literature DB >> 16177422

Electron beam CT versus 16-MDCT on the variability of repeated coronary artery calcium measurements in a variable heart rate phantom.

Jun Horiguchi1, Yun Shen, Yuji Akiyama, Nobuhiko Hirai, Kousuke Sasaki, Minoru Ishifuro, Tadashi Nakanishi, Katsuhide Ito.   

Abstract

OBJECTIVE: High reproducibility of coronary artery calcium (CAC) scoring is a key requirement for monitoring the progression of coronary atherosclerosis. The purposes of this study were to compare electron beam CT and 16-MDCT scanners in the variability of repeated CAC measurements and to assess the factors influencing this variability.
MATERIALS AND METHODS: CAC models of different sizes attached to a cardiac phantom with a programmable variable heart rate were scanned three times, and interscan variability of the CAC measurement was calculated each time. For helical CT, different slice-thickness images of either retrospective ECG-gated or prospective ECG-triggering reconstruction were obtained. The detection of small amounts of calcium, variability of the Agatston score, and CAC measurement algorithms (Agatston, volume, and mass scores) were compared between CT scanners and protocols.
RESULTS: All 1-mm-sized calcium models were detected on 0.625- and 1.25-mm helical CT, whereas some were missed on electron beam CT and 2.5-mm helical CT. Retrospective ECG-gated thin-slice helical CT showed the lowest variability. Reduction of variability by volume and mass scoring algorithms was less effective on 0.625- and 1.25-mm-thickness CT.
CONCLUSION: Retrospective ECG-gated thin-slice helical CT has the potential to be a useful tool for monitoring coronary atherosclerosis.

Entities:  

Mesh:

Year:  2005        PMID: 16177422     DOI: 10.2214/AJR.04.1057

Source DB:  PubMed          Journal:  AJR Am J Roentgenol        ISSN: 0361-803X            Impact factor:   3.959


  7 in total

1.  A method for calcium quantification by means of CT coronary angiography using 64-multidetector CT: very high correlation with Agatston and volume scores.

Authors:  Bernhard Glodny; Bettina Helmel; Thomas Trieb; Claudia Schenk; Bernadette Taferner; Verena Unterholzner; Alexander Strasak; Johannes Petersen
Journal:  Eur Radiol       Date:  2009-02-24       Impact factor: 5.315

Review 2.  CT for assessing ventricular remodeling: is it ready for prime time?

Authors:  Gardar Sigurdsson
Journal:  Curr Heart Fail Rep       Date:  2008-03

3.  Coronary artery calcification scores in patients with chronic kidney disease prior to dialysis: reliability as a trial outcome measure.

Authors:  Katherine A Barraclough; Lesley A Stevens; Lee Er; Debbie Rosenbaum; Jacqueline Brown; Pari Tiwari; Adeera Levin
Journal:  Nephrol Dial Transplant       Date:  2008-05-01       Impact factor: 5.992

4.  Calcium scoring using 64-slice MDCT, dual source CT and EBT: a comparative phantom study.

Authors:  Jaap M Groen; Marcel J W Greuter; R Vliegenthart; C Suess; B Schmidt; F Zijlstra; M Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2007-11-23       Impact factor: 2.357

5.  Evaluation of the influence of acquisition and reconstruction parameters for 16-row multidetector CT on coronary calcium scoring using a stationary and dynamic cardiac phantom.

Authors:  Philipp G C Begemann; Udo van Stevendaal; Ralph Koester; Andreas H Mahnken; Andreas Koops; Gerhard Adam; Michael Grass; Claus Nolte-Ernsting
Journal:  Eur Radiol       Date:  2007-02-01       Impact factor: 7.034

6.  Dissociation between progression of coronary artery calcification and endothelial function in hemodialysis patients: a prospective pilot study.

Authors:  Roberto S Kalil; Michael Flanigan; William Stanford; William G Haynes
Journal:  Clin Nephrol       Date:  2012-07       Impact factor: 0.975

7.  Coronary calcium mass scores measured by identical 64-slice MDCT scanners are comparable: a cardiac phantom study.

Authors:  Hildebrand Dijkstra; Marcel J W Greuter; Jaap M Groen; Rozemarijn Vliegenthart-Proença; Klaasjan W K Renema; Frank de Lange; Matthijs Oudkerk
Journal:  Int J Cardiovasc Imaging       Date:  2009-09-19       Impact factor: 2.357

  7 in total

北京卡尤迪生物科技股份有限公司 © 2022-2023.