Literature DB >> 19235919

Double half RF pulses for reduced sensitivity to eddy currents in UTE imaging.

Sonal Josan1, John M Pauly, Bruce L Daniel, Kim Butts Pauly.   

Abstract

Ultrashort echo time imaging with half RF pulse excitation is challenging as eddy currents induced by the slice-select gradient distort the half pulse slice profile. This work presents two pulses with T(2)-dependent slice profiles that are less sensitive to eddy currents. The double half pulse improves the slice selectivity for long T(2) components, while the inverted double half pulse suppresses the unwanted long T(2) signal. Thus, both approaches prevent imperfect cancellation of out-of-slice signal from contaminating the desired slice. Experimental results demonstrate substantially improved slice selectivity and R(2)* quantitation accuracy with these pulses. These pulses are effective in making short T(2) imaging and quantitation less sensitive to eddy currents and provide an alternative to time-consuming gradient characterization. (c) 2009 Wiley-Liss, Inc.

Mesh:

Year:  2009        PMID: 19235919     DOI: 10.1002/mrm.21879

Source DB:  PubMed          Journal:  Magn Reson Med        ISSN: 0740-3194            Impact factor:   4.668


  16 in total

1.  Review. The Agfa Mayneord lecture: MRI of short and ultrashort T₂ and T₂* components of tissues, fluids and materials using clinical systems.

Authors:  G M Bydder
Journal:  Br J Radiol       Date:  2011-12       Impact factor: 3.039

2.  MR imaging to assess immediate response to irreversible electroporation for targeted ablation of liver tissues: preclinical feasibility studies in a rodent model.

Authors:  Yue Zhang; Yang Guo; Ann B Ragin; Robert J Lewandowski; Guang-Yu Yang; Grace M Nijm; Alan V Sahakian; Reed A Omary; Andrew C Larson
Journal:  Radiology       Date:  2010-08       Impact factor: 11.105

Review 3.  Quantitative magnetic resonance imaging of the lumbar intervertebral discs.

Authors:  Dosik Hwang; Sewon Kim; Nirusha A Abeydeera; Sheronda Statum; Koichi Masuda; Christine B Chung; Palanan Siriwanarangsun; Won C Bae
Journal:  Quant Imaging Med Surg       Date:  2016-12

4.  DQF-MT MRI of connective tissues: application to tendon and muscle.

Authors:  Slawomir Kusmia; Uzi Eliav; Gil Navon; Geneviève Guillot
Journal:  MAGMA       Date:  2012-09-23       Impact factor: 2.310

5.  30-Second bound and pore water concentration mapping of cortical bone using 2D UTE with optimized half-pulses.

Authors:  Mary Kate Manhard; Kevin D Harkins; Daniel F Gochberg; Jeffry S Nyman; Mark D Does
Journal:  Magn Reson Med       Date:  2017-01-16       Impact factor: 4.668

6.  Quantitative ultrashort echo time imaging for assessment of massive iron overload at 1.5 and 3 Tesla.

Authors:  Axel J Krafft; Ralf B Loeffler; Ruitian Song; Aaryani Tipirneni-Sajja; M Beth McCarville; Matthew D Robson; Jane S Hankins; Claudia M Hillenbrand
Journal:  Magn Reson Med       Date:  2017-01-16       Impact factor: 4.668

7.  Clinically compatible MRI strategies for discriminating bound and pore water in cortical bone.

Authors:  R Adam Horch; Daniel F Gochberg; Jeffry S Nyman; Mark D Does
Journal:  Magn Reson Med       Date:  2012-01-31       Impact factor: 4.668

8.  Simple and robust saturation-based slice selection for ultrashort echo time MRI.

Authors:  Kevin D Harkins; R Adam Horch; Mark D Does
Journal:  Magn Reson Med       Date:  2014-07-09       Impact factor: 4.668

9.  Consistency of signal intensity and T2* in frozen ex vivo heart muscle, kidney, and liver tissue.

Authors:  Elena A Kaye; Sonal Josan; Aiming Lu; Jarrett Rosenberg; Bruce L Daniel; Kim Butts Pauly
Journal:  J Magn Reson Imaging       Date:  2010-03       Impact factor: 4.813

10.  Radiofrequency phase encoded half-pulses in simultaneous multislice ultrashort echo time imaging.

Authors:  Christoph Rettenmeier; V Andrew Stenger
Journal:  Magn Reson Med       Date:  2019-02-12       Impact factor: 4.668

View more

北京卡尤迪生物科技股份有限公司 © 2022-2023.